Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#447590 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID447590
FacilityTypeOGProj Number
CountyJACKSON - 057LocationLot 4 18 7N80W
Elevation8207Lat/Long40.571458/-106.424656
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-057-06584Well Name:Peters 0781 9-13H12
Well Status:PROperator Name:FULCRUM ENERGY OPERATING LLC
Location:LOT4  18 7N  80W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   645668     Sample Date:  12/20/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 645668    Dolan Integration Group ID: DIG-030589
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS13BTU/cuft
SOPBUTANE0.052MOL %0.005
SOPC6+ (hexanes +)0.012MOL %0.005
SOPCARBON DIOXIDE0.107MOL %0.005
SOPDELTA 13C C1-55.3per mil
SOPDELTA D C1-258per mil
SOPETHANE0.042MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.012MOL %0.005
SOPISOPENTANE0.018MOL %0.005
SOPMETHANE0.572MOL %0.005
SOPNITROGEN (N2)79.883MOL %0.005
SOPOXYGEN + ARGON19.239MOL %0.005
SOPPENTANE0.017MOL %0.005
SOPPROPANE0.047MOL %0.005
SOPSPECIFIC GRAVITY0.993No Unit

 Sample ID:   645930     Sample Date:  12/13/2022     Matrix:  GAS     Collection Point:  SEP     Type:  PCS     Lab:  SPL

Sample Results for Sample # 645930    SPL ID: 22120128-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.0014MOL %
GPA 2286BENZENE0.0065MOL %
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1147.7BTU/cuft
GPA 2286BUTANE1.3353MOL %
GPA 2286C11 (mixed isomers)MOL %
GPA 2286C12 (mixed isomers)MOL %
GPA 2286C13 (mixed isomers)MOL %
GPA 2286CARBON DIOXIDE2.1103MOL %
GPA 2286CYCLOHEXANE0.0218MOL %
GPA 2286Decane0.0004MOL %
GPA 2286Decanes (mixed isomers)MOL %
GPA 2286ETHENE4.9029MOL %
GPA 2286ETHYLBENZENE0.0011MOL %
GPA 2286Heptane0.0172MOL %
GPA 2286ISOBUTANE0.3709MOL %
GPA 2286ISOPENTANE0.2469MOL %
GPA 2286METHANE84.4696MOL %
GPA 2286N-HEXANE0.0562MOL %
GPA 2286n-octane0.0035MOL %
GPA 2286NITROGEN (N2)1.6739MOL %
GPA 2286NONANE0.0007MOL %
GPA 2286Other Heptanes0.1163MOL %
GPA 2286Other Hexanes0.0949MOL %
GPA 2286Other Nonanes0.0027MOL %
GPA 2286Other Octanes0.0388MOL %
GPA 2286PENTANE0.2711MOL %
GPA 2286PROPANE4.2438MOL %
GPA 2286SPECIFIC GRAVITY0.6925RATIO_AIR
GPA 2286Tetradecanes +MOL %
GPA 2286TOLUENE0.0054MOL %
GPA 2286TOTAL XYLENES0.0022MOL %

 Sample ID:   656928     Sample Date:  11/22/2023     Matrix:  WATER     Collection Point:  SEP     Type:  SEP     Lab:  

Sample Results for Sample # 656928 ID: 350037
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E170.1Sample Temperature70degrees F
E200.7ALUMINUM0.07mg/L
E200.7AMMONIA0mg/L
E200.7BARIUM62.25mg/L
E200.7CALCIUM236.05mg/L
E200.7IRON79.19mg/L
E200.7LEAD0mg/L
E200.7LITHIUM1.96mg/L
E200.7MAGNESIUM31.36mg/L
E200.7MANGANESE1.11mg/L
E200.7POTASSIUM25.75mg/L
E200.7SODIUM17327mg/L
E200.7STRONTIUM39.25mg/L
E200.7ZINC0.09mg/L
E200.8TOTAL DISSOLVED SOLIDS, CALCULATED LAB46749mg/L
E300.0ACETIC ACID0mg/L
E300.0BICARBONATE ALKALINITY as CACO3707.6mg/L as CaCO3
E300.0BORON8.9mg/L
E300.0BROMIDE0mg/L
E300.0CARBON DIOXIDE310mg/L
E300.0CARBONATE ALKALINITY AS CACO30mg/L as CaCO3
E300.0CHLORIDE27000mg/L
E300.0FLUORIDE0mg/L
E300.0HYDROGEN SULFIDE1.7mg/L
E300.0NITRATE0mg/L
E300.0PHOSPHATE0mg/L
E300.0SILICA (SiO2)0mg/L
E300.0SULFATE25mg/L
SM2510BRESISTIVITY18.23ohm/M
SM2510BSPECIFIC CONDUCTIVITY54862uS/cm
SM2710FSPECIFIC GRAVITY1.028RATIO_AIR
SM4500-H+ BPH, LAB6.53pH Units
SOPPRESSURE0.0156PSIG
SOPPRESSURE1.69PSIG
SOPPRESSURE14.6959PSIG

 Sample ID:   613918     Sample Date:  09/23/2019     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 613918    SPL ID: 19100025-004A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.001MOL %
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1204.4BTU/cuft
GPA 2286BUTANE1.956MOL %
GPA 2286C11 (mixed isomers)0.012MOL %
GPA 2286CARBON DIOXIDE2.299MOL %
GPA 2286Decane0.002MOL %
GPA 2286Decanes (mixed isomers)0.018MOL %
GPA 2286ETHANE5.073MOL %
GPA 2286HEPTANES, MIXED ISOMERS0.031MOL %
GPA 2286ISOBUTANE0.525MOL %
GPA 2286ISOPENTANE0.429MOL %
GPA 2286METHANE81.741MOL %
GPA 2286N-HEXANE0.112MOL %
GPA 2286n-octane0.005MOL %
GPA 2286NITROGEN (N2)1.797MOL %
GPA 2286NONANE0.005MOL %
GPA 2286Other Heptanes0.212MOL %
GPA 2286Other Hexanes0.2MOL %
GPA 2286Other Nonanes0.048MOL %
GPA 2286Other Octanes0.102MOL %
GPA 2286PENTANE0.483MOL %
GPA 2286PROPANE4.942MOL %
GPA 2286SPECIFIC GRAVITY0.7334RATIO_AIR
GPA 2286TOTAL XYLENES0.008MOL %

 Sample ID:   620275     Sample Date:  09/09/2020     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 620275    SPL ID: 20090118-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1186.6BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1207.7BTU/cuft dry
GPA 2261-13BUTANE2.073MOL %
GPA 2261-13C6+ (hexanes +)0.5012MOL %
GPA 2261-13CARBON DIOXIDE2.3278MOL %
GPA 2261-13ETHANE5.1307MOL %
GPA 2261-13ISOBUTANE0.5432MOL %
GPA 2261-13ISOPENTANE0.4509MOL %
GPA 2261-13METHANE81.458MOL %
GPA 2261-13NITROGEN (N2)1.6914MOL %
GPA 2261-13PENTANE0.3028MOL %
GPA 2261-13PROPANE5.1286MOL %
GPA 2261-13SPECIFIC GRAVITY0.735Ratio

 Sample ID:   667163     Sample Date:  07/24/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667163    American Mobile Research ID: CR-53
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.034MOL %
GPA 2286Avg Molecular Weight21.8111gm/mole
GPA 2286BENZENE0.02MOL %
GPA 2286BRITISH THERMAL UNITS - SATURATED BASIS1209.82BTU
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1230.98BTU
GPA 2286BUTANE2.189MOL %
GPA 2286CARBON DIOXIDE2.781MOL %
GPA 2286COMPRESSIBILITY0.996323No Unit
GPA 2286CYCLOHEXANE0.068MOL %
GPA 2286CYCLOPENTANE0.036MOL %
GPA 2286DECANES +0.006MOL %
GPA 2286ETHENE5.429MOL %
GPA 2286ETHYLBENZENE0.001MOL %
GPA 2286HEPTANES, MIXED ISOMERS0.263MOL %
GPA 2286HYDROGEN SULFIDE0MOL %
GPA 2286ISOBUTANE0.539MOL %
GPA 2286ISOPENTANE0.507MOL %
GPA 2286METHANE80.091MOL %
GPA 2286METHYL CYCLOHEXANE0.041MOL %
GPA 2286N-HEXANE0.217MOL %
GPA 2286NITROGEN (N2)1.538MOL %
GPA 2286NONANE0.003MOL %
GPA 2286OCTANE, MIXED ISOMERS0.023MOL %
GPA 2286Other Hexanes0.328MOL %
GPA 2286PENTANE0.606MOL %
GPA 2286PROPANE5.264MOL %
GPA 2286Relative Density (air = 1)0.755854Ratio
GPA 2286SPECIFIC GRAVITY0.753074RATIO_AIR
GPA 2286TOLUENE0.011MOL %
GPA 2286Total non gas liquids GPM4.60305gal/MCF
GPA 2286TOTAL XYLENES0.005MOL %

 Sample ID:   667164     Sample Date:  07/24/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667164    American Mobile Research ID: CR-54
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
ASTM D5504CARBON DISULFIDENDmg/L<
ASTM D5504HYDROGEN SULFIDE3.13mg/L
ASTM D5504Sulfur DioxideNDmg/L<

 Sample ID:   661558     Sample Date:  07/24/2024     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 661558    Dolan Integration Group ID: DIG-036357
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %0.514%
CALCcarbon preference index (Hunt)0.952Ratio
CALCcarbon preference index (Marzi)0.873Ratio
CALCcycloparaffins %0.552%
CALCisoparaffins % (branched)0.519%
CALCisoprenoids %7.22%
CALCn paraffin %25.996%
CALCnC17/(nC18+nC29) ratio1Ratio
CALCnC18/(nC18+nC19) ratio0.576Ratio
CALCphytane/nC18 ratio0.496Ratio
CALCpristane/nC17 ratio0.532Ratio
CALCpristane/phytane ratio1.389Ratio
CALCresolved unknowns %63.005%
G02G1,1,3-TrimethylcyclopentaneNDAREA COUNT1ND
G02G1,1,3-TrimethylcyclopentaneNDppm10ND
G02G1,1-dimethylcyclopentaneNDAREA COUNT1ND
G02G1,1-dimethylcyclopentaneNDppm10ND
G02G1,2,3-trimethylcyclopentane1.036AREA COUNT1
G02G1,2,3-trimethylcyclopentane86ppm10
G02G1,2,4-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,4-trimethylcyclopentaneNDppm10ND
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentane0.086AREA COUNT1
G02G2,2-dimethylpentane7ppm10
G02G2,3-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,3-DIMETHYLBUTANENDppm10ND
G02G2,3-dimethylpentane0.627AREA COUNT1
G02G2,3-dimethylpentane51ppm10
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-methylhexane1.18AREA COUNT1
G02G2-methylhexane96ppm10
G02G2-METHYLPENTANENDAREA COUNT1ND
G02G2-METHYLPENTANENDppm10ND
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane1.715AREA COUNT1
G02G3-methylhexane139ppm10
G02G3-METHYLPENTANENDAREA COUNT1ND
G02G3-METHYLPENTANENDppm10ND
G02GBENZENENDAREA COUNT1ND
G02GBENZENENDppm10ND
G02GBUTANE2.215AREA COUNT1
G02GBUTANE177ppm10
G02Gcis-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gcis-1,3-dimethylcyclopentaneNDppm10ND
G02GCYCLOHEXANE2.576AREA COUNT1
G02GCYCLOHEXANE213ppm10
G02GCYCLOPENTANENDAREA COUNT1ND
G02GCYCLOPENTANENDppm10ND
G02GDecane114.815AREA COUNT1
G02GDecane9362ppm10
G02GETHYLBENZENE4.437AREA COUNT1
G02GETHYLBENZENE356ppm10
G02Gethylcyclopentane1.111AREA COUNT1
G02Gethylcyclopentane92ppm10
G02GHeptane3.226AREA COUNT1
G02GHeptane261ppm10
G02GHEXANES1.371AREA COUNT1
G02GHEXANES111ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANENDAREA COUNT1ND
G02GISOBUTANENDppm10ND
G02GISOPENTANENDAREA COUNT1ND
G02GISOPENTANENDppm10ND
G02Gisoprenoid C1019.892AREA COUNT1
G02Gisoprenoid C101622ppm10
G02Gisoprenoid C1142.84AREA COUNT1
G02Gisoprenoid C113497ppm10
G02Gisoprenoid C1378.673AREA COUNT1
G02Gisoprenoid C136435ppm10
G02Gisoprenoid C1457.088AREA COUNT1
G02Gisoprenoid C144674ppm10
G02Gisoprenoid C1544.643AREA COUNT1
G02Gisoprenoid C153659ppm10
G02Gisoprenoid C1654.708AREA COUNT1
G02Gisoprenoid C164484ppm10
G02Gisoprenoid C1852.078AREA COUNT1
G02Gisoprenoid C184272ppm10
G02Gisoprenoid C94.333AREA COUNT1
G02Gisoprenoid C9353ppm10
G02Gm-XYLENE10.867AREA COUNT1
G02Gm-XYLENE865ppm10
G02GMETHYL CYCLOHEXANE10.479AREA COUNT1
G02GMETHYL CYCLOHEXANE867ppm10
G02GMETHYLCYCLOPENTANE1.794AREA COUNT1
G02GMETHYLCYCLOPENTANE148ppm10
G02Gn-C11260.375AREA COUNT1
G02Gn-C1121253ppm10
G02Gn-C12222.019AREA COUNT1
G02Gn-C1218140ppm10
G02Gn-C13184.658AREA COUNT1
G02Gn-C1315103ppm10
G02Gn-C14150.39AREA COUNT1
G02Gn-C1412313ppm10
G02Gn-C15126.725AREA COUNT1
G02Gn-C1510386ppm10
G02Gn-C16114.805AREA COUNT1
G02Gn-C169409ppm10
G02Gn-C17104.598AREA COUNT1
G02Gn-C178581ppm10
G02Gn-C1880.879AREA COUNT1
G02Gn-C186635ppm10
G02Gn-C1959.566AREA COUNT1
G02Gn-C194887ppm10
G02Gn-C2054.288AREA COUNT1
G02Gn-C204458ppm10
G02Gn-C2133.009AREA COUNT1
G02Gn-C212711ppm10
G02Gn-C2223.773AREA COUNT1
G02Gn-C221953ppm10
G02Gn-C2314.392AREA COUNT1
G02Gn-C231183ppm10
G02Gn-C249.669AREA COUNT1
G02Gn-C24795ppm10
G02Gn-C254.161AREA COUNT1
G02Gn-C25342ppm10
G02Gn-C262.742AREA COUNT1
G02Gn-C26226ppm10
G02Gn-C271.737AREA COUNT1
G02Gn-C27143ppm10
G02Gn-C281.33AREA COUNT1
G02Gn-C28109ppm10
G02Gn-C29NDAREA COUNT1ND
G02Gn-C29NDppm10ND
G02Gn-C300.64AREA COUNT1
G02Gn-C3053ppm10
G02Gn-C310.591AREA COUNT1
G02Gn-C3149ppm10
G02Gn-c32NDAREA COUNT1ND
G02Gn-c32NDppm10ND
G02Gn-C33NDAREA COUNT1ND
G02Gn-C33NDppm10ND
G02Gn-C34NDAREA COUNT1ND
G02Gn-C34NDppm10ND
G02Gn-C35NDAREA COUNT1ND
G02Gn-C35NDppm10ND
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane9.196AREA COUNT1
G02Gn-octane747ppm10
G02GNormal Alkane C938.325AREA COUNT1
G02GNormal Alkane C93119ppm10
G02Go-XYLENE8.044AREA COUNT1
G02Go-XYLENE652ppm10
G02Gp-XYLENE3.834AREA COUNT1
G02Gp-XYLENE317ppm10
G02GPENTANE0.961AREA COUNT1
G02GPENTANE77ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane40.099AREA COUNT1
G02Gphytane3293ppm10
G02Gpristane55.683AREA COUNT1
G02Gpristane4568ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE4.856AREA COUNT1
G02GTOLUENE375ppm10
G02Gtrans-1,2-dimethylcyclopentane1.369AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane113ppm10
G02Gtrans-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,3-dimethylcyclopentaneNDppm10ND

 Sample ID:   606789     Sample Date:  05/14/2019     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 606789    SPL ID: 2500-19050080-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDHYDROGEN SULFIDE, FIELD25ppm
GPA 2172BRITISH THERMAL UNITS - SATURATED BASIS1368.1BTU
GPA 2172BRITISH THERMAL UNITS- DRY BASIS1392.3BTU
GPA 2172Relative Density (air = 1)0.8515Ratio
GPA 22862,2,4-Trimethylpentane0.003MOL %
GPA 22862-methylhexane0.275MOL %
GPA 22862-methyloctane0.014MOL %
GPA 22862-METHYLPENTANE0.318MOL %
GPA 2286BENZENE0.02MOL %
GPA 2286BUTANE3.84MOL %
GPA 2286CARBON DIOXIDE2.567MOL %
GPA 2286CYCLOHEXANE0.052MOL %
GPA 2286DECANES +0.004MOL %
GPA 2286ETHANE8.247MOL %
GPA 2286ETHYLBENZENE0.003MOL %
GPA 2286Heptane0.041MOL %
GPA 2286ISOBUTANE1.068MOL %
GPA 2286ISOPENTANE0.787MOL %
GPA 2286METHANE70.692MOL %
GPA 2286N-HEXANE0.17MOL %
GPA 2286n-octane0.012MOL %
GPA 2286NITROGEN (N2)1.126MOL %
GPA 2286NONANE0.002MOL %
GPA 2286Other Octanes0.104MOL %
GPA 2286PENTANE0.847MOL %
GPA 2286PROPANE9.789MOL %
GPA 2286TOLUENE0.014MOL %
GPA 2286TOTAL XYLENES0.005MOL %

 Sample ID:   667492     Sample Date:  04/24/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 667492    Pace Analytical ID: L1851796-03
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E365.4PHOSPHORUS0.177mg/L0.1
RSK-175ETHANE1.2mg/L0.013
RSK-175ETHENENDmg/L0.013U
RSK-175METHANE4.81mg/L0.01
SM2320BBICARBONATE ALKALINITY as CACO3619mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L20U
SM2320BTOTAL ALKALINITY AS CACO3619mg/L20
SM2540CTOTAL DISSOLVED SOLIDS56800mg/L1000
SM2540DTOTAL SUSPENDED SOLIDS75.6mg/L6.95
SM4500-P-EORTHOPHOSPHATE0.173mg/L0.03
SW6010BARIUM123mg/L0.025
SW6010BORON17mg/L1
SW6010CALCIUM450mg/L5
SW6010IRON20.5mg/L0.5
SW6010MAGNESIUM58.3mg/L5
SW6010MANGANESE0.304mg/L0.05
SW6010POTASSIUM57.3mg/L10
SW6010SELENIUMNDmg/L0.05U
SW6010SODIUM14700mg/L60
SW6010STRONTIUM75mg/L0.05
SW8015C10-C28 Diesel Range Organics12.1mg/L0.5
SW8015C28-C36 Motor Oil Range Organics6.32mg/L0.5
SW8015TVPH - Gasoline Range Organics31.9mg/L2.5
SW846 8260BBENZENE6.52mg/L0.5
SW846 8260BETHYLBENZENENDmg/L0.5U
SW846 8260BNAPHTHALENENDmg/L2.5U
SW846 8260BTOLUENE5.28mg/L0.5
SW846 8260BTOTAL XYLENESNDmg/L1.5U
SW9040PH, LAB6.54SUT8
SW9050SPECIFIC CONDUCTIVITY62000umhos/cm10
SW9056BROMIDE327mg/L50
SW9056CHLORIDE24700mg/L500
SW9056FLUORIDENDmg/L7.5U
SW9056NITRATENDmg/L5U
SW9056NITRITENDmg/L5U
SW9056SULFATENDmg/L250U

 Sample ID:   667491     Sample Date:  04/24/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 667491    Pace Analytical ID: L1851797-03
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E904.0228RADIUM25.6pCi/L0.397
SM7500-RN-B226RADIUM64.1pCi/L0.177