Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#437773 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID437773
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSW 36 3N68W
Elevation4818Lat/Long40.176604/-104.958129
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-39683Well Name:VOGL 34N-35HZ
Well Status:PROperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSW  36 3N  68W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   629270     Sample Date:  08/04/2021     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 629270    Dolan Integration Group ID: DIG-025915
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1205BTU/cuft
SOPBUTANE0.99MOL %0.005
SOPC6+ (hexanes +)0.327MOL %0.005
SOPCARBON DIOXIDE1.597MOL %0.005
SOPDELTA 13C C1-49.6per mil
SOPDELTA 13C C2-33.9per mil
SOPDELTA 13C C3-30.4per mil
SOPDELTA 13C nC4-31.5per mil
SOPDELTA D C1-254per mil
SOPETHANE12.352MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.022MOL %0.005
SOPHYDROGEN0.126MOL %0.005
SOPISOBUTANE0.503MOL %0.005
SOPISOPENTANE0.072MOL %0.005
SOPMETHANE78.434MOL %0.005
SOPNITROGEN (N2)0.607MOL %0.005
SOPOXYGEN + ARGON0.026MOL %0.005
SOPPENTANE0.089MOL %0.005
SOPPROPANE4.854MOL %0.005
SOPSPECIFIC GRAVITY0.712No Unit

 Sample ID:   629269     Sample Date:  08/04/2021     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 629269    Dolan Integration Group ID: DIG-025914
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1100BTU/cuft
SOPBUTANE0.781MOL %0.005
SOPC6+ (hexanes +)0.207MOL %0.005
SOPCARBON DIOXIDE0.008MOL %0.005
SOPDELTA 13C C1-53.2per mil
SOPDELTA 13C C2-34.9per mil
SOPDELTA 13C C3-30.7per mil
SOPDELTA 13C nC4-31per mil
SOPDELTA D C1-256per mil
SOPETHANE7.66MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.057MOL %0.005
SOPHYDROGEN0.539MOL %0.005
SOPISOBUTANE0.452MOL %0.005
SOPISOPENTANE0.177MOL %0.005
SOPMETHANE79.885MOL %0.005
SOPNITROGEN (N2)5.676MOL %0.005
SOPOXYGEN + ARGON0.921MOL %0.005
SOPPENTANE0.145MOL %0.005
SOPPROPANE3.493MOL %0.005
SOPSPECIFIC GRAVITY0.683No Unit

 Sample ID:   653171     Sample Date:  08/03/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 653171    ISOTECH ID: 884517
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.172MOL %0.005
SOPBRITISH THERMAL UNITS960BTU
SOPBUTANE0.608MOL %0.0001
SOPC6+ (hexanes +)0.0953MOL %0.0001
SOPCARBON DIOXIDE0.029MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-53.3
SOPDELTA 13C C2-34.4
SOPDELTA 13C C3-30.1
SOPDELTA 13C iC4-31.7
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-28.4
SOPDelta 13C nC5-27.9
SOPDELTA D C1-250
SOPETHANE6.87MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0288MOL %0.005
SOPHYDROGEN0.312MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.356MOL %0.0001
SOPISOPENTANE0.136MOL %0.0001
SOPMETHANE70.51MOL %0.0002
SOPNITROGEN (N2)14.12MOL %0.01
SOPOXYGEN (O2)3.66MOL %0.01
SOPPENTANE0.106MOL %0.0001
SOPPROPANE3MOL %0.0001
SOPPROPENE0.0002MOL %0.0001
SOPSPECIFIC GRAVITY0.716RATIO_AIR

 Sample ID:   653172     Sample Date:  08/03/2023     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 653172    ISOTECH ID: 884516
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1215BTU
SOPBUTANE1.01MOL %0.0001
SOPC6+ (hexanes +)0.261MOL %0.0001
SOPCARBON DIOXIDE1.38MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-50.3
SOPDELTA 13C C2-33
SOPDELTA 13C C3-29.5
SOPDELTA 13C CO21.2
SOPDELTA 13C iC4-31.6
SOPDelta 13C iC5-27.9
SOPDELTA 13C nC4-27.9
SOPDelta 13C nC5-27.6
SOPDELTA D C1-249
SOPETHANE12.33MOL %0.0001
SOPETHENE0.0034MOL %0.0001
SOPHelium0.0137MOL %0.005
SOPHYDROGEN0.248MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.499MOL %0.0001
SOPISOPENTANE0.147MOL %0.0001
SOPMETHANE78.61MOL %0.0002
SOPNITROGEN (N2)0.49MOL %0.01
SOPOXYGEN (O2)0.017MOL %0.01
SOPPENTANE0.166MOL %0.0001
SOPPROPANE4.82MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.709RATIO_AIR

 Sample ID:   671379     Sample Date:  07/17/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 671379    ISOTECH ID: 976681
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0188MOL %0.005
SOPBRITISH THERMAL UNITS1150BTU
SOPBUTANE0.802MOL %0.0001
SOPC6+ (hexanes +)0.102MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-52.4
SOPDELTA 13C C2-34.2
SOPDELTA 13C C3-29.9
SOPDELTA 13C iC4-32
SOPDelta 13C iC5-28.5
SOPDELTA 13C nC4-28.6
SOPDelta 13C nC5-27.8
SOPDELTA D C1-251
SOPETHANE8.21MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0397MOL %0.0025
SOPHYDROGEN0.462MOL %0.0025
SOPISOBUTANE0.489MOL %0.0001
SOPISOPENTANE0.183MOL %0.0001
SOPMETHANE83.56MOL %0.0002
SOPNITROGEN (N2)2.11MOL %0.01
SOPOXYGEN (O2)0.13MOL %0.01
SOPPENTANE0.14MOL %0.0001
SOPPROPANE3.75MOL %0.0001
SOPPROPENE0.0002MOL %0.0001
SOPSPECIFIC GRAVITY0.665RATIO_AIR

 Sample ID:   671380     Sample Date:  07/17/2025     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 671380    ISOTECH ID: 976680
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1243BTU
SOPBUTANE1.45MOL %0.0001
SOPC6+ (hexanes +)0.154MOL %0.0001
SOPCARBON DIOXIDE1.61MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.8
SOPDELTA 13C C2-33.6
SOPDELTA 13C C3-29.5
SOPDELTA 13C CO22.1
SOPDELTA 13C iC4-31.8
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-28.4
SOPDelta 13C nC5-27.5
SOPDELTA D C1-250
SOPETHANE12.96MOL %0.0001
SOPETHENE0.0018MOL %0.0001
SOPHelium0.0119MOL %0.0025
SOPHYDROGEN0.176MOL %0.0025
SOPISOBUTANE0.628MOL %0.0001
SOPISOPENTANE0.264MOL %0.0001
SOPMETHANE76.36MOL %0.0002
SOPNITROGEN (N2)0.53MOL %0.01
SOPOXYGEN (O2)0.073MOL %0.01
SOPPENTANE0.282MOL %0.0001
SOPPROPANE5.49MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.732RATIO_AIR

 Sample ID:   606129     Sample Date:  03/05/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 606129    ISOTECH ID: 707510
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1105BTU
SOPBUTANE0.0052MOL %0.0001
SOPC6+ (hexanes +)0.0059MOL %0.0001
SOPCARBON DIOXIDE1.55MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.62
SOPDELTA 13C C2-33.23
SOPDELTA 13C C3-27.07
SOPDELTA 13C CO21.67
SOPDELTA D C1-251.4
SOPETHANE13.23MOL %0.0001
SOPETHENE0.0111MOL %0.0001
SOPHelium0.0149MOL %0.005
SOPHYDROGEN0.287MOL %0.01
SOPISOBUTANE0.0019MOL %0.0001
SOPISOPENTANE0.0021MOL %0.0001
SOPMETHANE83.62MOL %0.0002
SOPNITROGEN (N2)0.51MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.0029MOL %0.0001
SOPPROPANE0.758MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.641RATIO_AIR

 Sample ID:   606128     Sample Date:  03/05/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 606128    ISOTECH ID: 707511
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.041MOL %0.005
SOPBRITISH THERMAL UNITS1111BTU
SOPBUTANE0.844MOL %0.0001
SOPC6+ (hexanes +)0.0233MOL %0.0001
SOPCARBON DIOXIDE0.009MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-51.11
SOPDELTA 13C C2-34.24
SOPDELTA 13C C3-29.68
SOPDELTA 13C iC4-31.84
SOPDelta 13C iC5-28.08
SOPDELTA 13C nC4-28.47
SOPDelta 13C nC5-27.7
SOPDELTA D C1-251.1
SOPETHANE8.96MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0356MOL %0.005
SOPHYDROGEN0.181MOL %0.01
SOPISOBUTANE0.342MOL %0.0001
SOPISOPENTANE0.139MOL %0.0001
SOPMETHANE80.85MOL %0.0002
SOPNITROGEN (N2)4.45MOL %0.01
SOPOXYGEN (O2)0.83MOL %0.01
SOPPENTANE0.0925MOL %0.0001
SOPPROPANE3.2MOL %0.0001
SOPPROPENE0.0003MOL %0.0001
SOPSPECIFIC GRAVITY0.673RATIO_AIR