COGIS - Environmental Sample Site Information

 
#437399 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID437399
FacilityTypeOGProj Number
CountyWELD - 123LocationSESW 24 5N63W
Elevation4567Lat/Long40.378677/-104.388802
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-39518Well Name:North Platte O-K-24HC
Well Status:PROperator Name:BONANZA CREEK ENERGY OPERATING COMPANY LLC
Location:SESW  24 5N  63W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   629717     Sample Date:  10/28/2021     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 629717    SPL ID: 21110040-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1314BTU/cuft
SOPBUTANE1.9641MOL %0.001
SOPCARBON DIOXIDE2.2383MOL %0.001
SOPETHENE14.6623MOL %0.001
SOPHEXANES0.5408MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %
SOPISOBUTANE0.8003MOL %0.001
SOPISOPENTANE0.2745MOL %0.001
SOPMETHANE71.5428MOL %0.001
SOPNITROGEN (N2)0.4171MOL %0.001
SOPPENTANE0.3022MOL %0.001
SOPPROPANE7.2575MOL %0.001
SOPSPECIFIC GRAVITY0.7873RATIO_AIR

 Sample ID:   637469     Sample Date:  04/29/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 637469    SPL ID: 22050014-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1381BTU/cuft
SOPBUTANE2.5404MOL %0.001
SOPCARBON DIOXIDE2.0879MOL %0.001
SOPETHENE14.6397MOL %0.001
SOPHEXANES0.5758MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %
SOPISOBUTANE1.097MOL %0.001
SOPISOPENTANE0.5585MOL %0.001
SOPMETHANE68.846MOL %0.001
SOPNITROGEN (N2)0.3612MOL %0.001
SOPPENTANE0.8546MOL %0.001
SOPPROPANE8.4388MOL %0.001
SOPSPECIFIC GRAVITY0.8273RATIO_AIR

 Sample ID:   668205     Sample Date:  04/22/2025     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 668205    SPL ID: 25050060-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1293BTU/cuft
SOPBUTANE1.7823MOL %0.001
SOPCARBON DIOXIDE2.3455MOL %0.001
SOPETHENE14.7965MOL %0.001
SOPHEXANES0.3057MOL %0.001
SOPHYDROGEN SULFIDE0.0003MOL %
SOPISOBUTANE0.6698MOL %0.001
SOPISOPENTANE0.2786MOL %0.001
SOPMETHANE71.8587MOL %0.001
SOPNITROGEN (N2)0.5785MOL %0.001
SOPPENTANE0.3309MOL %0.001
SOPPROPANE7.0532MOL %0.001
SOPSPECIFIC GRAVITY0.7773RATIO_AIR

 Sample ID:   632684     Sample Date:  01/21/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 632684    SPL ID: 22010163-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1307BTU/cuft
SOPBUTANE1.9567MOL %0.001
SOPCARBON DIOXIDE2.1018MOL %0.001
SOPETHENE14.68MOL %0.001
SOPHEXANES0.2866MOL %0.001
SOPHYDROGEN SULFIDE0.0002MOL %
SOPISOBUTANE0.7389MOL %0.001
SOPISOPENTANE0.3204MOL %0.001
SOPMETHANE71.8439MOL %0.001
SOPNITROGEN (N2)0.4276MOL %0.001
SOPPENTANE0.3816MOL %0.001
SOPPROPANE7.2623MOL %0.001
SOPSPECIFIC GRAVITY0.7807RATIO_AIR

 Sample ID:   632687     Sample Date:  01/20/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 632687    SPL ID: 22010163-003A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1298BTU/cuft
SOPBUTANE1.9355MOL %0.001
SOPCARBON DIOXIDE2.175MOL %0.001
SOPETHENE14.3525MOL %0.001
SOPHEXANES0.232MOL %0.001
SOPHYDROGEN SULFIDE0.0002MOL %
SOPISOBUTANE0.7451MOL %0.001
SOPISOPENTANE0.3201MOL %0.001
SOPMETHANE72.3952MOL %0.001
SOPNITROGEN (N2)0.4279MOL %0.001
SOPPENTANE0.3825MOL %0.001
SOPPROPANE7.034MOL %0.001
SOPSPECIFIC GRAVITY0.7759RATIO_AIR