Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#435953 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID435953
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSW 2 5N62W
Elevation4624Lat/Long40.42427/-104.29647
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-38878Well Name:State Antelope D14-X44-2HNC
Well Status:PROperator Name:BONANZA CREEK ENERGY OPERATING COMPANY LLC
Location:SWSW  2  5N  62W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   652457     Sample Date:  09/28/2023     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 652457    SPL ID: 23100056-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1350BTU/cuft
SOPBUTANE2.5436MOL %0.001
SOPCARBON DIOXIDE2.5314MOL %0.001
SOPETHENE13.7119MOL %0.001
SOPHEXANES0.4726MOL %0.001
SOPHYDROGEN SULFIDE0.0003MOL %
SOPISOBUTANE0.8621MOL %0.001
SOPISOPENTANE0.429MOL %0.001
SOPMETHANE69.0749MOL %0.001
SOPNITROGEN (N2)0.7982MOL %0.001
SOPPENTANE0.5101MOL %0.001
SOPPROPANE9.0659MOL %0.001
SOPSPECIFIC GRAVITY0.8195RATIO_AIR

 Sample ID:   627526     Sample Date:  08/19/2021     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  SPL

Sample Results for Sample # 627526    SPL ID: 21080195-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1417BTU/cuft
SOPBUTANE3.5128MOL %0.001
SOPCARBON DIOXIDE2.4319MOL %0.001
SOPETHENE13.4005MOL %0.001
SOPHEXANES0.931MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %0.0001
SOPISOBUTANE1.0571MOL %0.001
SOPISOPENTANE0.7562MOL %0.001
SOPMETHANE67.4743MOL %0.001
SOPNITROGEN (N2)0.6334MOL %0.001
SOPPENTANE0.9904MOL %0.001
SOPPROPANE8.8123MOL %0.001
SOPSPECIFIC GRAVITY0.8593RATIO_AIR

 Sample ID:   627527     Sample Date:  08/19/2021     Matrix:  WATER     Collection Point:  PRDC     Type:  PCS     Lab:  SPL

Sample Results for Sample # 627527    SPL ID: 21080195-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1327BTU/cuft
SOPBUTANE2.4738MOL %0.001
SOPCARBON DIOXIDE2.8209MOL %0.001
SOPETHENE13.3117MOL %0.001
SOPHEXANES0.3989MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %0.0001
SOPISOBUTANE0.7975MOL %0.001
SOPISOPENTANE0.4296MOL %0.001
SOPMETHANE70.476MOL %0.001
SOPNITROGEN (N2)0.588MOL %0.001
SOPPENTANE0.5175MOL %0.001
SOPPROPANE8.186MOL %0.001
SOPSPECIFIC GRAVITY0.807RATIO_AIR

 Sample ID:   637462     Sample Date:  04/19/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 637462    SPL ID: 22040135-003A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1586BTU/cuft
SOPBUTANE3.8004MOL %0.001
SOPCARBON DIOXIDE2.5781MOL %0.001
SOPETHENE21.073MOL %0.001
SOPHEXANES0.8956MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %
SOPISOBUTANE1.4037MOL %0.001
SOPISOPENTANE0.4427MOL %0.001
SOPMETHANE52.6296MOL %0.001
SOPNITROGEN (N2)0.236MOL %0.001
SOPPENTANE0.5315MOL %0.001
SOPPROPANE16.4093MOL %0.001
SOPSPECIFIC GRAVITY0.9651RATIO_AIR

 Sample ID:   637463     Sample Date:  04/15/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 637463    SPL ID: 22040135-005A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1347BTU/cuft
SOPBUTANE2.4858MOL %0.001
SOPCARBON DIOXIDE2.4039MOL %0.001
SOPETHENE13.588MOL %0.001
SOPHEXANES0.4709MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %
SOPISOBUTANE0.8541MOL %0.001
SOPISOPENTANE0.3904MOL %0.001
SOPMETHANE69.7638MOL %0.001
SOPNITROGEN (N2)0.6336MOL %0.001
SOPPENTANE0.4883MOL %0.001
SOPPROPANE8.9211MOL %0.001
SOPSPECIFIC GRAVITY0.8134RATIO_AIR