Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#432230 Information View DocsDoc View GISGIS
Sample Site ID432230
FacilityTypeOGProj Number
CountyWELD - 123LocationNENW 8 2N66W
Elevation4858Lat/Long40.159765/-104.804113
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-37028Well Name:KUNZMAN 4N-5HZ
Well Status:PROperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NENW  8  2N  66W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   629695     Sample Date:  08/18/2021     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 629695    Dolan Integration Group ID: DIG-026005
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1259BTU/cuft
SOPBUTANE1.866MOL %0.005
SOPC6+ (hexanes +)0.098MOL %0.005
SOPCARBON DIOXIDE2.055MOL %0.005
SOPDELTA 13C C1-48.1per mil
SOPDELTA 13C C2-32.3per mil
SOPDELTA 13C C3-29per mil
SOPDELTA 13C CO22.7per mil
SOPDELTA 13C iC4-31per mil
SOPDelta 13C iC5-28.4per mil
SOPDELTA 13C nC4-28.4per mil
SOPDelta 13C nC5-28.1per mil
SOPDELTA D C1-249per mil
SOPETHANE13.45MOL %0.005
SOPETHENE0.007MOL %0.005
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.027MOL %0.005
SOPISOBUTANE0.793MOL %0.005
SOPISOPENTANE0.443MOL %0.005
SOPMETHANE73.341MOL %0.005
SOPNITROGEN (N2)1.223MOL %0.005
SOPOXYGEN + ARGON0.217MOL %0.005
SOPPENTANE0.505MOL %0.005
SOPPROPANE5.973MOL %0.005
SOPSPECIFIC GRAVITY0.762No Unit

 Sample ID:   629694     Sample Date:  08/18/2021     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 629694    Dolan Integration Group ID: DIG-026004
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS5BTU/cuft
SOPBUTANE0.007MOL %0.005
SOPC6+ (hexanes +)NDMOL %0.005ND
SOPCARBON DIOXIDE0.115MOL %0.005
SOPDELTA 13C C1-54.2per mil
SOPDELTA 13C CO2-14.3per mil
SOPDELTA D C1-253per mil
SOPETHANE0.034MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANENDMOL %0.005ND
SOPISOPENTANENDMOL %0.005ND
SOPMETHANE0.227MOL %0.005
SOPNITROGEN (N2)78.117MOL %0.005
SOPOXYGEN + ARGON21.482MOL %0.005
SOPPENTANENDMOL %0.005ND
SOPPROPANE0.018MOL %0.005
SOPSPECIFIC GRAVITY0.997No Unit

 Sample ID:   608678     Sample Date:  06/17/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 608678    ISOTECH ID: 723899
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1267BTU
SOPBUTANE1.7MOL %0.0001
SOPC6+ (hexanes +)0.1MOL %0.0001
SOPCARBON DIOXIDE2.08MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.52
SOPDELTA 13C C2-32.09
SOPDELTA 13C C3-28.83
SOPDELTA 13C CO23.66
SOPDELTA 13C iC4-31.36
SOPDelta 13C iC5-28.21
SOPDELTA 13C nC4-27.92
SOPDelta 13C nC5-27.37
SOPDELTA D C1-244.1
SOPETHANE14.07MOL %0.0001
SOPETHENE0.0002MOL %0.0001
SOPHelium0.0067MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.738MOL %0.0001
SOPISOPENTANE0.343MOL %0.0001
SOPMETHANE74.36MOL %0.0002
SOPNITROGEN (N2)0.36MOL %0.01
SOPOXYGEN (O2)0.017MOL %0.01
SOPPENTANE0.355MOL %0.0001
SOPPROPANE5.87MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.752RATIO_AIR

 Sample ID:   608673     Sample Date:  06/17/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 608673    ISOTECH ID: 723892
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON1.07MOL %0.005
SOPBRITISH THERMAL UNITS538BTU
SOPBUTANE0.519MOL %0.0001
SOPC6+ (hexanes +)0.0238MOL %0.0001
SOPCARBON DIOXIDE1.86MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.8
SOPDELTA 13C C2-32.1
SOPDELTA 13C C3-28.8
SOPDELTA 13C CO2-17.9
SOPDELTA D C1-248.6
SOPETHANE7.74MOL %0.0001
SOPETHENE0.0043MOL %0.0001
SOPHELIUM DILUTION FACTOR0.91NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.23MOL %0.0001
SOPISOPENTANE0.0563MOL %0.0001
SOPMETHANE29.44MOL %0.0002
SOPNITROGEN (N2)54.36MOL %0.01
SOPOXYGEN (O2)1.78MOL %0.01
SOPPENTANE0.0466MOL %0.0001
SOPPROPANE2.87MOL %0.0001
SOPPROPENE0.0043MOL %0.0001
SOPSPECIFIC GRAVITY0.894RATIO_AIR

 Sample ID:   608677     Sample Date:  06/17/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 608677    Accutest ID: DA16768-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   608674     Sample Date:  06/17/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 608674    ISOTECH ID: 723892
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.54mg/L0.03
SOPETHANE3.1mg/L0.0004
SOPMETHANE6mg/L0.0004
SOPNITROGEN (N2)18mg/L0.04
SOPPROPANE1.6mg/L0.0006

 Sample ID:   608676     Sample Date:  06/17/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 608676    Accutest ID: DA16767-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDpH, FIELD11.5SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1510UMHOS/CM0.5
FIELDTEMPERATURE, FIELD26.7degrees C
SW8015TVPH - Gasoline Range Organics3.33mg/L0.25
SW8260BENZENE51.6ug/L25
SW8260ETHYLBENZENE16.4ug/L25J
SW8260M-+P-XYLENE99.8ug/L25
SW8260o-XYLENE38.3ug/L25
SW8260TOLUENE461ug/L25
SW8260TOTAL XYLENES138ug/L25