Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#427029 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID427029
FacilityTypeOGProj Number
CountyWELD - 123LocationNWNE 22 2N66W
Elevation5053Lat/Long40.129807/-104.761289
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-34829Well Name:GOBBLER 36N-E22HZ
Well Status:PROperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWNE  22 2N  66W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   673462     Sample Date:  09/29/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 673462    ISOTECH ID: 985812
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.935MOL %0.005
SOPBRITISH THERMAL UNITS323BTU
SOPBUTANE0.364MOL %0.0001
SOPC6+ (hexanes +)0.117MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDE0.18MOL %0.01
SOPDELTA 13C C1-48.92
SOPDELTA 13C C2-33.58
SOPDELTA 13C C3-29.3
SOPDELTA 13C iC4-31.8
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-28.2
SOPDelta 13C nC5-28.5
SOPDELTA D C1-260.2
SOPETHANE3.57MOL %0.0001
SOPETHENE0.0211MOL %0.0001
SOPHELIUM DILUTION FACTOR0.79NA
SOPHYDROGENNDMOL %0.0025ND
SOPISOBUTANE0.155MOL %0.0001
SOPISOPENTANE0.0683MOL %0.0001
SOPMETHANE18.44MOL %0.0002
SOPNITROGEN (N2)63.85MOL %0.01
SOPOXYGEN (O2)10.47MOL %0.01
SOPPENTANE0.0459MOL %0.0001
SOPPROPANE1.7MOL %0.0001
SOPPROPENE0.0847MOL %0.0001
SOPSPECIFIC GRAVITY0.931RATIO_AIR

 Sample ID:   673466     Sample Date:  09/29/2025     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 673466    ISOTECH ID: 985864
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0065MOL %0.005
SOPBRITISH THERMAL UNITS1356BTU
SOPBUTANE2.91MOL %0.0001
SOPC6+ (hexanes +)0.471MOL %0.0001
SOPCARBON DIOXIDE2.1MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.9
SOPDELTA 13C C2-33.5
SOPDELTA 13C C3-29.9
SOPDELTA 13C CO23.1
SOPDELTA 13C iC4-31.8
SOPDelta 13C iC5-28.8
SOPDELTA 13C nC4-28.7
SOPDelta 13C nC5-28.3
SOPDELTA D C1-257
SOPETHANE13.6MOL %0.0001
SOPETHENE0.001MOL %0.0001
SOPHelium0.0082MOL %0.0025
SOPHYDROGEN0.0292MOL %0.0025
SOPISOBUTANE1.04MOL %0.0001
SOPISOPENTANE0.761MOL %0.0001
SOPMETHANE70.16MOL %0.0002
SOPNITROGEN (N2)0.75MOL %0.01
SOPOXYGEN (O2)0.11MOL %0.01
SOPPENTANE0.916MOL %0.0001
SOPPROPANE7.13MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.814RATIO_AIR

 Sample ID:   673463     Sample Date:  09/29/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 673463    ISOTECH ID: 985812
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.76mg/L0.02
SOPETHANE2.3mg/L0.0003
SOPMETHANE6.1mg/L0.0003
SOPNITROGEN (N2)34mg/L0.03
SOPPROPANE1.6mg/L0.0004

 Sample ID:   673464     Sample Date:  09/29/2025     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 673464    Accutest ID: DA75749-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8BARIUM0.189mg/L0.01
E200.8BORON0.593mg/L0.04
E200.8CALCIUMNDmg/L2U
E200.8IRON0.632mg/L0.1
E200.8MAGNESIUMNDmg/L0.5U
E200.8MANGANESE0.0051mg/L0.005
E200.8POTASSIUM14.2mg/L1
E200.8SELENIUMNDmg/L0.002U
E200.8SODIUM804mg/L50
E200.8STRONTIUMNDmg/L0.1U
E300.0BROMIDE1.5mg/L0.5
E300.0CHLORIDE262mg/L13
E300.0FLUORIDE31.8mg/L2.5
E300.0NITRATE0.15mg/L0.1
E300.0NITRATE/NITRITE AS N0.15mg/L0.14
E300.0NITRITENDmg/L0.04U
E300.0SULFATE62.1mg/L5
FIELDpH, FIELD10.5SU
FIELDSPECIFIC CONDUCTIVITY, FIELD3250umhos/cm0.5
FIELDTEMPERATURE, FIELD27.5degrees C
SM1030CATION - ANION BALANCE19%
SM2320BBICARBONATE ALKALINITY as CACO3390mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3295mg/L5
SM2320BTOTAL ALKALINITY AS CACO3685mg/L5
SM2510BSPECIFIC CONDUCTIVITY3500umhos/cm1
SM2540CTOTAL DISSOLVED SOLIDS2180mg/L10
SM4500-H+ BpH, FIELD10.26SU
SW8015TEPH DIESEL RANGE ORGANICS40.5mg/L1.8
SW8015TVPH - Gasoline Range Organics20.3mg/L2.5
SW8260BENZENE162ug/L50
SW8260ETHYLBENZENE49.6ug/L50J
SW8260M-+P-XYLENE335ug/L50
SW8260o-XYLENE455ug/L50
SW8260TOLUENE389ug/L50
SW8260TOTAL XYLENES790ug/L50

 Sample ID:   673465     Sample Date:  09/29/2025     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 673465    Accutest ID: DA75750-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   637004     Sample Date:  04/12/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 637004    ISOTECH ID: 825729
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1271BTU
SOPBUTANE2.08MOL %0.0001
SOPC6+ (hexanes +)0.0043MOL %0.0001
SOPCARBON DIOXIDE1.88MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.2
SOPDELTA 13C C2-33.2
SOPDELTA 13C C3-29.7
SOPDELTA 13C CO23.6
SOPDELTA 13C iC4-31.7
SOPDelta 13C iC5-28.1
SOPDELTA 13C nC4-28.2
SOPDelta 13C nC5-27.6
SOPDELTA D C1-253
SOPETHANE12.88MOL %0.0001
SOPETHENE0.0011MOL %0.0001
SOPHelium0.011MOL %0.005
SOPHYDROGEN0.0482MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.827MOL %0.0001
SOPISOPENTANE0.411MOL %0.0001
SOPMETHANE74.95MOL %0.0002
SOPNITROGEN (N2)0.46MOL %0.01
SOPOXYGEN (O2)0.014MOL %0.01
SOPPENTANE0.379MOL %0.0001
SOPPROPANE6.05MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.752RATIO_AIR

 Sample ID:   637006     Sample Date:  04/12/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 637006    ISOTECH ID: 826013
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.48mg/L0.02
SOPETHANE3mg/L0.0003
SOPMETHANE7.4mg/L0.0003
SOPNITROGEN (N2)16mg/L0.02
SOPPROPANE1.3mg/L0.0004

 Sample ID:   637005     Sample Date:  04/12/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 637005    ISOTECH ID: 826013
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.995MOL %0.005
SOPBRITISH THERMAL UNITS599BTU
SOPBUTANE0.351MOL %0.0001
SOPC6+ (hexanes +)0.0505MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDE0.13MOL %0.01
SOPDELTA 13C C1-48.55
SOPDELTA 13C C2-33.28
SOPDELTA 13C C3-29.64
SOPDELTA 13C iC4-32.1
SOPDELTA 13C nC4-28.6
SOPDELTA D C1-249
SOPETHANE7.61MOL %0.0001
SOPETHENE0.0098MOL %0.0001
SOPHELIUM DILUTION FACTOR0.87NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.136MOL %0.0001
SOPISOPENTANE0.0354MOL %0.0001
SOPMETHANE37.6MOL %0.0002
SOPNITROGEN (N2)50.07MOL %0.01
SOPOXYGEN (O2)0.56MOL %0.01
SOPPENTANE0.0317MOL %0.0001
SOPPROPANE2.42MOL %0.0001
SOPPROPENE0.0015MOL %0.0001
SOPSPECIFIC GRAVITY0.843RATIO_AIR

 Sample ID:   657886     Sample Date:  01/04/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 657886    ISOTECH ID: 905613
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON1.12MOL %0.005
SOPBRITISH THERMAL UNITS282BTU
SOPBUTANE0.139MOL %0.0001
SOPC6+ (hexanes +)0.0389MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDE0.19MOL %0.01
SOPDELTA 13C C1-48.74
SOPDELTA 13C C2-33.24
SOPDELTA 13C C3-29.59
SOPDELTA 13C iC4-31.9
SOPDELTA 13C nC4-28.5
SOPDELTA D C1-238.7
SOPETHANE3.39MOL %0.0001
SOPETHENE0.0046MOL %0.0001
SOPHELIUM DILUTION FACTOR0.7NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.0534MOL %0.0001
SOPISOPENTANE0.0125MOL %0.0001
SOPMETHANE18.33MOL %0.0002
SOPNITROGEN (N2)75.11MOL %0.01
SOPOXYGEN (O2)0.54MOL %0.01
SOPPENTANE0.0112MOL %0.0001
SOPPROPANE1.06MOL %0.0001
SOPPROPENE0.0007MOL %0.0001
SOPSPECIFIC GRAVITY0.908RATIO_AIR

 Sample ID:   657888     Sample Date:  01/04/2024     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 657888    ISOTECH ID: 906277
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0053MOL %0.005
SOPBRITISH THERMAL UNITS1277BTU
SOPBUTANE1.98MOL %0.0001
SOPC6+ (hexanes +)0.0445MOL %0.0001
SOPCARBON DIOXIDE2.09MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49
SOPDELTA 13C C2-33.7
SOPDELTA 13C C3-29.6
SOPDELTA 13C CO22.5
SOPDELTA 13C iC4-31.7
SOPDelta 13C iC5-28.6
SOPDELTA 13C nC4-28.5
SOPDelta 13C nC5-28.1
SOPDELTA D C1-255
SOPETHANE13.8MOL %0.0001
SOPETHENE0.0004MOL %0.0001
SOPHelium0.0091MOL %0.005
SOPHYDROGEN0.189MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.799MOL %0.0001
SOPISOPENTANE0.377MOL %0.0001
SOPMETHANE73.18MOL %0.0002
SOPNITROGEN (N2)0.61MOL %0.01
SOPOXYGEN (O2)0.06MOL %0.01
SOPPENTANE0.385MOL %0.0001
SOPPROPANE6.47MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.762RATIO_AIR

 Sample ID:   657887     Sample Date:  01/04/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 657887    ISOTECH ID: 905613
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.9mg/L0.01
SOPETHANE2.2mg/L0.0002
SOPMETHANE6mg/L0.0002
SOPNITROGEN (N2)38mg/L0.02
SOPPROPANE0.96mg/L0.0003

 Sample ID:   657884     Sample Date:  01/04/2024     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 657884    Accutest ID: DA61117-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDpH, FIELD12.5SU
FIELDSPECIFIC CONDUCTIVITY, FIELD4860umhos/cm0.5
FIELDTEMPERATURE, FIELD7.4degrees C
SW8260BENZENE45.6ug/L10
SW8260ETHYLBENZENE10.3ug/L10
SW8260M-+P-XYLENE64.5ug/L10
SW8260o-XYLENE67.2ug/L10
SW8260TOLUENE117ug/L10
SW8260TOTAL XYLENES132ug/L10

 Sample ID:   657885     Sample Date:  01/04/2024     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 657885    Accutest ID: DA61118-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U