Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#415233 Information View DocsDoc View GISGIS
Sample Site ID415233
FacilityTypeOGProj Number
CountyWELD - 123LocationNWSW 35 1N67W
Elevation5029Lat/Long40.005905/-104.86526
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-31019Well Name:DRY CREEK 11-35
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWSW  35 1N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   659893     Sample Date:  4/11/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 659893    ISOTECH ID: 918443
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.372MOL %0.005
SOPBRITISH THERMAL UNITS1858BTU
SOPBUTANE12.75MOL %0.0001
SOPC6+ (hexanes +)6.13MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.56
SOPDELTA 13C C2-34.06
SOPDELTA 13C C3-30.18
SOPDELTA 13C iC4-32.04
SOPDelta 13C iC5-28.65
SOPDELTA 13C nC4-28.75
SOPDelta 13C nC5-28.19
SOPDELTA D C1-237.6
SOPETHANE7.29MOL %0.0001
SOPETHENE0.0024MOL %0.0001
SOPHELIUM DILUTION FACTOR0.65NA
SOPHYDROGENNDMOL %0.0025ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE4.19MOL %0.0001
SOPISOPENTANE4.41MOL %0.0001
SOPMETHANE17.92MOL %0.0002
SOPNITROGEN (N2)24.77MOL %0.01
SOPOXYGEN (O2)4.97MOL %0.01
SOPPENTANE4.73MOL %0.0001
SOPPROPANE12.46MOL %0.0001
SOPPROPENE0.0008MOL %0.0001
SOPSPECIFIC GRAVITY1.414RATIO_AIR

 Sample ID:   659894     Sample Date:  4/11/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 659894    ISOTECH ID: 918443
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.43mg/L0.02
SOPETHANE6.8mg/L0.0003
SOPMETHANE8.4mg/L0.0003
SOPNITROGEN (N2)18mg/L0.02
SOPPROPANE16mg/L0.0004

 Sample ID:   659896     Sample Date:  4/11/2024     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 659896    Accutest ID: DA63650-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   659897     Sample Date:  4/11/2024     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 659897    ISOTECH ID: 917884
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1230BTU
SOPBUTANE1.44MOL %0.0001
SOPC6+ (hexanes +)0.0066MOL %0.0001
SOPCARBON DIOXIDE1.55MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.17
SOPDELTA 13C C2-34.43
SOPDELTA 13C C3-30.51
SOPDELTA 13C CO20.81
SOPDELTA 13C iC4-32.15
SOPDelta 13C iC5-28.42
SOPDELTA 13C nC4-28.98
SOPDelta 13C nC5-27.59
SOPDELTA D C1-258.3
SOPETHANE12.48MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0132MOL %0.0025
SOPHYDROGEN0.209MOL %0.0025
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.559MOL %0.0001
SOPISOPENTANE0.202MOL %0.0001
SOPMETHANE76.93MOL %0.0002
SOPNITROGEN (N2)0.67MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.144MOL %0.0001
SOPPROPANE5.79MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.723RATIO_AIR

 Sample ID:   612925     Sample Date:  11/5/2019     Matrix:  Cuttings     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 612925    ISOTECH ID: 740508
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.5mg/L0.02
SOPETHANE5.6mg/L0.0003
SOPMETHANE5.7mg/L0.0003
SOPNITROGEN (N2)29mg/L0.02
SOPPROPANE15mg/L0.0004

 Sample ID:   612924     Sample Date:  11/5/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 612924    ISOTECH ID: 740508
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.415MOL %0.005
SOPBRITISH THERMAL UNITS1588BTU
SOPBUTANE10.69MOL %0.0001
SOPC6+ (hexanes +)5.78MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.6
SOPDELTA 13C C2-33.53
SOPDELTA 13C C3-29.89
SOPDELTA 13C iC4-31.86
SOPDelta 13C iC5-28.54
SOPDELTA 13C nC4-28.53
SOPDelta 13C nC5-27.97
SOPDELTA D C1-258.5
SOPETHANE5.9MOL %0.0001
SOPETHENE0.0022MOL %0.0001
SOPHELIUM DILUTION FACTOR0.69NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE3.81MOL %0.0001
SOPISOPENTANE3.84MOL %0.0001
SOPMETHANE11.77MOL %0.0002
SOPNITROGEN (N2)37.01MOL %0.01
SOPOXYGEN (O2)5.41MOL %0.01
SOPPENTANE3.99MOL %0.0001
SOPPROPANE11.38MOL %0.0001
SOPPROPENE0.001MOL %0.0001
SOPSPECIFIC GRAVITY1.381RATIO_AIR

 Sample ID:   612918     Sample Date:  11/5/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 612918    Accutest ID: DA21705-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.254mg/L0.1
E200.7CALCIUM2.74mg/L0.8
E200.7IRON0.0804mg/L0.02
E200.7MAGNESIUM3.16mg/L0.4
E200.7MANGANESENDmg/L0.01U
E200.7POTASSIUM12mg/L2
E200.7SODIUM265mg/L0.8
E200.7STRONTIUM0.31mg/L0.01
E200.8BARIUM0.0421mg/L0.008
E200.8SELENIUM0.0139mg/L0.0016
E300.0BROMIDE5.6mg/L1.3
E300.0CHLORIDE153mg/L13
E300.0FLUORIDE0.85mg/L0.2
E300.0NITRATE0.034mg/L0.02
E300.0Nitrite as NO20.035mg/L0.008
E300.0SULFATE251mg/L13
FIELDpH, FIELD10.1SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1440UMHOS/CM0.5
FIELDTEMPERATURE, FIELD20.9degrees C
SW8015TVPH - Gasoline Range Organics18.7mg/L1.3
SW8260BENZENE2920ug/L100
SW8260ETHYLBENZENE515ug/L100
SW8260M-+P-XYLENE2410ug/L100
SW8260o-XYLENE1120ug/L100
SW8260TOLUENE403ug/L100
SW8260TOTAL XYLENES3520ug/L100

 Sample ID:   612919     Sample Date:  11/5/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 612919    Accutest ID: DA21706-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   612922     Sample Date:  11/5/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 612922    ISOTECH ID: 740579
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1258BTU
SOPBUTANE1.92MOL %0.0001
SOPC6+ (hexanes +)0.0042MOL %0.0001
SOPCARBON DIOXIDE1.46MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.37
SOPDELTA 13C C2-34.45
SOPDELTA 13C C3-30.48
SOPDELTA 13C CO21.07
SOPDELTA 13C iC4-32.22
SOPDelta 13C iC5-28.29
SOPDELTA 13C nC4-29.08
SOPDelta 13C nC5-27.1
SOPDELTA D C1-273.6
SOPETHANE12.6MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0137MOL %0.005
SOPHYDROGEN0.117MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.692MOL %0.0001
SOPISOPENTANE0.313MOL %0.0001
SOPMETHANE75.75MOL %0.0002
SOPNITROGEN (N2)0.7MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.216MOL %0.0001
SOPPROPANE6.21MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.74RATIO_AIR

 Sample ID:   612923     Sample Date:  11/5/2019     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 612923    Weatherford Laboratories  ID: G9200003
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane516ppm
G02G1,1-dimethylcyclopentane322ppm
G02G1,2,3-trimethylcyclopentane441ppm
G02G1,2,4-trimethylcyclopentane489ppm
G02G2,2,3-trimethylbutane15ppm
G02G2,2-DIMETHYLBUTANE23ppm
G02G2,2-dimethylpentane60ppm
G02G2,3-DIMETHYLBUTANE123ppm
G02G2,3-dimethylpentane39ppm
G02G2,3-dimethylpentane371ppm
G02G2,4-dimethylpentane157ppm
G02G2-METHYLPENTANE833ppm
G02G3-ethylpentane89ppm
G02G3-methylhexane1095ppm
G02G3-methylhexane1247ppm
G02G3-METHYLPENTANE565ppm
G02GBENZENE100ppm
G02GBUTANEppm
G02Gcis-1,3-dimethylcyclopentane501ppm
G02GCYCLOHEXANE1305ppm
G02GCYCLOPENTANE144ppm
G02GDecane11823ppm
G02GETHYLBENZENE784ppm
G02Gethylcyclopentane217ppm
G02GHEPTANES, MIXED ISOMERS3715ppm
G02GHEXANES1635ppm
G02Ghighly branched C25 isoprenoid385ppm
G02GISOBUTANEppm
G02GISOPENTANE619ppm
G02Gisoprenoid C102208ppm
G02Gisoprenoid C112440ppm
G02Gisoprenoid C132751ppm
G02Gisoprenoid C142067ppm
G02Gisoprenoid C152951ppm
G02Gisoprenoid C163841ppm
G02Gisoprenoid C183561ppm
G02Gisoprenoid C91285ppm
G02Gm-XYLENE2697ppm
G02GMETHYL CYCLOHEXANE5357ppm
G02GMETHYLCYCLOPENTANE1145ppm
G02Gn-C1112809ppm
G02Gn-C1211885ppm
G02Gn-C1311910ppm
G02Gn-C1411126ppm
G02Gn-C1510906ppm
G02Gn-C169449ppm
G02Gn-C178754ppm
G02Gn-C187463ppm
G02Gn-C196834ppm
G02Gn-C206391ppm
G02Gn-C215564ppm
G02Gn-C225068ppm
G02Gn-C234574ppm
G02Gn-C244059ppm
G02Gn-C253565ppm
G02Gn-C263194ppm
G02Gn-C272627ppm
G02Gn-C282290ppm
G02Gn-C292179ppm
G02Gn-C301840ppm
G02Gn-C311530ppm
G02Gn-c321174ppm
G02Gn-C331082ppm
G02Gn-C34813ppm
G02Gn-C35625ppm
G02Gn-C36386ppm
G02Gn-C37344ppm
G02Gn-C38233ppm
G02Gn-C39195ppm
G02Gn-C40185ppm
G02Gn-C41103ppm
G02Gn-octane7727ppm
G02GNormal Alkane C910417ppm
G02Go-XYLENE1892ppm
G02Gp-XYLENE1186ppm
G02GPENTANE821ppm
G02GPHENANTHRENE389ppm
G02Gphytane2636ppm
G02Gpristane4696ppm
G02GPropyl-benzene1111ppm
G02GTOLUENE159ppm
G02Gtrans-1,2-dimethylcyclopentane814ppm
G02Gtrans-1,3-dimethylcyclopentane483ppm

 Sample ID:   553706     Sample Date:  8/24/2016     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 553706    ISOTECH ID: 578110
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.459MOL %0.005
SOPBRITISH THERMAL UNITS955BTU
SOPBUTANE4.89MOL %0.0001
SOPC6+ (hexanes +)0.484MOL %0.0001
SOPCARBON DIOXIDE0.033MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.46
SOPDELTA 13C C2-33.38
SOPDELTA 13C C3-29.53
SOPDELTA 13C iC4-31.47
SOPDelta 13C iC5-28.23
SOPDELTA 13C nC4-28.3
SOPDelta 13C nC5-27.82
SOPDELTA D C1-262.1
SOPETHANE10.96MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.0176MOL %0.01
SOPISOBUTANE1.99MOL %0.0001
SOPISOPENTANE0.872MOL %0.0001
SOPMETHANE12.68MOL %0.0002
SOPNITROGEN (N2)43.67MOL %0.01
SOPOXYGEN (O2)10.7MOL %0.01
SOPPENTANE0.814MOL %0.0001
SOPPROPANE12.43MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY1.115RATIO_AIR

 Sample ID:   553708     Sample Date:  8/24/2016     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  ISOTECH

Sample Results for Sample # 553708    ISOTECH ID: 578109
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0091MOL %0.005
SOPBRITISH THERMAL UNITS1323BTU
SOPBUTANE2.05MOL %0.0001
SOPC6+ (hexanes +)0.307MOL %0.0001
SOPCARBON DIOXIDE0.2MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.79
SOPDELTA 13C C2-33.16
SOPDELTA 13C C3-28.69
SOPDELTA 13C iC4-30.73
SOPDelta 13C iC5-28.25
SOPDELTA 13C nC4-28.16
SOPDelta 13C nC5-27.9
SOPDELTA D C1-251.6
SOPETHANE14.8MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0151MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANE0.828MOL %0.0001
SOPISOPENTANE0.598MOL %0.0001
SOPMETHANE73.15MOL %0.0002
SOPNITROGEN (N2)1.09MOL %0.01
SOPOXYGEN (O2)0.1MOL %0.01
SOPPENTANE0.644MOL %0.0001
SOPPROPANE6.21MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.766RATIO_AIR