Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#296490 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID296490
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSW 10 2N68W
Elevation4860Lat/Long40.148206/-104.994275
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-26802Well Name:EVERIST 33-10
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSW  10 2N  68W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   561916     Sample Date:  10/10/2017     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  ISOTECH

Sample Results for Sample # 561916    ISOTECH ID: 633922
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0181MOL %0.005
SOPBRITISH THERMAL UNITS1252BTU
SOPBUTANE1.68MOL %0.0001
SOPC6+ (hexanes +)0.436MOL %0.0001
SOPCARBON DIOXIDE0.95MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.28
SOPDELTA 13C C2-32.57
SOPDELTA 13C C3-28.97
SOPDELTA 13C iC4-31.44
SOPDelta 13C iC5-28.32
SOPDELTA 13C nC4-27.92
SOPDelta 13C nC5-27.61
SOPDELTA D C1-247.4
SOPETHANE12.33MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0145MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANE0.728MOL %0.0001
SOPISOPENTANE0.356MOL %0.0001
SOPMETHANE75.62MOL %0.0002
SOPNITROGEN (N2)1.91MOL %0.01
SOPOXYGEN (O2)0.22MOL %0.01
SOPPENTANE0.351MOL %0.0001
SOPPROPANE5.39MOL %0.0001
SOPPROPENE0.0008MOL %0.0001
SOPSPECIFIC GRAVITY0.744RATIO_AIR

 Sample ID:   561912     Sample Date:  10/10/2017     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 561912    ISOTECH ID: 633923
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0226MOL %0.005
SOPBRITISH THERMAL UNITS1163BTU
SOPBUTANE0.789MOL %0.0001
SOPC6+ (hexanes +)1.06MOL %0.0001
SOPCARBON DIOXIDE0.12MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.03
SOPDELTA 13C C2-32.78
SOPDELTA 13C C3-29.06
SOPDELTA 13C iC4-31.27
SOPDelta 13C iC5-28.58
SOPDELTA 13C nC4-27.74
SOPDelta 13C nC5-27.57
SOPDELTA D C1-243.7
SOPETHANE7.87MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0298MOL %0.005
SOPHYDROGEN0.261MOL %0.01
SOPISOBUTANE0.334MOL %0.0001
SOPISOPENTANE0.254MOL %0.0001
SOPMETHANE83.44MOL %0.0002
SOPNITROGEN (N2)2.53MOL %0.01
SOPOXYGEN (O2)0.41MOL %0.01
SOPPENTANE0.299MOL %0.0001
SOPPROPANE2.58MOL %0.0001
SOPPROPENE0.0025MOL %0.0001
SOPSPECIFIC GRAVITY0.682RATIO_AIR

 Sample ID:   561906     Sample Date:  10/10/2017     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 561906    Accutest ID: D98960-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON5.56mg/L0.05
E200.7CALCIUM18.1mg/L0.4
E200.7IRON0.187mg/L0.01
E200.7MAGNESIUM1.98mg/L0.2
E200.7MANGANESE0.044mg/L0.005
E200.7POTASSIUM9.48mg/L1
E200.7SODIUM1580mg/L8
E200.7STRONTIUM1.11mg/L0.005
E200.8BARIUM0.0601mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE68.6mg/L5
E300.0CHLORIDE2490mg/L250
E300.0FLUORIDE2.1mg/L1
E300.0NITRATE0.97mg/L0.1
E300.0NITRATE/NITRITE AS N0.97mg/L0.5
E300.0Nitrite as NO2NDmg/L0.4U
E300.0SULFATE262mg/L5
E365.1PHOSPHORUS2.8mg/L0.1
FIELDpH, FIELD8.7SU
FIELDSPECIFIC CONDUCTIVITY, FIELD30700UMHOS/CM0.5
FIELDTEMPERATURE, FIELD17.1degrees C
RSK175ETHANE3.3mg/L0.016
RSK175METHANE10.3mg/L0.02
RSK175PROPANE1.3mg/L0.022
SM1030CATION - ANION BALANCE3.9%
SM2320BBICARBONATE ALKALINITY as CACO3NDmg/L5U
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L5U
SM2320BTOTAL ALKALINITY AS CACO3NDmg/L5U
SM2510BSPECIFIC CONDUCTIVITY8910UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS6260mg/L10
SM4500-H+ BpH, FIELD8.48SU
SW8015TEPH DIESEL RANGE ORGANICS30.4mg/L0.95
SW8015TVPH - Gasoline Range Organics41.3mg/L0.5
SW8260BENZENE6210ug/L50
SW8260ETHYLBENZENE230ug/L50
SW8260M-+P-XYLENE2370ug/L50
SW8260o-XYLENE737ug/L50
SW8260TOLUENE6180ug/L50
SW8260TOTAL XYLENES3100ug/L50

 Sample ID:   561908     Sample Date:  10/10/2017     Matrix:  WATER     Collection Point:  BDH     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 561908    Accutest ID: D98961-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   601174     Sample Date:  07/18/2018     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 601174    Dolan Integration Group ID: DIG-015528
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1172BTU/cuft
SOPBUTANE1.02MOL %0.005
SOPC6+ (hexanes +)0.56MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-49.7per mil
SOPDELTA 13C C2-34.3per mil
SOPDELTA 13C C3-29.3per mil
SOPDELTA 13C iC4-30.8per mil
SOPDelta 13C iC5-29.6per mil
SOPDELTA 13C nC4-27.8per mil
SOPDelta 13C nC5-28.1per mil
SOPDELTA D C1-258per mil
SOPETHANE9.77MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.53MOL %0.005
SOPISOPENTANE0.22MOL %0.005
SOPMETHANE80.66MOL %0.005
SOPNITROGEN (N2)2.09MOL %0.005
SOPOXYGEN + ARGON0.32MOL %0.005
SOPPENTANE0.24MOL %0.005
SOPPROPANE4.59MOL %0.005
SOPSPECIFIC GRAVITY0.701RATIO_AIR

 Sample ID:   601175     Sample Date:  07/18/2018     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 601175    Dolan Integration Group ID: DIG-015529
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1205BTU/cuft
SOPBUTANE1.21MOL %0.005
SOPC6+ (hexanes +)0.42MOL %0.005
SOPCARBON DIOXIDE1.57MOL %0.005
SOPDELTA 13C C1-47.6per mil
SOPDELTA 13C C2-32.7per mil
SOPDELTA 13C C3-28.8per mil
SOPDELTA 13C CO23.5per mil
SOPDELTA 13C iC4-31.5per mil
SOPDelta 13C iC5-28.8per mil
SOPDELTA 13C nC4-27.6per mil
SOPDelta 13C nC5-29per mil
SOPDELTA D C1-258per mil
SOPETHANE11.03MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.04MOL %0.005
SOPISOBUTANE0.53MOL %0.005
SOPISOPENTANE0.31MOL %0.005
SOPMETHANE79.08MOL %0.005
SOPNITROGEN (N2)1.04MOL %0.005
SOPOXYGEN + ARGON0.14MOL %0.005
SOPPENTANE0.31MOL %0.005
SOPPROPANE4.32MOL %0.005
SOPSPECIFIC GRAVITY0.693RATIO_AIR

 Sample ID:   601233     Sample Date:  07/18/2018     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 601233    Accutest ID: DA7285-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   601172     Sample Date:  07/18/2018     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 601172    Accutest ID: DA7284-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON5.11mg/L0.5
E200.7CALCIUM15.9mg/L0.4
E200.7IRON0.0456mg/L0.01
E200.7MAGNESIUM4.01mg/L0.2
E200.7MANGANESE0.0118mg/L0.005
E200.7POTASSIUM14.6mg/L1
E200.7SODIUM2160mg/L4
E200.7STRONTIUM1.61mg/L0.005
E200.8BARIUM0.259mg/L0.004
E200.8SELENIUM0.0015mg/L0.0008
E300.0BROMIDE68.8mg/L5
E300.0CHLORIDE2680mg/L250
E300.0FLUORIDE1.2mg/L1
E300.0NITRATENDmg/L0.1U
E300.0NITRATE/NITRITE AS NNDmg/L0.5U
E300.0Nitrite as NO2NDmg/L0.4U
E300.0SULFATE164mg/L5
E365.1PHOSPHORUS0.084mg/L0.01
FIELDpH, FIELD8.6SU
FIELDSPECIFIC CONDUCTIVITY, FIELD9010UMHOS/CM0.5
FIELDTEMPERATURE, FIELD16.7degrees C
RSK175ETHANE2.61mg/L0.016
RSK175METHANE3.96mg/L0.008
RSK175PROPANE3.14mg/L0.022
SM1030CATION - ANION BALANCE1.4%
SM2320BBICARBONATE ALKALINITY as CACO3892mg/L5
SM2320BCARBONATE ALKALINITY AS CACO367.9mg/L5
SM2320BTOTAL ALKALINITY AS CACO3960mg/L5
SM2510BSPECIFIC CONDUCTIVITY12300UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS6660mg/L10
SM4500-H+ BpH, FIELD9.04SU
SW8015TEPH DIESEL RANGE ORGANICS529mg/L5.7
SW8015TVPH - Gasoline Range Organics26.8mg/L0.5
SW8260BENZENE2640ug/L25
SW8260ETHYLBENZENE373ug/L25
SW8260M-+P-XYLENE3220ug/L25
SW8260o-XYLENE1130ug/L25
SW8260TOLUENE4510ug/L25
SW8260TOTAL XYLENES4350ug/L25