Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#295484 Information View DocsDoc View GISGIS
Sample Site ID295484
FacilityTypeOGProj Number
CountyGARFIELD - 045LocationSWSW 27 6S93W
Elevation6474Lat/Long39.49295/-107.76772
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-045-15773Well Name:GMR 27-13A (M27NW)
Well Status:PROperator Name:QB ENERGY OPERATING LLC
Location:SWSW  27 6S  93W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   531698     Sample Date:  04/13/2010     Matrix:  GAS     Collection Point:  BDH     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531698    Questar Applied Technology Services ID: EnCana / M27NW
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0018MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0029MOL %
SOP2,3-DIMETHYLBUTANE0.0046MOL %
SOP2-METHYLPENTANE0.0125MOL %
SOP26# Gasoline GPM0.168015gal/MCF
SOP3-METHYLPENTANE0.0062MOL %
SOPAvg Molecular Weight19.399gm/mole
SOPBase Mol Percent99.719%v/v
SOPBENZENE0.0007MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1000.9BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1017.4BTU
SOPBUTANE0.2959MOL %
SOPButane GPM0.217211gal/MCF
SOPCARBON DIOXIDE1.112MOL %
SOPCYCLOHEXANE0.0034MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0001MOL %
SOPETHANE6.8659MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9976NA
SOPGasoline GPM0.074967gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0166MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.3804MOL %
SOPISOPENTANE0.0893MOL %
SOPM-+P-XYLENE0.0008MOL %
SOPMETHANE79.9739MOL %
SOPMETHYL CYCLOHEXANE0.003MOL %
SOPN-HEXANE0.0121MOL %
SOPNITROGEN (N2)9.0716MOL %
SOPNONANE0.0008MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0.0014MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.0546MOL %
SOPPROPANE2.0974MOL %
SOPPropane GPM0.574819gal/MCF
SOPSample Pressure95PSIG
SOPSample Temperature47degrees F
SOPSPECIFIC GRAVITY0.6713RATIO_AIR
SOPTOLUENE0.0012MOL %
SOPTotal non gas liquids GPM0.866997gal/MCF

 Sample ID:   531700     Sample Date:  04/09/2010     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531700    Questar Applied Technology Services ID: EnCana
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0057MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0057MOL %
SOP2,3-DIMETHYLBUTANE0.0155MOL %
SOP2-METHYLPENTANE0.0453MOL %
SOP26# Gasoline GPM0.396384gal/MCF
SOP3-METHYLPENTANE0.023MOL %
SOPAvg Molecular Weight20.031gm/mole
SOPBase Mol Percent100.154%v/v
SOPBENZENE0.0025MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1037.5BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1054.8BTU
SOPBUTANE0.562MOL %
SOPButane GPM0.367539gal/MCF
SOPCARBON DIOXIDE1.1695MOL %
SOPCYCLOHEXANE0.012MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0032MOL %
SOPETHANE7.3036MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9974NA
SOPGasoline GPM0.219216gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0541MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.5846MOL %
SOPISOPENTANE0.2269MOL %
SOPM-+P-XYLENE0.0011MOL %
SOPMETHANE78.3687MOL %
SOPMETHYL CYCLOHEXANE0.0083MOL %
SOPN-HEXANE0.0481MOL %
SOPNITROGEN (N2)8.8011MOL %
SOPNONANE0.0018MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0.0026MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.1602MOL %
SOPPROPANE2.6184MOL %
SOPPropane GPM0.717606gal/MCF
SOPSample Pressure500PSIG
SOPSample Temperature56degrees F
SOPSPECIFIC GRAVITY0.6932RATIO_AIR
SOPTOLUENE0.0017MOL %
SOPTotal non gas liquids GPM1.30481gal/MCF