Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#283102 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID283102
FacilityTypeOGProj Number
CountyWELD - 123LocationSWNE 1 3N67W
Elevation4780Lat/Long40.25597/-104.83699
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-23614Well Name:BRIGGS 25-1
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWNE  1  3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   622012     Sample Date:  12/03/2020     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 622012    ISOTECH ID: 778618
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0065MOL %0.005
SOPBRITISH THERMAL UNITS1211BTU
SOPBUTANE1.14MOL %0.0001
SOPC6+ (hexanes +)0.224MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.2
SOPDELTA 13C C2-33.2
SOPDELTA 13C C3-28.9
SOPDELTA 13C iC4-31.2
SOPDelta 13C iC5-28.3
SOPDELTA 13C nC4-27.4
SOPDelta 13C nC5-27.1
SOPDELTA D C1-237
SOPETHANE9.69MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0292MOL %0.005
SOPHYDROGEN0.145MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.652MOL %0.0001
SOPISOPENTANE0.308MOL %0.0001
SOPMETHANE81.71MOL %0.0002
SOPNITROGEN (N2)1.14MOL %0.01
SOPOXYGEN (O2)0.091MOL %0.01
SOPPENTANE0.24MOL %0.0001
SOPPROPANE4.62MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.692RATIO_AIR

 Sample ID:   622013     Sample Date:  12/03/2020     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 622013    ISOTECH ID: 778617
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1223BTU
SOPBUTANE1.46MOL %0.0001
SOPC6+ (hexanes +)0.0412MOL %0.0001
SOPCARBON DIOXIDE2.39MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.4
SOPDELTA 13C C2-30.2
SOPDELTA 13C C3-27.1
SOPDELTA 13C CO23.8
SOPDELTA 13C iC4-30.3
SOPDelta 13C iC5-27.5
SOPDELTA 13C nC4-26.3
SOPDelta 13C nC5-26.1
SOPDELTA D C1-231
SOPETHANE12.27MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0076MOL %0.005
SOPHYDROGEN0.0182MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.718MOL %0.0001
SOPISOPENTANE0.318MOL %0.0001
SOPMETHANE77.39MOL %0.0002
SOPNITROGEN (N2)0.3MOL %0.01
SOPOXYGEN (O2)0.032MOL %0.01
SOPPENTANE0.28MOL %0.0001
SOPPROPANE4.78MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.728RATIO_AIR

 Sample ID:   622010     Sample Date:  12/03/2020     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 622010    Accutest ID: DA31003-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.161mg/L0.05
E200.7CALCIUM1.23mg/L0.4
E200.7IRON0.0373mg/L0.01
E200.7MAGNESIUMNDmg/L0.2U
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUM3.87mg/L1
E200.7SODIUM479mg/L0.4
E200.7STRONTIUM0.11mg/L0.005
E200.8BARIUM0.0304mg/L0.004
E200.8SELENIUM0.0013mg/L0.0008
E300.0BROMIDE2.3mg/L0.25
E300.0CHLORIDE476mg/L25
E300.0FLUORIDE1.8mg/L0.5
E300.0NITRATENDmg/L0.05U
E300.0Nitrite as NO2NDmg/L0.2U
E300.0SULFATE2.7mg/L2.5
FIELDpH, FIELD6.1SU
FIELDSPECIFIC CONDUCTIVITY, FIELD2360UMHOS/CM0.5
FIELDTEMPERATURE, FIELD10.4degrees C
RSK175ETHANE3.42mg/L0.08
RSK175METHANE6.94mg/L0.04
RSK175PROPANE2.58mg/L0.11
SM1030CATION - ANION BALANCE2.6%
SM2320BBICARBONATE ALKALINITY as CACO3215mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3210mg/L5
SM2320BTOTAL ALKALINITY AS CACO3425mg/L5
SM2510BSPECIFIC CONDUCTIVITY2050UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS1070mg/L10
SM4500-H+ BpH, FIELD9.81SU
SW8015TEPH DIESEL RANGE ORGANICS2070mg/L220
SW8015TVPH - Gasoline Range Organics632mg/L50
SW8260BENZENE7520ug/L1000
SW8260ETHYLBENZENE1420ug/L1000
SW8260M-+P-XYLENE18100ug/L1000
SW8260o-XYLENE4610ug/L1000
SW8260TOLUENE21900ug/L1000
SW8260TOTAL XYLENES22700ug/L1000

 Sample ID:   622011     Sample Date:  12/03/2020     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 622011    Accutest ID: DA31004-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   636542     Sample Date:  03/30/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 636542    ISOTECH ID: 824048
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1198BTU
SOPBUTANE1.1MOL %0.0001
SOPC6+ (hexanes +)0.342MOL %0.0001
SOPCARBON DIOXIDE2.09MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.14
SOPDELTA 13C C2-30.57
SOPDELTA 13C C3-26.61
SOPDELTA 13C CO22.56
SOPDELTA 13C iC4-29.88
SOPDelta 13C iC5-27.78
SOPDELTA 13C nC4-25.81
SOPDelta 13C nC5-25.76
SOPDELTA D C1-227.1
SOPETHANE10.06MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0125MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.562MOL %0.0001
SOPISOPENTANE0.383MOL %0.0001
SOPMETHANE80.91MOL %0.0002
SOPNITROGEN (N2)0.33MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.339MOL %0.0001
SOPPROPANE3.87MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.708RATIO_AIR

 Sample ID:   636539     Sample Date:  03/30/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 636539    ISOTECH ID: 824049
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1237BTU
SOPBUTANE1.34MOL %0.0001
SOPC6+ (hexanes +)0.297MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.93
SOPDELTA 13C C2-33.13
SOPDELTA 13C C3-28.75
SOPDELTA 13C iC4-31.22
SOPDelta 13C iC5-28.43
SOPDELTA 13C nC4-27.48
SOPDelta 13C nC5-27.1
SOPDELTA D C1-234
SOPETHANE10.04MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0246MOL %0.005
SOPHYDROGEN0.0522MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.713MOL %0.0001
SOPISOPENTANE0.397MOL %0.0001
SOPMETHANE81.24MOL %0.0002
SOPNITROGEN (N2)0.69MOL %0.01
SOPOXYGEN (O2)0.031MOL %0.01
SOPPENTANE0.311MOL %0.0001
SOPPROPANE4.86MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.703RATIO_AIR

 Sample ID:   636541     Sample Date:  03/30/2022     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 636541    Dolan Integration Group ID: DIG-027609
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %6.78%
CALCcarbon preference index (Hunt)1.066Ratio
CALCcarbon preference index (Marzi)1.038Ratio
CALCcycloparaffins %10.059%
CALCisoparaffins % (branched)10.929%
CALCisoprenoids %3.611%
CALCn paraffin %33.52%
CALCnC17/(nC18+nC29) ratio0.898Ratio
CALCnC18/(nC18+nC19) ratio0.547Ratio
CALCphytane/nC18 ratio0.263Ratio
CALCpristane/nC17 ratio0.488Ratio
CALCpristane/phytane ratio2.379Ratio
CALCresolved unknowns %31.282%
G02G1,1,3-Trimethylcyclopentane30.534AREA COUNT1
G02G1,1,3-Trimethylcyclopentane2445ppm10
G02G1,1-dimethylcyclopentane21.099AREA COUNT1
G02G1,1-dimethylcyclopentane1689ppm10
G02G1,2,3-trimethylcyclopentane16.979AREA COUNT1
G02G1,2,3-trimethylcyclopentane1359ppm10
G02G1,2,4-trimethylcyclopentane21.641AREA COUNT1
G02G1,2,4-trimethylcyclopentane1733ppm10
G02G2,2,3-trimethylbutane2.328AREA COUNT1
G02G2,2,3-trimethylbutane183ppm10
G02G2,2-DIMETHYLBUTANE6.03AREA COUNT1
G02G2,2-DIMETHYLBUTANE472ppm10
G02G2,2-dimethylpentane9.673AREA COUNT1
G02G2,2-dimethylpentane759ppm10
G02G2,3-DIMETHYLBUTANE25.015AREA COUNT1
G02G2,3-DIMETHYLBUTANE2003ppm10
G02G2,3-dimethylpentane23.789AREA COUNT1
G02G2,3-dimethylpentane1867ppm10
G02G2,4-dimethylpentane20.775AREA COUNT1
G02G2,4-dimethylpentane1630ppm10
G02G2-methylhexane123.635AREA COUNT1
G02G2-methylhexane9701ppm10
G02G2-METHYLPENTANE137.724AREA COUNT1
G02G2-METHYLPENTANE10773ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane117.293AREA COUNT1
G02G3-methylhexane9203ppm10
G02G3-METHYLPENTANE86.617AREA COUNT1
G02G3-METHYLPENTANE6776ppm10
G02GBENZENE35.225AREA COUNT1
G02GBENZENE2519ppm10
G02GBUTANE68.716AREA COUNT1
G02GBUTANE5309ppm10
G02Gcis-1,3-dimethylcyclopentane28.612AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane2291ppm10
G02GCYCLOHEXANE154.808AREA COUNT1
G02GCYCLOHEXANE12395ppm10
G02GCYCLOPENTANE14.135AREA COUNT1
G02GCYCLOPENTANE1132ppm10
G02GDecane456.065AREA COUNT1
G02GDecane36004ppm10
G02GETHYLBENZENE33.579AREA COUNT1
G02GETHYLBENZENE2611ppm10
G02Gethylcyclopentane14.644AREA COUNT1
G02Gethylcyclopentane1172ppm10
G02GHeptane351.039AREA COUNT1
G02GHeptane27544ppm10
G02GHEXANES252.098AREA COUNT1
G02GHEXANES19720ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANE16.494AREA COUNT1
G02GISOBUTANE1232ppm10
G02GISOPENTANE120.389AREA COUNT1
G02GISOPENTANE9118ppm10
G02Gisoprenoid C1095.27AREA COUNT1
G02Gisoprenoid C107521ppm10
G02Gisoprenoid C1159.75AREA COUNT1
G02Gisoprenoid C114722ppm10
G02Gisoprenoid C1349.512AREA COUNT1
G02Gisoprenoid C133921ppm10
G02Gisoprenoid C1443.794AREA COUNT1
G02Gisoprenoid C143471ppm10
G02Gisoprenoid C1537.624AREA COUNT1
G02Gisoprenoid C152985ppm10
G02Gisoprenoid C1644.55AREA COUNT1
G02Gisoprenoid C163535ppm10
G02Gisoprenoid C1828.799AREA COUNT1
G02Gisoprenoid C182287ppm10
G02Gisoprenoid C935.885AREA COUNT1
G02Gisoprenoid C92827ppm10
G02Gm-XYLENE314.277AREA COUNT1
G02Gm-XYLENE24207ppm10
G02GMETHYL CYCLOHEXANE468.212AREA COUNT1
G02GMETHYL CYCLOHEXANE37488ppm10
G02GMETHYLCYCLOPENTANE118.068AREA COUNT1
G02GMETHYLCYCLOPENTANE9453ppm10
G02Gn-C11368.618AREA COUNT1
G02Gn-C1129130ppm10
G02Gn-C12287.104AREA COUNT1
G02Gn-C1222711ppm10
G02Gn-C13224.191AREA COUNT1
G02Gn-C1317753ppm10
G02Gn-C14165.579AREA COUNT1
G02Gn-C1413125ppm10
G02Gn-C15135.064AREA COUNT1
G02Gn-C1510717ppm10
G02Gn-C1698.453AREA COUNT1
G02Gn-C167812ppm10
G02Gn-C1781.613AREA COUNT1
G02Gn-C176482ppm10
G02Gn-C1863.624AREA COUNT1
G02Gn-C185053ppm10
G02Gn-C1952.589AREA COUNT1
G02Gn-C194177ppm10
G02Gn-C2047.622AREA COUNT1
G02Gn-C203786ppm10
G02Gn-C2137.494AREA COUNT1
G02Gn-C212982ppm10
G02Gn-C2232.574AREA COUNT1
G02Gn-C222591ppm10
G02Gn-C2327.638AREA COUNT1
G02Gn-C232199ppm10
G02Gn-C2423.175AREA COUNT1
G02Gn-C241844ppm10
G02Gn-C2521.776AREA COUNT1
G02Gn-C251734ppm10
G02Gn-C2617.345AREA COUNT1
G02Gn-C261381ppm10
G02Gn-C2714.06AREA COUNT1
G02Gn-C271120ppm10
G02Gn-C2811.728AREA COUNT1
G02Gn-C28934ppm10
G02Gn-C299.254AREA COUNT1
G02Gn-C29737ppm10
G02Gn-C306.308AREA COUNT1
G02Gn-C30503ppm10
G02Gn-C315.076AREA COUNT1
G02Gn-C31405ppm10
G02Gn-c322.965AREA COUNT1
G02Gn-c32236ppm10
G02Gn-C333.166AREA COUNT1
G02Gn-C33252ppm10
G02Gn-C343.281AREA COUNT1
G02Gn-C34262ppm10
G02Gn-C351.752AREA COUNT1
G02Gn-C35140ppm10
G02Gn-C361.166AREA COUNT1
G02Gn-C3690ppm10
G02Gn-C371.163AREA COUNT1
G02Gn-C3789ppm10
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane566.662AREA COUNT1
G02Gn-octane44553ppm10
G02GNormal Alkane C9600.808AREA COUNT1
G02GNormal Alkane C947334ppm10
G02Go-XYLENE101.384AREA COUNT1
G02Go-XYLENE7955ppm10
G02Gp-XYLENE95.955AREA COUNT1
G02Gp-XYLENE7683ppm10
G02GPENTANE154.382AREA COUNT1
G02GPENTANE12015ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane16.758AREA COUNT1
G02Gphytane1332ppm10
G02Gpristane39.859AREA COUNT1
G02Gpristane3166ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE267.849AREA COUNT1
G02GTOLUENE20051ppm10
G02Gtrans-1,2-dimethylcyclopentane49.445AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane3959ppm10
G02Gtrans-1,3-dimethylcyclopentane26.959AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane2158ppm10

 Sample ID:   636538     Sample Date:  03/30/2022     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 636538    Accutest ID: DA43416-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   636543     Sample Date:  03/30/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 636543    Accutest ID: DA43417-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8BARIUM0.0735mg/L0.001
E200.8BORON0.257mg/L0.25
E200.8CALCIUM6.42mg/L0.25
E200.8IRON2.14mg/L0.05
E200.8MAGNESIUM0.787mg/L0.25
E200.8MANGANESE0.035mg/L0.001
E200.8POTASSIUM3.47mg/L0.25
E200.8SELENIUM0.0022mg/L0.001
E200.8SODIUM506mg/L25
E200.8STRONTIUM0.176mg/L0.025
E300.0BROMIDE2.2mg/L0.25
E300.0CHLORIDE533mg/L25
E300.0FLUORIDE1.8mg/L0.5
E300.0NITRATENDmg/L0.05U
E300.0NITRATE/NITRITE AS NNDmg/L0.25U
E300.0NITRITENDmg/L0.2U
E300.0SULFATENDmg/L2.5U
FIELDpH, FIELD10.2SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1840UMHOS/CM0.5
FIELDTEMPERATURE, FIELD11.4degrees C
RSK175ETHANE6.24mg/L0.08
RSK175METHANE11.9mg/L0.04
RSK175PROPANE3.8mg/L0.11
SM1030CATION - ANION BALANCE4.7%
SM2320BBICARBONATE ALKALINITY as CACO3266mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3210mg/L5
SM2320BTOTAL ALKALINITY AS CACO3476mg/L5
SM2510BSPECIFIC CONDUCTIVITY2770UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS1740mg/L10
SM4500-H+ BpH, FIELD9.95SU
SW8015TEPH DIESEL RANGE ORGANICS89.8mg/L0.95
SW8015TVPH - Gasoline Range Organics29.4mg/L0.2
SW8260BENZENE6500ug/L50
SW8260ETHYLBENZENE910ug/L10
SW8260M-+P-XYLENE12300ug/L50
SW8260o-XYLENE3190ug/L50
SW8260TOLUENE9240ug/L100
SW8260TOTAL XYLENES15500ug/L50