Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#265839 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID265839
FacilityTypeOGProj Number
CountyGARFIELD - 045LocationSESE 26 6S93W
Elevation5784Lat/Long39.49109/-107.7371
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-045-09068Well Name:BENZEL 26-16A(P26NWB)
Well Status:PROperator Name:QB ENERGY OPERATING LLC
Location:SESE  26 6S  93W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   531408     Sample Date:  04/12/2010     Matrix:  GAS     Collection Point:  BDH     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531408    Questar Applied Technology Services ID: NA
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.007MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0122MOL %
SOP2,3-DIMETHYLBUTANE0.0028MOL %
SOP2-METHYLPENTANE0.0106MOL %
SOP26# Gasoline GPM0.105023gal/MCF
SOP3-METHYLPENTANE0.0062MOL %
SOPAvg Molecular Weight17.459gm/mole
SOPBase Mol Percent99.513%v/v
SOPBENZENE0.0009MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS988.4BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1004.7BTU
SOPBUTANE0.1261MOL %
SOPButane GPM0.080975gal/MCF
SOPCARBON DIOXIDE0.0023MOL %
SOPCYCLOHEXANE0.0041MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0003MOL %
SOPETHANE2.9254MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9979NA
SOPGasoline GPM0.064892gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0316MOL %
SOPHYDROGEN SULFIDENDMOL %ND
SOPISOBUTANE0.1266MOL %
SOPISOPENTANE0.0462MOL %
SOPM-+P-XYLENE0.0008MOL %
SOPMETHANE90.8839MOL %
SOPMETHYL CYCLOHEXANE0.0087MOL %
SOPN-HEXANE0.0143MOL %
SOPNITROGEN (N2)5.1883MOL %
SOPNONANE0.0026MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0.008MOL %
SOPOXYGEN (O2)NDMOL %ND
SOPPENTANE0.0355MOL %
SOPPROPANE0.5701MOL %
SOPPropane GPM0.156243gal/MCF
SOPSample Pressure100PSIG
SOPSample Temperature48degrees F
SOPSPECIFIC GRAVITY0.6041RATIO_AIR
SOPTOLUENE0.0018MOL %
SOPTotal non gas liquids GPM0.302589gal/MCF

 Sample ID:   531410     Sample Date:  04/09/2010     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531410    Questar Applied Technology Services ID: NA
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0072MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.008MOL %
SOP2,3-DIMETHYLBUTANE0.0223MOL %
SOP2-METHYLPENTANE0.0653MOL %
SOP26# Gasoline GPM0.515003gal/MCF
SOP3-METHYLPENTANE0.0326MOL %
SOPAvg Molecular Weight19.29gm/mole
SOPBase Mol Percent100.19%v/v
SOPBENZENE0.0008MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1163.8BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1183.2BTU
SOPBUTANE0.7186MOL %
SOPButane GPM0.443221gal/MCF
SOPCARBON DIOXIDE0.1019MOL %
SOPCYCLOHEXANE0.0248MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0007MOL %
SOPETHANE8.717MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.997NA
SOPGasoline GPM0.289035gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0653MOL %
SOPHYDROGEN SULFIDENDMOL %ND
SOPISOBUTANE0.6656MOL %
SOPISOPENTANE0.2543MOL %
SOPM-+P-XYLENE0MOL %
SOPMETHANE85.4989MOL %
SOPMETHYL CYCLOHEXANE0.0012MOL %
SOPN-HEXANE0.0893MOL %
SOPNITROGEN (N2)0.3069MOL %
SOPNONANE0MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0MOL %
SOPOXYGEN (O2)NDMOL %ND
SOPPENTANE0.2263MOL %
SOPPROPANE3.2198MOL %
SOPPropane GPM0.882427gal/MCF
SOPSample Pressure500PSIG
SOPSample Temperature52degrees F
SOPSPECIFIC GRAVITY0.6675RATIO_AIR
SOPTOLUENE0.0005MOL %
SOPTotal non gas liquids GPM1.61468gal/MCF