Sample ID: 646887 Sample Date: 12/08/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 646887 ISOTECH ID: 852807 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 1.26 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 168 | BTU | | | | SOP | BUTANE | 0.0259 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0341 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.092 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -61.66 | ‰ | | | | SOP | DELTA 13C C2 | -36.5 | ‰ | | | | SOP | DELTA 13C C3 | -30.9 | ‰ | | | | SOP | DELTA D C1 | -255.4 | ‰ | | | | SOP | ETHANE | 0.253 | MOL % | 0.0001 | | | SOP | ETHENE | 0.003 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.73 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.0141 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0104 | MOL % | 0.0001 | | | SOP | METHANE | 15.51 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 73.62 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 9.06 | MOL % | 0.01 | | | SOP | PENTANE | 0.0074 | MOL % | 0.0001 | | | SOP | PROPANE | 0.105 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0007 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.923 | RATIO_AIR | | |
Sample ID: 646891 Sample Date: 12/08/2022 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 646891 ISOTECH ID: 852812 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0126 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1239 | BTU | | | | SOP | BUTANE | 1.59 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0107 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.51 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.84 | ‰ | | | | SOP | DELTA 13C C2 | -33.13 | ‰ | | | | SOP | DELTA 13C C3 | -29.22 | ‰ | | | | SOP | DELTA 13C CO2 | -3.64 | ‰ | | | | SOP | DELTA 13C iC4 | -31.01 | ‰ | | | | SOP | Delta 13C iC5 | -28.31 | ‰ | | | | SOP | DELTA 13C nC4 | -28 | ‰ | | | | SOP | Delta 13C nC5 | -27.78 | ‰ | | | | SOP | DELTA D C1 | -252.6 | ‰ | | | | SOP | ETHANE | 12.08 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0001 | MOL % | 0.0001 | | | SOP | Helium | 0.0109 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.126 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.666 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.414 | MOL % | 0.0001 | | | SOP | METHANE | 77.26 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 1.7 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.013 | MOL % | 0.01 | | | SOP | PENTANE | 0.424 | MOL % | 0.0001 | | | SOP | PROPANE | 5.18 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.723 | RATIO_AIR | | |
Sample ID: 646890 Sample Date: 12/08/2022 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 646890 Accutest ID: DA51766-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 646888 Sample Date: 12/08/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 646888 ISOTECH ID: 852807 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.79 | mg/L | 0.01 | | | SOP | ETHANE | 0.13 | mg/L | 0.0002 | | | SOP | METHANE | 3.9 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 28 | mg/L | 0.01 | | | SOP | PROPANE | 0.074 | mg/L | 0.0003 | |
Sample ID: 646889 Sample Date: 12/08/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 646889 Accutest ID: DA51765-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.164 | mg/L | 0.004 | | | E200.8 | BORON | 0.434 | mg/L | 0.08 | | | E200.8 | CALCIUM | 9.36 | mg/L | 0.8 | | | E200.8 | IRON | 5.41 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | 2.82 | mg/L | 0.2 | | | E200.8 | MANGANESE | 0.0603 | mg/L | 0.002 | | | E200.8 | POTASSIUM | 4.25 | mg/L | 0.4 | | | E200.8 | SELENIUM | 0.0027 | mg/L | 0.0008 | | | E200.8 | SODIUM | 366 | mg/L | 10 | | | E200.8 | STRONTIUM | 0.575 | mg/L | 0.04 | | | E300.0 | BROMIDE | 6.2 | mg/L | 1.3 | | | E300.0 | CHLORIDE | 251 | mg/L | 13 | | | E300.0 | FLUORIDE | 1.1 | mg/L | 0.2 | | | E300.0 | NITRATE | ND | mg/L | 0.25 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.35 | U | | E300.0 | NITRITE | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | 219 | mg/L | 13 | | | FIELD | pH, FIELD | 9.4 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1470 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 9.44 | degrees C | | | | RSK175 | ETHANE | 0.0717 | mg/L | 0.016 | | | RSK175 | METHANE | 1.6 | mg/L | 0.008 | | | RSK175 | PROPANE | 0.0484 | mg/L | 0.022 | | | SM1030 | CATION - ANION BALANCE | 17.4 | % | | | | SW8015 | TVPH - Gasoline Range Organics | 0.942 | mg/L | 0.05 | | | SW8260 | BENZENE | 46.4 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 9.5 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 60.1 | ug/L | 1 | | | SW8260 | o-XYLENE | 25.2 | ug/L | 1 | | | SW8260 | TOLUENE | 64.9 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 85.4 | ug/L | 1 | |
Sample ID: 612667 Sample Date: 10/22/2019 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 612667 ISOTECH ID: 739015 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.41 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 578 | BTU | | | | SOP | BUTANE | 0.425 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0069 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.094 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -69.54 | ‰ | | | | SOP | DELTA 13C C2 | -35.41 | ‰ | | | | SOP | DELTA 13C C3 | -29.51 | ‰ | | | | SOP | DELTA 13C iC4 | -31.5 | ‰ | | | | SOP | Delta 13C iC5 | -28.53 | ‰ | | | | SOP | DELTA 13C nC4 | -28.47 | ‰ | | | | SOP | Delta 13C nC5 | -27.6 | ‰ | | | | SOP | DELTA D C1 | -272.6 | ‰ | | | | SOP | ETHANE | 0.502 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0004 | MOL % | 0.0001 | | | SOP | Helium | 0.145 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0484 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.138 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.123 | MOL % | 0.0001 | | | SOP | METHANE | 52.17 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 38.15 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 7.18 | MOL % | 0.01 | | | SOP | PENTANE | 0.114 | MOL % | 0.0001 | | | SOP | PROPANE | 0.495 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.775 | RATIO_AIR | | |
Sample ID: 612668 Sample Date: 10/22/2019 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 612668 ISOTECH ID: 739014 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1221 | BTU | | | | SOP | BUTANE | 1.5 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0017 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.18 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.48 | ‰ | | | | SOP | DELTA 13C C2 | -32.61 | ‰ | | | | SOP | DELTA 13C C3 | -29.06 | ‰ | | | | SOP | DELTA 13C CO2 | 2.1 | ‰ | | | | SOP | DELTA 13C iC4 | -31.16 | ‰ | | | | SOP | Delta 13C iC5 | -28.03 | ‰ | | | | SOP | DELTA 13C nC4 | -28.11 | ‰ | | | | SOP | Delta 13C nC5 | -27.28 | ‰ | | | | SOP | DELTA D C1 | -244.6 | ‰ | | | | SOP | ETHANE | 12.23 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0001 | MOL % | 0.0001 | | | SOP | Helium | 0.0144 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0482 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.63 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.25 | MOL % | 0.0001 | | | SOP | METHANE | 77.26 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.52 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.028 | MOL % | 0.01 | | | SOP | PENTANE | 0.209 | MOL % | 0.0001 | | | SOP | PROPANE | 5.13 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.726 | RATIO_AIR | | |
Sample ID: 612665 Sample Date: 10/22/2019 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 612665 Accutest ID: DA21365-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 1.03 | mg/L | 0.05 | | | E200.7 | CALCIUM | 3.72 | mg/L | 0.4 | | | E200.7 | IRON | 0.0807 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | | E200.7 | POTASSIUM | 2.66 | mg/L | 1 | | | E200.7 | SODIUM | 542 | mg/L | 0.4 | | | E200.7 | STRONTIUM | 0.245 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0995 | mg/L | 0.004 | | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | | E300.0 | BROMIDE | 6.4 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 858 | mg/L | 25 | | | E300.0 | FLUORIDE | 2.9 | mg/L | 0.5 | | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | | E300.0 | SULFATE | ND | mg/L | 2.5 | U | | FIELD | pH, FIELD | 10 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 2860 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 14.2 | degrees C | | | | RSK175 | ETHANE | 0.0847 | mg/L | 0.0016 | | | RSK175 | METHANE | 13.2 | mg/L | 0.04 | | | RSK175 | PROPANE | 0.017 | mg/L | 0.0022 | | | SM1030 | CATION - ANION BALANCE | 5.9 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 20.6 | mg/L | 5 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 83.8 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 104 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 2690 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 1490 | mg/L | 10 | | | SM4500-H+ B | pH, FIELD | 9.86 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 2.44 | mg/L | 1.9 | | | SW8015 | TVPH - Gasoline Range Organics | 0.158 | mg/L | 0.05 | | | SW8260 | BENZENE | 7 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 3.1 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 9 | ug/L | 1 | | | SW8260 | o-XYLENE | 7.9 | ug/L | 1 | | | SW8260 | TOLUENE | 3.6 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 16.9 | ug/L | 1 | |
Sample ID: 612666 Sample Date: 10/22/2019 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 612666 Accutest ID: DA21366-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 673867 Sample Date: 10/16/2025 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 673867 ISOTECH ID: 988573 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.53 | mg/L | 0.01 | | | SOP | ETHANE | 0.061 | mg/L | 0.0002 | | | SOP | METHANE | 5.5 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 16 | mg/L | 0.02 | | | SOP | PROPANE | 0.025 | mg/L | 0.0003 | |
Sample ID: 673866 Sample Date: 10/16/2025 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 673866 ISOTECH ID: 988573 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 1.16 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 306 | BTU | | | | SOP | BUTANE | 0.0105 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0078 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -66.42 | ‰ | | | | SOP | DELTA 13C C2 | -39.5 | ‰ | | | | SOP | DELTA D C1 | -267.8 | ‰ | | | | SOP | ETHANE | 0.165 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0024 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.84 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.0025 | ND | | SOP | ISOBUTANE | 0.0067 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0037 | MOL % | 0.0001 | | | SOP | METHANE | 29.65 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 54.9 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 14.05 | MOL % | 0.01 | | | SOP | PENTANE | 0.0019 | MOL % | 0.0001 | | | SOP | PROPANE | 0.0475 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.87 | RATIO_AIR | | |
Sample ID: 673868 Sample Date: 10/16/2025 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 673868 Accutest ID: DA76385-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.044 | mg/L | 0.002 | | | E200.8 | BORON | 0.73 | mg/L | 0.04 | | | E200.8 | CALCIUM | 2.13 | mg/L | 0.4 | | | E200.8 | IRON | 0.0956 | mg/L | 0.02 | | | E200.8 | MAGNESIUM | 0.191 | mg/L | 0.1 | | | E200.8 | MANGANESE | 0.0019 | mg/L | 0.001 | | | E200.8 | POTASSIUM | 1.7 | mg/L | 0.2 | | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | | E200.8 | SODIUM | 337 | mg/L | 10 | | | E200.8 | STRONTIUM | 0.115 | mg/L | 0.02 | | | E300.0 | BROMIDE | 8.5 | mg/L | 0.1 | | | E300.0 | CHLORIDE | 309 | mg/L | 13 | | | E300.0 | FLUORIDE | 1.5 | mg/L | 0.2 | | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | | E300.0 | NITRITE | ND | mg/L | 0.008 | U | | E300.0 | SULFATE | 1510 | mg/L | 13 | | | FIELD | pH, FIELD | 10.5 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1790 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 14.7 | degrees C | | | | SW8260 | BENZENE | 28.6 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 3.2 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 10.4 | ug/L | 1 | | | SW8260 | o-XYLENE | 9.7 | ug/L | 1 | | | SW8260 | TOLUENE | 8.6 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 20.1 | ug/L | 1 | |
Sample ID: 673869 Sample Date: 10/16/2025 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 673869 Accutest ID: DA76385-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | 0.215 | mg/L | 0.1 | |
Sample ID: 673870 Sample Date: 10/16/2025 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 673870 Accutest ID: DA76386-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 673871 Sample Date: 10/16/2025 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 673871 Accutest ID: DA76386-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.1 | U |
Sample ID: 643640 Sample Date: 09/01/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 643640 ISOTECH ID: 841076 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.35 | mg/L | 0.01 | | | SOP | ETHANE | 0.062 | mg/L | 0.0002 | | | SOP | METHANE | 9.3 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 10 | mg/L | 0.01 | | | SOP | PROPANE | 0.017 | mg/L | 0.0003 | |
Sample ID: 643643 Sample Date: 09/01/2022 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 643643 ISOTECH ID: 840916 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1240 | BTU | | | | SOP | BUTANE | 1.6 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0067 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 1.79 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.28 | ‰ | | | | SOP | DELTA 13C C2 | -33.23 | ‰ | | | | SOP | DELTA 13C C3 | -29.39 | ‰ | | | | SOP | DELTA 13C CO2 | 2.19 | ‰ | | | | SOP | DELTA 13C iC4 | -31.13 | ‰ | | | | SOP | Delta 13C iC5 | -28.39 | ‰ | | | | SOP | DELTA 13C nC4 | -28.03 | ‰ | | | | SOP | Delta 13C nC5 | -27.76 | ‰ | | | | SOP | DELTA D C1 | -254.8 | ‰ | | | | SOP | ETHANE | 11.71 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0001 | MOL % | 0.0001 | | | SOP | Helium | 0.0143 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0921 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.681 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.431 | MOL % | 0.0001 | | | SOP | METHANE | 77.4 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.48 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.01 | MOL % | 0.01 | | | SOP | PENTANE | 0.447 | MOL % | 0.0001 | | | SOP | PROPANE | 5.34 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.732 | RATIO_AIR | | |
Sample ID: 643639 Sample Date: 09/01/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 643639 ISOTECH ID: 841076 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.741 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 500 | BTU | | | | SOP | BUTANE | 0.008 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0065 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -67.77 | ‰ | | | | SOP | DELTA 13C C2 | -44 | ‰ | | | | SOP | DELTA D C1 | -269.3 | ‰ | | | | SOP | ETHANE | 0.161 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | HELIUM DILUTION FACTOR | 0.8 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.005 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0025 | MOL % | 0.0001 | | | SOP | METHANE | 48.91 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 35.18 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 14.95 | MOL % | 0.01 | | | SOP | PENTANE | 0.001 | MOL % | 0.0001 | | | SOP | PROPANE | 0.0315 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.789 | RATIO_AIR | | |
Sample ID: 643642 Sample Date: 09/01/2022 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 643642 Accutest ID: DA48735-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 643641 Sample Date: 09/01/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 643641 Accutest ID: DA48734-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.101 | mg/L | 0.004 | | | E200.8 | BORON | 1 | mg/L | 0.08 | | | E200.8 | CALCIUM | 3.9 | mg/L | 0.8 | | | E200.8 | IRON | 0.0755 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.8 | MANGANESE | 0.003 | mg/L | 0.002 | | | E200.8 | POTASSIUM | 2.37 | mg/L | 0.4 | | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | | E200.8 | SODIUM | 583 | mg/L | 10 | | | E200.8 | STRONTIUM | 0.289 | mg/L | 0.04 | | | E300.0 | BROMIDE | 6.4 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 838 | mg/L | 25 | | | E300.0 | FLUORIDE | 2.7 | mg/L | 0.5 | | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.25 | U | | E300.0 | NITRITE | ND | mg/L | 0.2 | U | | E300.0 | SULFATE | ND | mg/L | 2.5 | U | | FIELD | pH, FIELD | 9.7 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 3550 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 29.8 | degrees C | | | | RSK175 | ETHANE | 0.0209 | mg/L | 0.0016 | | | RSK175 | METHANE | 2.45 | mg/L | 0.008 | | | RSK175 | PROPANE | 0.0069 | mg/L | 0.0022 | | | SM1030 | CATION - ANION BALANCE | 0.27 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 15 | mg/L | 5 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 79 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 94 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 2870 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 1310 | mg/L | 10 | | | SM4500-H+ B | pH, FIELD | 9.86 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 1.11 | mg/L | 0.19 | | | SW8015 | TVPH - Gasoline Range Organics | 0.0762 | mg/L | 0.05 | | | SW8260 | BENZENE | 3.4 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 1.6 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 3.8 | ug/L | 1 | | | SW8260 | o-XYLENE | 3.9 | ug/L | 1 | | | SW8260 | TOLUENE | 1.5 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 7.7 | ug/L | 1 | |
Sample ID: 636361 Sample Date: 03/15/2022 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 636361 ISOTECH ID: 821857 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1206 | BTU | | | | SOP | BUTANE | 1.2 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0044 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 1.94 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -50.7 | ‰ | | | | SOP | DELTA 13C C2 | -33.3 | ‰ | | | | SOP | DELTA 13C C3 | -29.3 | ‰ | | | | SOP | DELTA 13C CO2 | 3.4 | ‰ | | | | SOP | DELTA 13C iC4 | -31 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -28.1 | ‰ | | | | SOP | Delta 13C nC5 | -27.9 | ‰ | | | | SOP | DELTA D C1 | -250 | ‰ | | | | SOP | ETHANE | 11.81 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0001 | MOL % | 0.0001 | | | SOP | Helium | 0.014 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.103 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.551 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.256 | MOL % | 0.0001 | | | SOP | METHANE | 78.71 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.48 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.011 | MOL % | 0.01 | | | SOP | PENTANE | 0.242 | MOL % | 0.0001 | | | SOP | PROPANE | 4.68 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.712 | RATIO_AIR | | |
Sample ID: 636362 Sample Date: 03/15/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 636362 ISOTECH ID: 821841 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.332 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 769 | BTU | | | | SOP | BUTANE | 0.0119 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0208 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -68.99 | ‰ | | | | SOP | DELTA 13C C2 | -45.9 | ‰ | | | | SOP | DELTA D C1 | -270.1 | ‰ | | | | SOP | ETHANE | 0.218 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0003 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.61 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.0071 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0079 | MOL % | 0.0001 | | | SOP | METHANE | 75.17 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 19.79 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 4.4 | MOL % | 0.01 | | | SOP | PENTANE | 0.0071 | MOL % | 0.0001 | | | SOP | PROPANE | 0.0332 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0003 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.665 | RATIO_AIR | | |
Sample ID: 636363 Sample Date: 03/15/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 636363 ISOTECH ID: 821841 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.33 | mg/L | 0.01 | | | SOP | ETHANE | 0.18 | mg/L | 0.0002 | | | SOP | METHANE | 30 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 12 | mg/L | 0.02 | | | SOP | PROPANE | 0.037 | mg/L | 0.0003 | |
Sample ID: 636365 Sample Date: 03/15/2022 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 636365 Accutest ID: DA42923-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 636364 Sample Date: 03/15/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 636364 Accutest ID: DA42922-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.093 | mg/L | 0.004 | | | E200.8 | BORON | 0.825 | mg/L | 0.08 | | | E200.8 | CALCIUM | ND | mg/L | 8 | U | | E200.8 | IRON | 0.0549 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 2 | U | | E200.8 | MANGANESE | 0.0027 | mg/L | 0.002 | | | E200.8 | POTASSIUM | ND | mg/L | 4 | U | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | | E200.8 | SODIUM | 519 | mg/L | 13 | | | E200.8 | STRONTIUM | 0.268 | mg/L | 0.04 | | | E300.0 | BROMIDE | 5.8 | mg/L | 1.3 | | | E300.0 | CHLORIDE | 750 | mg/L | 50 | | | E300.0 | FLUORIDE | 2.6 | mg/L | 0.2 | | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.12 | U | | E300.0 | NITRITE | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | ND | mg/L | 1 | U | | FIELD | pH, FIELD | 10.6 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 2790 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 9.5 | degrees C | | | | RSK175 | ETHANE | 0.0826 | mg/L | 0.008 | | | RSK175 | METHANE | 12.6 | mg/L | 0.04 | | | RSK175 | PROPANE | 0.0171 | mg/L | 0.011 | | | SM1030 | CATION - ANION BALANCE | 0.53 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 18.8 | mg/L | 5 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 65 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 83.8 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 2520 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 1390 | mg/L | 10 | | | SM4500-H+ B | pH, FIELD | 9.92 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 5.07 | mg/L | 0.095 | | | SW8015 | TVPH - Gasoline Range Organics | 0.862 | mg/L | 0.05 | | | SW8260 | BENZENE | 14.3 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 8.8 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 89.6 | ug/L | 1 | | | SW8260 | o-XYLENE | 22.7 | ug/L | 1 | | | SW8260 | TOLUENE | 51 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 112 | ug/L | 1 | |
|
|