Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#259412 Information View DocsDoc View GISGIS
Sample Site ID259412
FacilityTypeOGProj Number
CountyWELD - 123LocationNWSW 36 3N67W
Elevation4817Lat/Long40.17997/-104.84643
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-20313Well Name:HSR-VANCE 12-36A
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWSW  36 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   563503     Sample Date:  12/5/2017     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 563503    Accutest ID: DA679-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDpH, FIELD10.6SU
FIELDSPECIFIC CONDUCTIVITY, FIELD2350UMHOS/CM0.5
FIELDTEMPERATURE, FIELD8degrees C
SW8015TVPH - Gasoline Range Organics1.78mg/L0.05
SW8260BENZENE66.9ug/L1
SW8260ETHYLBENZENE22.1ug/L1
SW8260M-+P-XYLENE97.4ug/L1
SW8260o-XYLENE62ug/L1
SW8260TOLUENE54.8ug/L1
SW8260TOTAL XYLENES159ug/L1

 Sample ID:   563505     Sample Date:  12/5/2017     Matrix:  WATER     Collection Point:  TB     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 563505    Accutest ID: DA680-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   563507     Sample Date:  12/5/2017     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  ISOTECH

Sample Results for Sample # 563507    ISOTECH ID: 641835
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0058MOL %0.005
SOPBRITISH THERMAL UNITS1249BTU
SOPBUTANE1.76MOL %0.0001
SOPC6+ (hexanes +)0.008MOL %0.0001
SOPCARBON DIOXIDE0.66MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.31
SOPDELTA 13C C2-32.34
SOPDELTA 13C C3-28.87
SOPDELTA 13C iC4-31.32
SOPDelta 13C iC5-27.92
SOPDELTA 13C nC4-27.98
SOPDelta 13C nC5-26.82
SOPDELTA D C1-250.7
SOPETHANE13.45MOL %0.0001
SOPETHENE0.0002MOL %0.0001
SOPHelium0.0091MOL %0.005
SOPHYDROGEN0.123MOL %0.01
SOPISOBUTANE0.764MOL %0.0001
SOPISOPENTANE0.188MOL %0.0001
SOPMETHANE77.15MOL %0.0002
SOPNITROGEN (N2)0.57MOL %0.01
SOPOXYGEN (O2)0.027MOL %0.01
SOPPENTANE0.125MOL %0.0001
SOPPROPANE5.16MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.72RATIO_AIR