Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#256113 Information View DocsDoc View GISGIS
Sample Site ID256113
FacilityTypeOGProj Number
CountyGARFIELD - 045LocationSWSE 17 6S91 W
ElevationLat/Long39.52183/-107.57603
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-045-07435Well Name:JOLLEY 17-15
Well Status:PROperator Name:TEP ROCKY MOUNTAIN LLC
Location:SWSE  17 6S  91W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   667656     Sample Date:  04/22/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  TEP Rocky Mountain

Sample Results for Sample # 667656    TEP Rocky Mountain ID: BDH-04507435-20250422
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1150.73BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1170.67BTU/cuft dry
GPA 2261-13BUTANE0.6347MOL %
GPA 2261-13C6+ (hexanes +)0.1399MOL %
GPA 2261-13CARBON DIOXIDE0.0302MOL %
GPA 2261-13ETHANE8.7853MOL %
GPA 2261-13ISOBUTANE0.6773MOL %
GPA 2261-13ISOPENTANE0.2245MOL %
GPA 2261-13METHANE84.9287MOL %
GPA 2261-13NITROGEN (N2)1.2407MOL %
GPA 2261-13PENTANE0.1702MOL %
GPA 2261-13PROPANE2.9796MOL %
GPA 2261-13SPECIFIC GRAVITY0.6685Ratio

 Sample ID:   667657     Sample Date:  04/22/2025     Matrix:  GAS     Collection Point:  WellHead     Type:  PRDG     Lab:  TEP Rocky Mountain

Sample Results for Sample # 667657    TEP Rocky Mountain ID: PRDG-04507435-20250422
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1170.56BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1190.83BTU/cuft dry
GPA 2261-13BUTANE0.8002MOL %
GPA 2261-13C6+ (hexanes +)0.1563MOL %
GPA 2261-13CARBON DIOXIDE1.7299MOL %
GPA 2261-13ETHANE9.7155MOL %
GPA 2261-13ISOBUTANE0.8124MOL %
GPA 2261-13ISOPENTANE0.2574MOL %
GPA 2261-13METHANE82.3714MOL %
GPA 2261-13NITROGEN (N2)0.1668MOL %
GPA 2261-13PENTANE0.1904MOL %
GPA 2261-13PROPANE3.5935MOL %
GPA 2261-13SPECIFIC GRAVITY0.6974Ratio

 Sample ID:   456624     Sample Date:  04/22/1999     Matrix:  WATER     Collection Point:       Type:  PIT     Lab:  Grand Junction Laboratories

Sample Results for Sample # 456624    Grand Junction Laboratories
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
UnSpecBARIUM0.9mg/L
UnSpecCALCIUM459mg/L
UnSpecCHLORIDE10300mg/L
UnSpecIRON61.8mg/L
UnSpecMAGNESIUM56mg/L
UnSpecPH, LAB7.4SU
UnSpecRESISTIVITY0.342ohm/M
UnSpecSODIUM5940mg/L
UnSpecSULFATENDmg/LU
UnSpecTOTAL DISSOLVED SOLIDS19500mg/L