Sample Site ID243580
FacilityTypeOGProj Number
CountyWELD - 123LocationNENE 25 2N66W
Elevation5012Lat/Long40.11352/-104.71934
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-11372Well Name:BADDING USX W 25-1
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NENE  25 2N  66W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   566807     Sample Date:  04/04/2018     Matrix:  GAS     Collection Point:  BDH     Type:  PRDG     Lab:  ISOTECH

Sample Results for Sample # 566807    ISOTECH ID: 659699
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1289BTU
SOPBUTANE2.03MOL %0.0001
SOPC6+ (hexanes +)0.0018MOL %0.0001
SOPCARBON DIOXIDE1.78MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.35
SOPDELTA 13C C2-33.06
SOPDELTA 13C C3-29.44
SOPDELTA 13C CO23.09
SOPDELTA 13C iC4-31.64
SOPDelta 13C iC5-28.13
SOPDELTA 13C nC4-28.32
SOPDelta 13C nC5-26.66
SOPDELTA D C1-253.8
SOPETHANE14.54MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0089MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANE0.78MOL %0.0001
SOPISOPENTANE0.588MOL %0.0001
SOPMETHANE73.33MOL %0.0002
SOPNITROGEN (N2)0.46MOL %0.01
SOPOXYGEN (O2)0.02MOL %0.01
SOPPENTANE0.419MOL %0.0001
SOPPROPANE6.04MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.762RATIO_AIR

 Sample ID:   566809     Sample Date:  04/04/2018     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 566809    ISOTECH ID: 659700
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0059MOL %0.005
SOPBRITISH THERMAL UNITS1361BTU
SOPBUTANE2.34MOL %0.0001
SOPC6+ (hexanes +)0.434MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.84
SOPDELTA 13C C2-33.58
SOPDELTA 13C C3-29.66
SOPDELTA 13C iC4-31.55
SOPDelta 13C iC5-28.27
SOPDELTA 13C nC4-28.33
SOPDelta 13C nC5-27.86
SOPDELTA D C1-252.7
SOPETHANE14.13MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0271MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANE1.02MOL %0.0001
SOPISOPENTANE0.434MOL %0.0001
SOPMETHANE71.91MOL %0.0002
SOPNITROGEN (N2)0.85MOL %0.01
SOPOXYGEN (O2)0.034MOL %0.01
SOPPENTANE0.478MOL %0.0001
SOPPROPANE8.34MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.784RATIO_AIR

 Sample ID:   566610     Sample Date:  04/04/2018     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 566610    Weatherford Laboratories  ID: 6126819033
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane1569ppm
G02G1,1-dimethylcyclopentane1355ppm
G02G1,2,3-trimethylcyclopentane1229ppm
G02G1,2,4-trimethylcyclopentane1524ppm
G02G2,2,3-trimethylbutane35ppm
G02G2,2-DIMETHYLBUTANE93ppm
G02G2,2-dimethylpentane214ppm
G02G2,3-DIMETHYLBUTANE543ppm
G02G2,3-dimethylpentane146ppm
G02G2,3-dimethylpentane1667ppm
G02G2,4-dimethylpentane758ppm
G02G2-METHYLPENTANE5409ppm
G02G3-ethylpentane295ppm
G02G3-methylhexane4801ppm
G02G3-methylhexane5331ppm
G02G3-METHYLPENTANE3240ppm
G02GBENZENE2166ppm
G02GBUTANE5446ppm
G02Gcis-1,3-dimethylcyclopentane2022ppm
G02GCYCLOHEXANE6769ppm
G02GCYCLOPENTANE1056ppm
G02GDecane12927ppm
G02GETHYLBENZENE1971ppm
G02Gethylcyclopentane644ppm
G02GHEPTANES, MIXED ISOMERS16524ppm
G02GHEXANES12094ppm
G02Ghighly branched C25 isoprenoid323ppm
G02GISOBUTANE1327ppm
G02GISOPENTANE4840ppm
G02Gisoprenoid C103113ppm
G02Gisoprenoid C113260ppm
G02Gisoprenoid C132764ppm
G02Gisoprenoid C142053ppm
G02Gisoprenoid C152629ppm
G02Gisoprenoid C163252ppm
G02Gisoprenoid C182960ppm
G02Gisoprenoid C92705ppm
G02Gm-XYLENE8694ppm
G02GMETHYL CYCLOHEXANE17521ppm
G02GMETHYLCYCLOPENTANE6001ppm
G02Gn-C1112062ppm
G02Gn-C1210171ppm
G02Gn-C139497ppm
G02Gn-C148516ppm
G02Gn-C157720ppm
G02Gn-C166791ppm
G02Gn-C175999ppm
G02Gn-C185062ppm
G02Gn-C194445ppm
G02Gn-C204348ppm
G02Gn-C213463ppm
G02Gn-C223186ppm
G02Gn-C232754ppm
G02Gn-C242510ppm
G02Gn-C252041ppm
G02Gn-C261839ppm
G02Gn-C271290ppm
G02Gn-C281054ppm
G02Gn-C29881ppm
G02Gn-C30663ppm
G02Gn-C31498ppm
G02Gn-c32369ppm
G02Gn-C33352ppm
G02Gn-C34320ppm
G02Gn-C35224ppm
G02Gn-C36135ppm
G02Gn-C37119ppm
G02Gn-C3889ppm
G02Gn-C3952ppm
G02Gn-C4062ppm
G02Gn-C4133ppm
G02Gn-octane17778ppm
G02GNormal Alkane C914863ppm
G02Go-XYLENE4560ppm
G02Gp-XYLENE2934ppm
G02GPENTANE8498ppm
G02GPHENANTHRENE181ppm
G02Gphytane2113ppm
G02Gpristane3568ppm
G02GPropyl-benzene1511ppm
G02GTOLUENE10632ppm
G02Gtrans-1,2-dimethylcyclopentane3068ppm
G02Gtrans-1,3-dimethylcyclopentane1909ppm