Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#240293 Information View DocsDoc View GISGIS
Sample Site ID240293
FacilityTypeOGProj Number
CountyWELD - 123LocationSESW 25 3N67W
Elevation4806Lat/Long40.191852/-104.843672
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-08081Well Name:CASTOR HANSON UNIT 1
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SESW  25 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   563571     Sample Date:  12/05/2017     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 563571    ISOTECH ID: 641830
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0503MOL %0.005
SOPBRITISH THERMAL UNITS1225BTU
SOPBUTANE1.93MOL %0.0001
SOPC6+ (hexanes +)0.657MOL %0.0001
SOPCARBON DIOXIDE0.016MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-50.04
SOPDELTA 13C C2-33.37
SOPDELTA 13C C3-29.03
SOPDELTA 13C iC4-31.37
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-27.75
SOPDelta 13C nC5-27.1
SOPDELTA D C1-248.3
SOPETHANE9.9MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0352MOL %0.005
SOPHYDROGEN0.225MOL %0.01
SOPISOBUTANE0.85MOL %0.0001
SOPISOPENTANE0.635MOL %0.0001
SOPMETHANE73.6MOL %0.0002
SOPNITROGEN (N2)5.43MOL %0.01
SOPOXYGEN (O2)0.99MOL %0.01
SOPPENTANE0.572MOL %0.0001
SOPPROPANE5.11MOL %0.0001
SOPPROPENE0.002MOL %0.0001
SOPSPECIFIC GRAVITY0.758RATIO_AIR

 Sample ID:   563573     Sample Date:  12/05/2017     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  ISOTECH

Sample Results for Sample # 563573    ISOTECH ID: 641829
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1247BTU
SOPBUTANE1.47MOL %0.0001
SOPC6+ (hexanes +)0.18MOL %0.0001
SOPCARBON DIOXIDE1.53MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.47
SOPDELTA 13C C2-31.72
SOPDELTA 13C C3-28.51
SOPDELTA 13C iC4-31.23
SOPDelta 13C iC5-28.3
SOPDELTA 13C nC4-27.74
SOPDelta 13C nC5-27.3
SOPDELTA D C1-244.4
SOPETHANE13.97MOL %0.0001
SOPETHENE0.0002MOL %0.0001
SOPHelium0.01MOL %0.005
SOPHYDROGEN0.0301MOL %0.01
SOPISOBUTANE0.616MOL %0.0001
SOPISOPENTANE0.323MOL %0.0001
SOPMETHANE76.37MOL %0.0002
SOPNITROGEN (N2)0.4MOL %0.01
SOPOXYGEN (O2)0.025MOL %0.01
SOPPENTANE0.322MOL %0.0001
SOPPROPANE4.75MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.731RATIO_AIR

 Sample ID:   563569     Sample Date:  12/05/2017     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 563569    Weatherford Laboratories  ID: 6126736156
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane1821ppm
G02G1,1-dimethylcyclopentane1618ppm
G02G1,2,3-trimethylcyclopentane1001ppm
G02G1,2,4-trimethylcyclopentane1289ppm
G02G2,2,3-trimethylbutane168ppm
G02G2,2-DIMETHYLBUTANE342ppm
G02G2,2-dimethylpentane769ppm
G02G2,3-DIMETHYLBUTANE1519ppm
G02G2,3-dimethylpentane358ppm
G02G2,3-dimethylpentane1935ppm
G02G2,4-dimethylpentane1483ppm
G02G2-METHYLPENTANE8935ppm
G02G3-ethylpentane459ppm
G02G3-methylhexane7831ppm
G02G3-methylhexane8092ppm
G02G3-METHYLPENTANE5689ppm
G02GBENZENE2293ppm
G02GBUTANE5547ppm
G02Gcis-1,3-dimethylcyclopentane2093ppm
G02GCYCLOHEXANE11823ppm
G02GCYCLOPENTANE1155ppm
G02GDecane18594ppm
G02GETHYLBENZENE1610ppm
G02Gethylcyclopentane811ppm
G02GHEPTANES, MIXED ISOMERS20537ppm
G02GHEXANES16572ppm
G02Ghighly branched C25 isoprenoid233ppm
G02GISOBUTANE1323ppm
G02GISOPENTANE8206ppm
G02Gisoprenoid C103068ppm
G02Gisoprenoid C112706ppm
G02Gisoprenoid C132937ppm
G02Gisoprenoid C142495ppm
G02Gisoprenoid C153040ppm
G02Gisoprenoid C164190ppm
G02Gisoprenoid C183157ppm
G02Gisoprenoid C91548ppm
G02Gm-XYLENE12292ppm
G02GMETHYL CYCLOHEXANE28650ppm
G02GMETHYLCYCLOPENTANE8356ppm
G02Gn-C1118162ppm
G02Gn-C1216220ppm
G02Gn-C1315086ppm
G02Gn-C1413395ppm
G02Gn-C1512070ppm
G02Gn-C1610000ppm
G02Gn-C178704ppm
G02Gn-C187293ppm
G02Gn-C196461ppm
G02Gn-C205889ppm
G02Gn-C215039ppm
G02Gn-C224571ppm
G02Gn-C234021ppm
G02Gn-C243508ppm
G02Gn-C253007ppm
G02Gn-C262446ppm
G02Gn-C271891ppm
G02Gn-C281413ppm
G02Gn-C291168ppm
G02Gn-C30806ppm
G02Gn-C31646ppm
G02Gn-c32436ppm
G02Gn-C33477ppm
G02Gn-C34381ppm
G02Gn-C35273ppm
G02Gn-C36314ppm
G02Gn-C37143ppm
G02Gn-C38127ppm
G02Gn-C3959ppm
G02Gn-C4050ppm
G02Gn-C410ppm
G02Gn-octane21744ppm
G02GNormal Alkane C919835ppm
G02Go-XYLENE4879ppm
G02Gp-XYLENE3658ppm
G02GPENTANE11168ppm
G02GPHENANTHRENE245ppm
G02Gphytane1933ppm
G02Gpristane4148ppm
G02GPropyl-benzene1375ppm
G02GTOLUENE12622ppm
G02Gtrans-1,2-dimethylcyclopentane3047ppm
G02Gtrans-1,3-dimethylcyclopentane1957ppm