Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#429713 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID429713
FacilityTypeGasProj Number
CountyWELD - 123LocationSWSE 10 2N65W
Elevation4869Lat/Long40.147465/-104.649263
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-35875Well Name:COOK 37N-W3HZ
Well Status:PROperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSE  10 2N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   670312     Sample Date:  06/05/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 670312    ISOTECH ID: 971218
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.42MOL %0.005
SOPBRITISH THERMAL UNITS1108BTU
SOPBUTANE2.8MOL %0.0001
SOPC6+ (hexanes +)0.961MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.35
SOPDELTA 13C C2-33.15
SOPDELTA 13C C3-29.63
SOPDELTA 13C iC4-32.52
SOPDelta 13C iC5-28.6
SOPDELTA 13C nC4-28.8
SOPDelta 13C nC5-28.04
SOPDELTA D C1-221.1
SOPETHANE12.52MOL %0.0001
SOPETHENE0.0009MOL %0.0001
SOPHELIUM DILUTION FACTOR0.8NA
SOPHYDROGENNDMOL %0.0025ND
SOPISOBUTANE0.746MOL %0.0001
SOPISOPENTANE0.676MOL %0.0001
SOPMETHANE50.62MOL %0.0002
SOPNITROGEN (N2)23.41MOL %0.01
SOPOXYGEN (O2)1.14MOL %0.01
SOPPENTANE0.789MOL %0.0001
SOPPROPANE5.93MOL %0.0001
SOPPROPENE0.0005MOL %0.0001
SOPSPECIFIC GRAVITY0.882RATIO_AIR

 Sample ID:   670313     Sample Date:  06/05/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 670313    ISOTECH ID: 971218
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.26mg/L0.02
SOPETHANE6.2mg/L0.0002
SOPMETHANE13mg/L0.0002
SOPNITROGEN (N2)9.1mg/L0.02
SOPPROPANE4.1mg/L0.0003

 Sample ID:   670316     Sample Date:  06/05/2025     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 670316    ISOTECH ID: 971547
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0064MOL %0.005
SOPBRITISH THERMAL UNITS1300BTU
SOPBUTANE2.2MOL %0.0001
SOPC6+ (hexanes +)0.381MOL %0.0001
SOPCARBON DIOXIDE2.25MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.7
SOPDELTA 13C C2-33
SOPDELTA 13C C3-29.7
SOPDELTA 13C CO22.6
SOPDELTA 13C iC4-31.3
SOPDelta 13C iC5-28
SOPDELTA 13C nC4-28.3
SOPDelta 13C nC5-27.7
SOPDELTA D C1-249
SOPETHANE13.45MOL %0.0001
SOPETHENE0.0016MOL %0.0001
SOPHelium0.0065MOL %0.0025
SOPHYDROGEN0.0689MOL %0.0025
SOPISOBUTANE0.867MOL %0.0001
SOPISOPENTANE0.512MOL %0.0001
SOPMETHANE72.46MOL %0.0002
SOPNITROGEN (N2)0.73MOL %0.01
SOPOXYGEN (O2)0.12MOL %0.01
SOPPENTANE0.608MOL %0.0001
SOPPROPANE6.34MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.781RATIO_AIR

 Sample ID:   670315     Sample Date:  06/05/2025     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 670315    Accutest ID: DA72857-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   670314     Sample Date:  06/05/2025     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 670314    Accutest ID: DA72858-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8BARIUM0.037mg/L0.01
E200.8BORON0.387mg/L0.2
E200.8CALCIUM12.5mg/L8
E200.8IRON0.985mg/L0.4
E200.8MAGNESIUMNDmg/L0.5U
E200.8MANGANESENDmg/L0.005U
E200.8POTASSIUM394mg/L10
E200.8SELENIUM0.0183mg/L0.008
E200.8SODIUM1270mg/L25
E200.8STRONTIUM0.434mg/L0.4
E300.0BROMIDE3.1mg/L1.3
E300.0CHLORIDE485mg/L13
E300.0FLUORIDENDmg/L2.5U
E300.0NITRATE7.2mg/L0.25
E300.0NITRATE/NITRITE AS N7.2mg/L0.35
E300.0NITRITENDmg/L0.1U
E300.0SULFATE204mg/L13
E300.0SULFATE229mg/L50
FIELDpH, FIELD12.8SU
FIELDSPECIFIC CONDUCTIVITY, FIELD8780umhos/cm0.5
FIELDTEMPERATURE, FIELD21.7degrees C
RSK175ETHANE2.38mg/L0.016
RSK175METHANE4.02mg/L0.008
RSK175PROPANE1.48mg/L0.0022
SM1030CATION - ANION BALANCE0.64%
SM2320BBICARBONATE ALKALINITY as CACO3NDmg/L5U
SM2320BCARBONATE ALKALINITY AS CACO3365mg/L5
SM2320BTOTAL ALKALINITY AS CACO32330mg/L5
SM2510BSPECIFIC CONDUCTIVITY842umhos/cm1
SM2540CTOTAL DISSOLVED SOLIDS4170mg/L10
SM4500-H+ BpH, FIELD12.3SU
SM4500-H+ BpH, FIELD12.57SU
SW8015TEPH DIESEL RANGE ORGANICS137mg/L18
SW8015TVPH - Gasoline Range Organics16.5mg/L0.5
SW8260BENZENE1190ug/L25
SW8260ETHYLBENZENE54.6ug/L25
SW8260M-+P-XYLENE346ug/L25
SW8260o-XYLENE146ug/L25
SW8260TOLUENE1080ug/L25
SW8260TOTAL XYLENES492ug/L25