Sample ID: 669297 Sample Date: 12/10/2024 Matrix: GAS Collection Point: Dom Type: DGL Lab: Dolan Integration Group| Sample Results for Sample # 669297 Dolan Integration Group ID: DIG-038594 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | BUTANE | ND | MOL % | 0.005 | ND | | SOP | C6+ (hexanes +) | ND | MOL % | 0.005 | ND | | SOP | CARBON DIOXIDE | 1.23 | MOL % | 0.005 | | | SOP | DELTA 13C C1 | -79.9 | per mil | | | | SOP | DELTA D C1 | -339 | per mil | | | | SOP | ETHANE | ND | MOL % | 0.005 | ND | | SOP | ETHENE | ND | MOL % | 0.005 | ND | | SOP | ISOBUTANE | ND | MOL % | 0.005 | ND | | SOP | ISOPENTANE | ND | MOL % | 0.005 | ND | | SOP | METHANE | 12.07 | MOL % | 0.005 | | | SOP | NITROGEN (N2) | 81.19 | MOL % | 0.005 | | | SOP | OXYGEN + ARGON | 5.51 | MOL % | 0.005 | | | SOP | PENTANE | ND | MOL % | 0.005 | ND | | SOP | PROPANE | ND | MOL % | 0.005 | ND |
Sample ID: 669296 Sample Date: 12/10/2024 Matrix: WATER Collection Point: Dom Type: GW Lab: Origins| Sample Results for Sample # 669296 Origins ID: E4L0368-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | BART | BACTERIA, IRON RELATED | 0 | cfu/ml | | | | BART | BACTERIA, SLIME FORMING | 0 | cfu/ml | | | | BART | BACTERIA, SULFATE REDUCING | 0 | cfu/ml | | | | E200.8 | ARSENIC | ND | ug/L | 5 | ND | | E200.8 | BARIUM | 194 | ug/L | 4 | | | E200.8 | BORON | 88.2 | ug/L | 15 | | | E200.8 | CALCIUM | 22000 | ug/L | 200 | | | E200.8 | CHROMIUM | ND | ug/L | 10 | ND | | E200.8 | COPPER | 16 | ug/L | 2 | | | E200.8 | IRON | 292 | ug/L | 100 | | | E200.8 | LEAD | ND | ug/L | 2 | ND | | E200.8 | MAGNESIUM | 1650 | ug/L | 30 | | | E200.8 | MANGANESE | 87.9 | ug/L | 5 | | | E200.8 | POTASSIUM | 3260 | ug/L | 300 | | | E200.8 | SELENIUM | ND | ug/L | 5 | ND | | E200.8 | SODIUM | 179000 | ug/L | 1250 | | | E200.8 | STRONTIUM | 553 | ug/L | 10 | | | E200.8 | URANIUM | ND | ug/L | 0.2 | ND | | E300.0 | BROMIDE | 0.297 | mg/L | 0.1 | | | E300.0 | CHLORIDE | 19 | mg/L | 0.25 | | | E300.0 | FLUORIDE | 0.997 | mg/L | 0.1 | | | E300.0 | NITRATE | ND | mg/L | 0.033 | ND | | E300.0 | NITRITE | ND | mg/L | 0.033 | ND | | E300.0 | SULFATE | ND | mg/L | 0.25 | ND | | E353.2 | NITRATE/NITRITE | ND | mg/L | 0.02 | ND | | E365.4 | PHOSPHORUS | ND | mg/L | 0.2 | ND | | E903.1 | 226RADIUM | 0.427 | pCi/L | 1 | | | E903.1 | Radium 226 + Radium 228 | 2.09 | pCi/L | | | | E904.0 | 228RADIUM | 1.66 | pCi/L | 3 | | | RSK175 | ETHANE | ND | ug/L | 10 | ND | | RSK175 | METHANE | 1880 | ug/L | 10 | | | RSK175 | PROPANE | ND | ug/L | 10 | ND | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 428 | mg/L | 2 | | | SM2320B | Carbonate as CaCO3 | 2 | mg/L | 2 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 430 | mg/L | 2 | | | SM2510B | SPECIFIC CONDUCTIVITY | 756 | uS/cm | 5 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 550 | mg/L | 5 | | | SM4500-S2-F | SULFIDE | ND | mg/L | 0.4 | ND | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | ug/L | 209 | ND | | SW8015 | TVPH - Gasoline Range Organics | ND | ug/L | 100 | ND | | SW8260 | BENZENE | ND | ug/L | 1 | ND | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | ND | | SW8260 | M-+P-XYLENE | ND | ug/L | 2 | ND | | SW8260 | o-XYLENE | ND | ug/L | 1 | ND | | SW8260 | TOLUENE | ND | ug/L | 1 | ND | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | ND | | SW9040 | PH, LAB | 8.31 | pH Units | | |
Sample ID: 669298 Sample Date: 12/10/2024 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECH| Sample Results for Sample # 669298 ISOTECH ID: 949054 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | DELTA 13C DIC | -17.3 | ‰ | | | | SOP | DELTA 18O H2O | -13.5 | ‰ | | | | SOP | DELTA D H2O | -102.1 | ‰ | | |
Sample ID: 669299 Sample Date: 12/10/2024 Matrix: WATER Collection Point: TB Type: TB Lab: Origins| Sample Results for Sample # 669299 Origins ID: E4L0384-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8260 | BENZENE | ND | ug/L | 1 | ND | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | ND | | SW8260 | TOLUENE | ND | ug/L | 1 | ND | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | ND |
Sample ID: 633990 Sample Date: 12/09/2021 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECH| Sample Results for Sample # 633990 ISOTECH ID: 813773 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 1.18 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 129 | BTU | | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | | SOP | C6+ (hexanes +) | 0.0012 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 8.37 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -90.38 | ‰ | | | | SOP | DELTA D C1 | -313.1 | ‰ | | | | SOP | ETHANE | 0.0011 | mg/L | 0.0002 | | | SOP | ETHANE | 0.0023 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | HELIUM DILUTION FACTOR | 0.74 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | | SOP | METHANE | 3.1 | mg/L | 0.0002 | | | SOP | METHANE | 12.77 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 73.53 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 4.15 | MOL % | 0.01 | | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | | SOP | PROPANE | 0.00052 | mg/L | 0.0003 | | | SOP | PROPANE | 0.0008 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.971 | RATIO_AIR | | |
Sample ID: 633991 Sample Date: 12/09/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECH| Sample Results for Sample # 633991 ISOTECH ID: 810905 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | DELTA 13C DIC | -17.4 | ‰ | | | | SOP | DELTA 18O H2O | -13.48 | ‰ | | | | SOP | DELTA D H2O | -102.2 | ‰ | | |
Sample ID: 633992 Sample Date: 12/09/2021 Matrix: WATER Collection Point: TB Type: TB Lab: | Sample Results for Sample # 633992 ID: L1440733-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | M-+P-XYLENE | ND | mg/L | 0.002 | U | | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U |
Sample ID: 634000 Sample Date: 12/09/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: | Sample Results for Sample # 634000 ID: L1440731-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | BART | BACTERIA, IRON RELATED | | cfu/ml | | | | BART | BACTERIA, SLIME FORMING | | cfu/ml | | | | BART | BACTERIA, SULFATE REDUCING | | cfu/ml | | | | E245.1 | MERCURY | ND | mg/L | 0.0002 | U | | E353.2 | NITRATE/NITRITE | 45.7 | mg/L | 1 | | | E365.4 | PHOSPHORUS | ND | mg/L | 0.1 | U | | RSK-175 | ETHANE | ND | mg/L | 0.013 | U | | RSK-175 | METHANE | 2.78 | mg/L | 0.01 | | | RSK-175 | PROPANE | ND | mg/L | 0.02 | U | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 536 | mg/L | 20 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 536 | mg/L | 20 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 628 | mg/L | 10 | | | SW6020 | ALUMINUM | ND | mg/L | 0.1 | U | | SW6020 | ANTIMONY | ND | mg/L | 0.004 | U | | SW6020 | ARSENIC | ND | mg/L | 0.002 | U | | SW6020 | BARIUM | 0.156 | mg/L | 0.002 | | | SW6020 | BERYLLIUM | ND | mg/L | 0.002 | U | | SW6020 | BORON | 0.112 | mg/L | 0.03 | | | SW6020 | CADMIUM | ND | mg/L | 0.001 | U | | SW6020 | CALCIUM | 29.1 | mg/L | 1 | | | SW6020 | CHROMIUM | ND | mg/L | 0.002 | U | | SW6020 | COPPER | ND | mg/L | 0.005 | U | | SW6020 | IRON | ND | mg/L | 0.1 | U | | SW6020 | LEAD | ND | mg/L | 0.002 | U | | SW6020 | MAGNESIUM | 2.05 | mg/L | 1 | | | SW6020 | MANGANESE | 0.228 | mg/L | 0.005 | | | SW6020 | POTASSIUM | 3.08 | mg/L | 2 | | | SW6020 | SELENIUM | ND | mg/L | 0.002 | U | | SW6020 | SILVER | ND | mg/L | 0.002 | U | | SW6020 | SODIUM | 214 | mg/L | 2 | | | SW6020 | STRONTIUM | 0.56 | mg/L | 0.01 | | | SW6020 | THALLIUM | ND | mg/L | 0.002 | U | | SW6020 | URANIUM | ND | mg/L | 0.001 | U | | SW6020 | ZINC | ND | mg/L | 0.025 | U | | SW8015 | TEPH DIESEL RANGE ORGANICS | 0.344 | mg/L | 0.1 | J3 | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.1 | U | | SW846 8260B | 1,1,1-TRICHLOROETHANE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,1,2-TRICHLOROETHANE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,1-DICHLOROETHENE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,2,4-TRICHLOROBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,2-DICHLOROBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,2-DICHLOROETHANE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,2-DICHLOROPROPANE | ND | mg/L | 0.001 | U | | SW846 8260B | 1,4-DICHLOROBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | CARBON TETRACHLORIDE | ND | mg/L | 0.001 | U | | SW846 8260B | CHLOROBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | cis-1,2-DICHLOROETHENE | ND | mg/L | 0.001 | U | | SW846 8260B | DICHLOROMETHANE (methylene chloride) | ND | mg/L | 0.005 | U | | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | M-+P-XYLENE | ND | mg/L | 0.002 | U | | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | | SW846 8260B | STYRENE | ND | mg/L | 0.001 | U | | SW846 8260B | TETRACHLOROETHENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U | | SW846 8260B | trans-1,2-DICHLOROETHENE | ND | mg/L | 0.001 | U | | SW846 8260B | TRICHLOROETHENE | ND | mg/L | 0.001 | U | | SW846 8260B | VINYL CHLORIDE | ND | mg/L | 0.001 | U | | SW9040 | PH, LAB | 7.57 | SU | | T8 | | SW9040 | PH, LAB | 7.63 | SU | | T8 | | SW9050 | SPECIFIC CONDUCTIVITY | 1110 | UMHOS/CM | 10 | | | SW9056 | BROMIDE | ND | mg/L | 1 | U | | SW9056 | CHLORIDE | 24.5 | mg/L | 1 | | | SW9056 | FLUORIDE | 0.835 | mg/L | 0.15 | | | SW9056 | NITRATE | ND | mg/L | 0.1 | U | | SW9056 | NITRITE | ND | mg/L | 0.1 | U | | SW9056 | SULFATE | ND | mg/L | 5 | U | | SW9060 | TOTAL ORGANIC CARBON | 21.8 | mg/L | 5 | B |
Sample ID: 634001 Sample Date: 12/09/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: | Sample Results for Sample # 634001 ID: L1440731-02 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E900.0 | GROSS ALPHA | 11.7 | pCi/L | | | | E900.0 | GROSS BETA | 15.1 | pCi/L | | | | E904.0 | 228RADIUM | ND | pCi/L | | U | | SM7500-RN-B | 226RADIUM | 0.322 | pCi/L | | J |
Sample ID: 633993 Sample Date: 02/07/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: | Sample Results for Sample # 633993 ID: L1458986-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TEPH DIESEL RANGE ORGANICS | 0.15 | mg/L | 0.1 | |
|
|