Sample ID: 667215 Sample Date: 07/24/2024 Matrix: GAS Collection Point: SEP Type: SEP Lab: American Mobile Research| Sample Results for Sample # 667215 American Mobile Research ID: CR-88 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | ASTM D5504 | CARBON DISULFIDE | ND | mg/L | | < | | ASTM D5504 | HYDROGEN SULFIDE | 0.084 | mg/L | | | | ASTM D5504 | Sulfur Dioxide | ND | mg/L | | < |
Sample ID: 667218 Sample Date: 07/24/2024 Matrix: GAS Collection Point: SEP Type: SEP Lab: American Mobile Research| Sample Results for Sample # 667218 American Mobile Research ID: CR-91 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | GPA 2286 | 2,2,4-Trimethylpentane | 0.048 | MOL % | | | | GPA 2286 | Avg Molecular Weight | 27.0156 | gm/mole | | | | GPA 2286 | BENZENE | 0.031 | MOL % | | | | GPA 2286 | BRITISH THERMAL UNITS - SATURATED BASIS | 1523.77 | BTU | | | | GPA 2286 | BRITISH THERMAL UNITS- DRY BASIS | 1550.49 | BTU | | | | GPA 2286 | BUTANE | 4.481 | MOL % | | | | GPA 2286 | CARBON DIOXIDE | 2.212 | MOL % | | | | GPA 2286 | COMPRESSIBILITY | 0.993798 | No Unit | | | | GPA 2286 | CYCLOHEXANE | 0.08 | MOL % | | | | GPA 2286 | CYCLOPENTANE | 0.061 | MOL % | | | | GPA 2286 | DECANES + | 0.034 | MOL % | | | | GPA 2286 | ETHENE | 14.574 | MOL % | | | | GPA 2286 | ETHYLBENZENE | 0.006 | MOL % | | | | GPA 2286 | HEPTANES, MIXED ISOMERS | 0.441 | MOL % | | | | GPA 2286 | HYDROGEN SULFIDE | 0 | MOL % | | | | GPA 2286 | ISOBUTANE | 1.315 | MOL % | | | | GPA 2286 | ISOPENTANE | 0.936 | MOL % | | | | GPA 2286 | METHANE | 61.105 | MOL % | | | | GPA 2286 | METHYL CYCLOHEXANE | 0.083 | MOL % | | | | GPA 2286 | N-HEXANE | 0.245 | MOL % | | | | GPA 2286 | NITROGEN (N2) | 0.302 | MOL % | | | | GPA 2286 | NONANE | 0.012 | MOL % | | | | GPA 2286 | OCTANE, MIXED ISOMERS | 0.073 | MOL % | | | | GPA 2286 | Other Hexanes | 0.387 | MOL % | | | | GPA 2286 | PENTANE | 1.079 | MOL % | | | | GPA 2286 | PROPANE | 12.442 | MOL % | | | | GPA 2286 | Relative Density (air = 1) | 0.938594 | Ratio | | | | GPA 2286 | SPECIFIC GRAVITY | 0.932773 | RATIO_AIR | | | | GPA 2286 | TOLUENE | 0.024 | MOL % | | | | GPA 2286 | Total non gas liquids GPM | 10.5358 | gal/MCF | | | | GPA 2286 | TOTAL XYLENES | 0.029 | MOL % | | |
Sample ID: 667214 Sample Date: 07/24/2024 Matrix: GAS Collection Point: SEP Type: SEP Lab: American Mobile Research| Sample Results for Sample # 667214 American Mobile Research ID: CR-87 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | GPA 2286 | 2,2,4-Trimethylpentane | 0.024 | MOL % | | | | GPA 2286 | Avg Molecular Weight | 22.0558 | gm/mole | | | | GPA 2286 | BENZENE | 0.015 | MOL % | | | | GPA 2286 | BRITISH THERMAL UNITS - SATURATED BASIS | 1259.74 | BTU | | | | GPA 2286 | BRITISH THERMAL UNITS- DRY BASIS | 1281.79 | BTU | | | | GPA 2286 | BUTANE | 2.254 | MOL % | | | | GPA 2286 | CARBON DIOXIDE | 1.577 | MOL % | | | | GPA 2286 | COMPRESSIBILITY | 0.996103 | No Unit | | | | GPA 2286 | CYCLOHEXANE | 0.059 | MOL % | | | | GPA 2286 | CYCLOPENTANE | 0.036 | MOL % | | | | GPA 2286 | DECANES + | 0.009 | MOL % | | | | GPA 2286 | ETHENE | 8.416 | MOL % | | | | GPA 2286 | ETHYLBENZENE | 0.004 | MOL % | | | | GPA 2286 | HEPTANES, MIXED ISOMERS | 0.212 | MOL % | | | | GPA 2286 | HYDROGEN SULFIDE | 0 | MOL % | | | | GPA 2286 | ISOBUTANE | 0.648 | MOL % | | | | GPA 2286 | ISOPENTANE | 0.495 | MOL % | | | | GPA 2286 | METHANE | 77.803 | MOL % | | | | GPA 2286 | METHYL CYCLOHEXANE | 0.051 | MOL % | | | | GPA 2286 | N-HEXANE | 0.165 | MOL % | | | | GPA 2286 | NITROGEN (N2) | 1.132 | MOL % | | | | GPA 2286 | NONANE | 0.005 | MOL % | | | | GPA 2286 | OCTANE, MIXED ISOMERS | 0.033 | MOL % | | | | GPA 2286 | Other Hexanes | 0.27 | MOL % | | | | GPA 2286 | PENTANE | 0.588 | MOL % | | | | GPA 2286 | PROPANE | 6.175 | MOL % | | | | GPA 2286 | Relative Density (air = 1) | 0.764502 | Ratio | | | | GPA 2286 | SPECIFIC GRAVITY | 0.761523 | RATIO_AIR | | | | GPA 2286 | TOLUENE | 0.013 | MOL % | | | | GPA 2286 | Total non gas liquids GPM | 5.63543 | gal/MCF | | | | GPA 2286 | TOTAL XYLENES | 0.016 | MOL % | | |
Sample ID: 667219 Sample Date: 07/24/2024 Matrix: GAS Collection Point: SEP Type: SEP Lab: American Mobile Research| Sample Results for Sample # 667219 American Mobile Research ID: CR-92 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | ASTM D5504 | CARBON DISULFIDE | ND | mg/L | | < | | ASTM D5504 | HYDROGEN SULFIDE | 0.412 | mg/L | | | | ASTM D5504 | Sulfur Dioxide | ND | mg/L | | < |
Sample ID: 667221 Sample Date: 07/24/2024 Matrix: GAS Collection Point: SEP Type: SEP Lab: American Mobile Research| Sample Results for Sample # 667221 American Mobile Research ID: CR-90 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | ASTM D5504 | CARBON DISULFIDE | 0.512 | mg/L | | | | ASTM D5504 | HYDROGEN SULFIDE | 2.146 | mg/L | | | | ASTM D5504 | Sulfur Dioxide | ND | mg/L | | < |
Sample ID: 667220 Sample Date: 07/24/2024 Matrix: GAS Collection Point: SEP Type: SEP Lab: American Mobile Research| Sample Results for Sample # 667220 American Mobile Research ID: CR-89 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | GPA 2286 | 2,2,4-Trimethylpentane | 0.502 | MOL % | | | | GPA 2286 | Avg Molecular Weight | 51.571 | gm/mole | | | | GPA 2286 | BENZENE | 0.264 | MOL % | | | | GPA 2286 | BRITISH THERMAL UNITS - SATURATED BASIS | 2850.01 | BTU | | | | GPA 2286 | BRITISH THERMAL UNITS- DRY BASIS | 2900.21 | BTU | | | | GPA 2286 | BUTANE | 5.13 | MOL % | | | | GPA 2286 | CARBON DIOXIDE | 0.732 | MOL % | | | | GPA 2286 | COMPRESSIBILITY | 0.974075 | No Unit | | | | GPA 2286 | CYCLOHEXANE | 1.823 | MOL % | | | | GPA 2286 | CYCLOPENTANE | 0.217 | MOL % | | | | GPA 2286 | DECANES + | 0.094 | MOL % | | | | GPA 2286 | ETHENE | 19.976 | MOL % | | | | GPA 2286 | ETHYLBENZENE | 0.025 | MOL % | | | | GPA 2286 | HEPTANES, MIXED ISOMERS | 4.717 | MOL % | | | | GPA 2286 | HYDROGEN SULFIDE | 0 | MOL % | | | | GPA 2286 | ISOBUTANE | 3.407 | MOL % | | | | GPA 2286 | ISOPENTANE | 2.854 | MOL % | | | | GPA 2286 | METHANE | 12.64 | MOL % | | | | GPA 2286 | METHYL CYCLOHEXANE | 0.779 | MOL % | | | | GPA 2286 | N-HEXANE | 5.678 | MOL % | | | | GPA 2286 | NITROGEN (N2) | 3.859 | MOL % | | | | GPA 2286 | NONANE | 0.057 | MOL % | | | | GPA 2286 | OCTANE, MIXED ISOMERS | 0.62 | MOL % | | | | GPA 2286 | Other Hexanes | 8.97 | MOL % | | | | GPA 2286 | PENTANE | 3.934 | MOL % | | | | GPA 2286 | PROPANE | 23.142 | MOL % | | | | GPA 2286 | Relative Density (air = 1) | 1.82799 | Ratio | | | | GPA 2286 | SPECIFIC GRAVITY | 1.7806 | RATIO_AIR | | | | GPA 2286 | TOLUENE | 0.487 | MOL % | | | | GPA 2286 | Total non gas liquids GPM | 26.9714 | gal/MCF | | | | GPA 2286 | TOTAL XYLENES | 0.093 | MOL % | | |
Sample ID: 648228 Sample Date: 04/03/2023 Matrix: WATER Collection Point: Tank Type: PRDW Lab: | Sample Results for Sample # 648228 ID: L1601895-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | Ra226_Ra228 | 226RADIUM | 0.0589 | pCi/g | | | | Ra226_Ra228 | 228RADIUM | ND | pCi/g | | U |
Sample ID: 648231 Sample Date: 04/03/2023 Matrix: WATER Collection Point: Tank Type: PRDW Lab: | Sample Results for Sample # 648231 ID: L1601886-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 508 | mg/L | 20 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 508 | mg/L | 20 | | | SM4500-P | PHOSPHORUS | ND | mg/Kg | 200 | U | | SW6010 | BARIUM | 91.2 | mg/Kg | 0.5 | | | SW6010 | BORON | 24.4 | mg/Kg | 20 | | | SW6010 | CALCIUM | 792 | mg/Kg | 100 | | | SW6010 | IRON | 51.5 | mg/Kg | 10 | | | SW6010 | MAGNESIUM | ND | mg/Kg | 100 | U | | SW6010 | MANGANESE | ND | mg/Kg | 1 | U | | SW6010 | POTASSIUM | 183 | mg/Kg | 100 | | | SW6010 | SELENIUM | ND | mg/Kg | 2 | U | | SW6010 | SODIUM | 14900 | mg/Kg | 100 | | | SW6010 | STRONTIUM | 118 | mg/Kg | 1 | | | SW8015 | TVPH - Gasoline Range Organics | 33.6 | mg/Kg | 5 | | | SW846 8260B | BENZENE | 1.92 | mg/Kg | 0.08 | | | SW846 8260B | ETHYLBENZENE | 0.32 | mg/Kg | 0.2 | | | SW846 8260B | NAPHTHALENE | ND | mg/Kg | 1 | U | | SW846 8260B | TOLUENE | 1.57 | mg/Kg | 0.4 | | | SW846 8260B | TOTAL XYLENES | 1.47 | mg/Kg | 0.52 | | | SW9045 | PH, LAB | 6.76 | SU | | T8 | | SW9050 | SPECIFIC CONDUCTIVITY | 31200 | UMHOS/CM | 10 | | | SW9056 | BROMIDE | 224 | mg/Kg | 100 | | | SW9056 | CHLORIDE | 18900 | mg/Kg | 200 | | | SW9056 | FLUORIDE | ND | mg/Kg | 20 | U | | SW9056 | NITRATE | ND | mg/Kg | 100 | U | | SW9056 | NITRITE | ND | mg/Kg | 100 | U | | SW9056 | SULFATE | ND | mg/Kg | 500 | U |
Sample ID: 648235 Sample Date: 04/03/2023 Matrix: WATER Collection Point: Tank Type: PRDW Lab: | Sample Results for Sample # 648235 ID: L1601886-02 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 521 | mg/L | 20 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 521 | mg/L | 20 | | | SM4500-P | PHOSPHORUS | ND | mg/Kg | 200 | U | | SW6010 | BARIUM | 74.9 | mg/Kg | 0.5 | | | SW6010 | BORON | 20 | mg/Kg | 20 | | | SW6010 | CALCIUM | 657 | mg/Kg | 100 | | | SW6010 | IRON | 24.9 | mg/Kg | 10 | | | SW6010 | MAGNESIUM | ND | mg/Kg | 100 | U | | SW6010 | MANGANESE | ND | mg/Kg | 1 | U | | SW6010 | POTASSIUM | 173 | mg/Kg | 100 | | | SW6010 | SELENIUM | ND | mg/Kg | 2 | U | | SW6010 | SODIUM | 12300 | mg/Kg | 100 | | | SW6010 | STRONTIUM | 97.4 | mg/Kg | 1 | | | SW8015 | TVPH - Gasoline Range Organics | 22.5 | mg/Kg | 5 | | | SW846 8260B | BENZENE | 0.869 | mg/Kg | 0.008 | | | SW846 8260B | ETHYLBENZENE | 0.138 | mg/Kg | 0.02 | | | SW846 8260B | NAPHTHALENE | 0.518 | mg/Kg | 0.1 | | | SW846 8260B | TOLUENE | 0.664 | mg/Kg | 0.04 | | | SW846 8260B | TOTAL XYLENES | 0.742 | mg/Kg | 0.052 | | | SW9045 | PH, LAB | 6.67 | SU | | T8 | | SW9050 | SPECIFIC CONDUCTIVITY | 30700 | UMHOS/CM | 10 | | | SW9056 | BROMIDE | 233 | mg/Kg | 10.1 | | | SW9056 | CHLORIDE | 18800 | mg/Kg | 202 | | | SW9056 | FLUORIDE | ND | mg/Kg | 2.02 | U | | SW9056 | NITRATE | ND | mg/Kg | 10.1 | U | | SW9056 | NITRITE | ND | mg/Kg | 10.1 | U | | SW9056 | SULFATE | ND | mg/Kg | 50.5 | U |
Sample ID: 648233 Sample Date: 04/03/2023 Matrix: WATER Collection Point: Tank Type: PRDW Lab: | Sample Results for Sample # 648233 ID: L1601886-07 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | C10-C28 Diesel Range Organics | 1100 | mg/L | 20 | | | SW8015 | C28-C40 Oil Range Organics | 696 | mg/L | 20 | |
Sample ID: 648237 Sample Date: 04/03/2023 Matrix: WATER Collection Point: Tank Type: PRDW Lab: | Sample Results for Sample # 648237 ID: L1601886-08 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | C10-C28 Diesel Range Organics | 776 | mg/L | 20 | | | SW8015 | C28-C40 Oil Range Organics | 500 | mg/L | 20 | |
Sample ID: 648234 Sample Date: 04/03/2023 Matrix: WATER Collection Point: Tank Type: PRDW Lab: | Sample Results for Sample # 648234 ID: L1601895-03 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | Ra226_Ra228 | 226RADIUM | 0.0478 | pCi/g | | | | Ra226_Ra228 | 228RADIUM | ND | pCi/g | | U |
|
|