Sample Site ID249796
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSE 22 3N67W
Elevation4808Lat/Long40.20558/-104.87436
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-17599Well Name:MAYER 22-15L
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSE  22 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   655890     Sample Date:  10/26/2023     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 655890    ISOTECH ID: 896089
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0091MOL %0.005
SOPBRITISH THERMAL UNITS1263BTU
SOPBUTANE1.57MOL %0.0001
SOPC6+ (hexanes +)0.104MOL %0.0001
SOPCARBON DIOXIDE0.006MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.92
SOPDELTA 13C C2-32.33
SOPDELTA 13C C3-28.87
SOPDELTA 13C iC4-31.28
SOPDelta 13C iC5-28.18
SOPDELTA 13C nC4-27.79
SOPDelta 13C nC5-27.3
SOPDELTA D C1-248.2
SOPETHANE13.77MOL %0.0001
SOPETHENE0.0004MOL %0.0001
SOPHelium0.0085MOL %0.005
SOPHYDROGEN1.08MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.716MOL %0.0001
SOPISOPENTANE0.258MOL %0.0001
SOPMETHANE75.25MOL %0.0002
SOPNITROGEN (N2)0.9MOL %0.01
SOPOXYGEN (O2)0.16MOL %0.01
SOPPENTANE0.228MOL %0.0001
SOPPROPANE5.94MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.723RATIO_AIR

 Sample ID:   655886     Sample Date:  10/26/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 655886    ISOTECH ID: 896048
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.582MOL %0.005
SOPBRITISH THERMAL UNITS722BTU
SOPBUTANE0.398MOL %0.0001
SOPC6+ (hexanes +)0.105MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-59.01
SOPDELTA 13C C2-31.78
SOPDELTA 13C C3-26.83
SOPDELTA 13C iC4-30.9
SOPDelta 13C iC5-28.1
SOPDELTA 13C nC4-25.7
SOPDelta 13C nC5-26.3
SOPDELTA D C1-306.4
SOPETHANE5.31MOL %0.0001
SOPETHENE0.0026MOL %0.0001
SOPHELIUM DILUTION FACTOR0.81NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.29MOL %0.0001
SOPISOPENTANE0.102MOL %0.0001
SOPMETHANE52.44MOL %0.0002
SOPNITROGEN (N2)26.94MOL %0.01
SOPOXYGEN (O2)11.32MOL %0.01
SOPPENTANE0.0505MOL %0.0001
SOPPROPANE2.45MOL %0.0001
SOPPROPENE0.0058MOL %0.0001
SOPSPECIFIC GRAVITY0.797RATIO_AIR

 Sample ID:   655887     Sample Date:  10/26/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 655887    ISOTECH ID: 896048
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.38mg/L0.02
SOPETHANE2.8mg/L0.0003
SOPMETHANE14mg/L0.0003
SOPNITROGEN (N2)11mg/L0.02
SOPPROPANE1.8mg/L0.0004

 Sample ID:   655888     Sample Date:  10/26/2023     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 655888    Accutest ID: DA59659-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDpH, FIELD10.1SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1850umhos/cm0.5
FIELDTEMPERATURE, FIELD7.5degrees C
SW8015TVPH - Gasoline Range Organics0.753mg/L0.05
SW8260BENZENE92.7ug/L1
SW8260ETHYLBENZENE12.4ug/L1
SW8260M-+P-XYLENE76ug/L1
SW8260o-XYLENE0.69ug/L1J
SW8260TOLUENE3.9ug/L1
SW8260TOTAL XYLENES76.7ug/L1

 Sample ID:   655889     Sample Date:  10/26/2023     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 655889    Accutest ID: DA59660-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   624677     Sample Date:  03/09/2021     Matrix:  GAS     Collection Point:  PRD     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 624677    ISOTECH ID: 787845
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0052MOL %0.005
SOPBRITISH THERMAL UNITS1266BTU
SOPBUTANE1.48MOL %0.0001
SOPC6+ (hexanes +)0.0675MOL %0.0001
SOPCARBON DIOXIDE0.056MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.9
SOPDELTA 13C C2-32.5
SOPDELTA 13C C3-29
SOPDELTA 13C CO2-6
SOPDELTA 13C iC4-31.6
SOPDelta 13C iC5-28.3
SOPDELTA 13C nC4-27.9
SOPDelta 13C nC5-27.6
SOPDELTA D C1-240
SOPETHANE14.1MOL %0.0001
SOPETHENE0.0006MOL %0.0001
SOPHelium0.01MOL %0.005
SOPHYDROGEN0.955MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.718MOL %0.0001
SOPISOPENTANE0.235MOL %0.0001
SOPMETHANE75.65MOL %0.0002
SOPNITROGEN (N2)0.5MOL %0.01
SOPOXYGEN (O2)0.065MOL %0.01
SOPPENTANE0.195MOL %0.0001
SOPPROPANE5.96MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.72RATIO_AIR