Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#462953 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID462953
FacilityTypeOGProj Number
CountyWELD - 123LocationNENE 14 4N63W
Elevation4604Lat/Long40.31901/-104.39706
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-49899Well Name:Latham F11-J14-14HNB
Well Status:PROperator Name:BONANZA CREEK ENERGY OPERATING COMPANY LLC
Location:NENE  14 4N  63W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   651809     Sample Date:  09/05/2023     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 651809    SPL ID: 23090073-005A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1402BTU/cuft
SOPBUTANE2.44MOL %0.001
SOPCARBON DIOXIDE2.2068MOL %0.001
SOPETHENE13.6124MOL %0.001
SOPHEXANES1.9409MOL %0.001
SOPHYDROGEN SULFIDE0.0001MOL %
SOPISOBUTANE0.8028MOL %0.001
SOPISOPENTANE0.5142MOL %0.001
SOPMETHANE69.6069MOL %0.001
SOPNITROGEN (N2)0.464MOL %0.001
SOPPENTANE0.7275MOL %0.001
SOPPROPANE7.6844MOL %0.001
SOPSPECIFIC GRAVITY0.8442RATIO_AIR

 Sample ID:   641473     Sample Date:  09/01/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 641473    SPL ID: 22090038-001A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1354BTU/cuft
SOPBUTANE2.5491MOL %0.001
SOPCARBON DIOXIDE2.0554MOL %0.001
SOPETHENE13.6915MOL %0.001
SOPHEXANES0.6656MOL %0.001
SOPHYDROGEN SULFIDE0.0002MOL %
SOPISOBUTANE0.8732MOL %0.001
SOPISOPENTANE0.4709MOL %0.001
SOPMETHANE70.5486MOL %0.001
SOPNITROGEN (N2)0.5424MOL %0.001
SOPPENTANE0.609MOL %0.001
SOPPROPANE7.9941MOL %0.001
SOPSPECIFIC GRAVITY0.8114RATIO_AIR

 Sample ID:   636489     Sample Date:  03/30/2022     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 636489    SPL ID: 22040004-002A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1464BTU/cuft
SOPBUTANE3.4319MOL %0.001
SOPCARBON DIOXIDE1.9353MOL %0.001
SOPETHENE16.0385MOL %0.001
SOPHEXANES0.9052MOL %0.001
SOPHYDROGEN SULFIDE0.0002MOL %
SOPISOBUTANE1.1701MOL %0.001
SOPISOPENTANE0.6618MOL %0.001
SOPMETHANE64.1773MOL %0.001
SOPNITROGEN (N2)0.343MOL %0.001
SOPPENTANE0.8385MOL %0.001
SOPPROPANE10.4982MOL %0.001
SOPSPECIFIC GRAVITY0.8778RATIO_AIR