COGIS - Environmental Sample Site Information

 
#251108 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID251108
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSE 25 3N67W
Elevation4808Lat/Long40.19143/-104.835944
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-18911Well Name:HSR-MAGNESS 15-25
Well Status:SIOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSE  25 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   665505     Sample Date:  12/03/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 665505    ISOTECH ID: 947625
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.456MOL %0.005
SOPBRITISH THERMAL UNITS898BTU
SOPBUTANE0.97MOL %0.0001
SOPC6+ (hexanes +)0.127MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-51.36
SOPDELTA 13C C2-34.75
SOPDELTA 13C C3-30.29
SOPDELTA 13C iC4-32.2
SOPDelta 13C iC5-28.7
SOPDELTA 13C nC4-28.83
SOPDelta 13C nC5-28.6
SOPDELTA D C1-245.7
SOPETHANE8.92MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.75NA
SOPHYDROGENNDMOL %0.0025ND
SOPISOBUTANE0.348MOL %0.0001
SOPISOPENTANE0.221MOL %0.0001
SOPMETHANE57.08MOL %0.0002
SOPNITROGEN (N2)23.44MOL %0.01
SOPOXYGEN (O2)4.5MOL %0.01
SOPPENTANE0.199MOL %0.0001
SOPPROPANE3.75MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.789RATIO_AIR

 Sample ID:   665509     Sample Date:  12/03/2024     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 665509    ISOTECH ID: 948356
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1254BTU
SOPBUTANE1.9MOL %0.0001
SOPC6+ (hexanes +)0.0021MOL %0.0001
SOPCARBON DIOXIDE2.1MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.9
SOPDELTA 13C C2-32.07
SOPDELTA 13C C3-28.61
SOPDELTA 13C CO23.4
SOPDELTA 13C iC4-31.14
SOPDelta 13C iC5-28.11
SOPDELTA 13C nC4-27.76
SOPDelta 13C nC5-22.72
SOPDELTA D C1-242.1
SOPETHANE12.5MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0088MOL %0.0025
SOPHYDROGEN0.0025MOL %0.0025
SOPISOBUTANE0.768MOL %0.0001
SOPISOPENTANE0.551MOL %0.0001
SOPMETHANE76.12MOL %0.0002
SOPNITROGEN (N2)0.28MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.222MOL %0.0001
SOPPROPANE5.54MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.743RATIO_AIR

 Sample ID:   665506     Sample Date:  12/03/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 665506    ISOTECH ID: 947625
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.3mg/L0.01
SOPETHANE4.8mg/L0.0002
SOPMETHANE15mg/L0.0002
SOPNITROGEN (N2)9.5mg/L0.02
SOPPROPANE2.8mg/L0.0003

 Sample ID:   665508     Sample Date:  12/03/2024     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 665508    Accutest ID: DA69167-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   665507     Sample Date:  12/03/2024     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 665507    Accutest ID: DA69166-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E300.0BROMIDE0.3mg/L0.05
E300.0CHLORIDE74.7mg/L5
E300.0FLUORIDE2.3mg/L1
E300.0NITRATE0.19mg/L0.1
E300.0NITRATE/NITRITE AS N0.19mg/L0.14
E300.0NITRITENDmg/L0.04U
E300.0SULFATE0.81mg/L0.5
FIELDDISSOLVED OXYGEN, FIELDmg/L
FIELDOXIDATION REDUCTION POTENTIALmV
FIELDpH, FIELD10.7SU
FIELDSPECIFIC CONDUCTIVITY, FIELD757umhos/cm0.5
FIELDTEMPERATURE, FIELD10.4degrees C
FIELDTURBIDITYNTU
SW8015TVPH - Gasoline Range Organics1.91mg/L0.05
SW8260BENZENE99.9ug/L1
SW8260ETHYLBENZENE22.6ug/L1
SW8260M-+P-XYLENE175ug/L1
SW8260o-XYLENE70.6ug/L1
SW8260TOLUENE12.2ug/L1
SW8260TOTAL XYLENES246ug/L1

 Sample ID:   613493     Sample Date:  11/14/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 613493    ISOTECH ID: 742313
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.649MOL %0.005
SOPBRITISH THERMAL UNITS369BTU
SOPBUTANE0.61MOL %0.0001
SOPC6+ (hexanes +)0.0501MOL %0.0001
SOPCARBON DIOXIDE0.22MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.75
SOPDELTA 13C C2-33.86
SOPDELTA 13C C3-29.36
SOPDELTA 13C iC4-31.44
SOPDelta 13C iC5-28.14
SOPDELTA 13C nC4-27.98
SOPDelta 13C nC5-27.1
SOPDELTA D C1-238.5
SOPETHANE2.87MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0089MOL %0.005
SOPHYDROGEN0.0143MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.238MOL %0.0001
SOPISOPENTANE0.197MOL %0.0001
SOPMETHANE23.23MOL %0.0002
SOPNITROGEN (N2)55.42MOL %0.01
SOPOXYGEN (O2)14.85MOL %0.01
SOPPENTANE0.193MOL %0.0001
SOPPROPANE1.45MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.921RATIO_AIR

 Sample ID:   613494     Sample Date:  11/14/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 613494    ISOTECH ID: 742312
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0075MOL %0.005
SOPBRITISH THERMAL UNITS1260BTU
SOPBUTANE1.78MOL %0.0001
SOPC6+ (hexanes +)0.0519MOL %0.0001
SOPCARBON DIOXIDE2.07MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.87
SOPDELTA 13C C2-32.03
SOPDELTA 13C C3-28.61
SOPDELTA 13C CO23.41
SOPDELTA 13C iC4-31.1
SOPDelta 13C iC5-28.05
SOPDELTA 13C nC4-27.61
SOPDelta 13C nC5-27.03
SOPDELTA D C1-246.1
SOPETHANE13.8MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.008MOL %0.005
SOPHYDROGEN0.133MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.769MOL %0.0001
SOPISOPENTANE0.299MOL %0.0001
SOPMETHANE73.96MOL %0.0002
SOPNITROGEN (N2)0.77MOL %0.01
SOPOXYGEN (O2)0.011MOL %0.01
SOPPENTANE0.278MOL %0.0001
SOPPROPANE6.06MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.752RATIO_AIR

 Sample ID:   613491     Sample Date:  11/14/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 613491    Accutest ID: DA21999-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORON0.335mg/L0.05
E200.7CALCIUM2.48mg/L0.4
E200.7IRON0.246mg/L0.01
E200.7MAGNESIUMNDmg/L0.2U
E200.7MANGANESE0.007mg/L0.005
E200.7POTASSIUM6.13mg/L1
E200.7SODIUM259mg/L0.4
E200.7STRONTIUM0.079mg/L0.005
E200.8BARIUM0.591mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE0.7mg/L0.25
E300.0CHLORIDE128mg/L13
E300.0FLUORIDE3.5mg/L0.5
E300.0NITRATENDmg/L0.05U
E300.0Nitrite as NO2NDmg/L0.1U
E300.0SULFATENDmg/L2.5U
FIELDpH, FIELD10.4SU
FIELDSPECIFIC CONDUCTIVITY, FIELD651UMHOS/CM0.5
FIELDTEMPERATURE, FIELD18.1degrees C
SW8015TVPH - Gasoline Range Organics2.3mg/L0.05
SW8260BENZENE155ug/L1
SW8260ETHYLBENZENE43.2ug/L1
SW8260M-+P-XYLENE314ug/L1
SW8260o-XYLENE125ug/L1
SW8260TOLUENE99ug/L1
SW8260TOTAL XYLENES439ug/L1

 Sample ID:   613492     Sample Date:  11/14/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 613492    Accutest ID: DA22000-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   651018     Sample Date:  05/03/2023     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 651018    ISOTECH ID: 871528
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1257BTU
SOPBUTANE2.13MOL %0.0001
SOPC6+ (hexanes +)0.0021MOL %0.0001
SOPCARBON DIOXIDE2.23MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.2
SOPDELTA 13C C2-32.2
SOPDELTA 13C C3-28.7
SOPDELTA 13C CO23.6
SOPDELTA 13C iC4-31.3
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-28.1
SOPDelta 13C nC5-24
SOPDELTA D C1-245
SOPETHANE12.75MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0092MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.806MOL %0.0001
SOPISOPENTANE0.445MOL %0.0001
SOPMETHANE75.58MOL %0.0002
SOPNITROGEN (N2)0.33MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.235MOL %0.0001
SOPPROPANE5.48MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.747RATIO_AIR

 Sample ID:   651014     Sample Date:  05/03/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 651014    ISOTECH ID: 870106
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.469MOL %0.005
SOPBRITISH THERMAL UNITS772BTU
SOPBUTANE0.753MOL %0.0001
SOPC6+ (hexanes +)0.0432MOL %0.0001
SOPCARBON DIOXIDE0.02MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-50.78
SOPDELTA 13C C2-34.71
SOPDELTA 13C C3-30.2
SOPDELTA 13C iC4-32
SOPDelta 13C iC5-28.5
SOPDELTA 13C nC4-28.76
SOPDelta 13C nC5-28
SOPDELTA D C1-245
SOPETHANE7.81MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.63NA
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.277MOL %0.0001
SOPISOPENTANE0.141MOL %0.0001
SOPMETHANE49.87MOL %0.0002
SOPNITROGEN (N2)26.49MOL %0.01
SOPOXYGEN (O2)10.8MOL %0.01
SOPPENTANE0.116MOL %0.0001
SOPPROPANE3.21MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.817RATIO_AIR

 Sample ID:   651015     Sample Date:  05/03/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 651015    ISOTECH ID: 870106
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.48mg/L0.01
SOPETHANE6.5mg/L0.0002
SOPMETHANE21mg/L0.0002
SOPNITROGEN (N2)17mg/L0.02
SOPPROPANE3.7mg/L0.0003

 Sample ID:   651016     Sample Date:  05/03/2023     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 651016    Accutest ID: DA55219-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E300.0BROMIDE0.89mg/L0.1
E300.0FLUORIDE6.1mg/L0.2
E300.0NITRATE0.042mg/L0.02
E300.0NITRATE/NITRITE AS N0.042mg/L0.028
E300.0NITRITENDmg/L0.008U
E300.0SULFATE1.7mg/L1
FIELDpH, FIELD10.5SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1060UMHOS/CM0.5
FIELDTEMPERATURE, FIELD10.8degrees C
SW8015TEPH DIESEL RANGE ORGANICS2.32mg/L1
SW8015TVPH - Gasoline Range Organics2.14mg/L0.05
SW8260BENZENE147ug/L1
SW8260ETHYLBENZENE24.1ug/L1
SW8260M-+P-XYLENE191ug/L1
SW8260o-XYLENE77.4ug/L1
SW8260TOLUENE15.9ug/L1
SW8260TOTAL XYLENES268ug/L1

 Sample ID:   651017     Sample Date:  05/03/2023     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 651017    Accutest ID: DA55218-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U