Sample ID: 634125 Sample Date: 12/16/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 634125 ISOTECH ID: 811582 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.485 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 763 | BTU | | | | SOP | BUTANE | 0.283 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.114 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -68.57 | ‰ | | | | SOP | DELTA 13C C2 | -33.09 | ‰ | | | | SOP | DELTA 13C C3 | -28 | ‰ | | | | SOP | DELTA 13C iC4 | -30.7 | ‰ | | | | SOP | Delta 13C iC5 | -28.1 | ‰ | | | | SOP | DELTA 13C nC4 | -26.7 | ‰ | | | | SOP | Delta 13C nC5 | -25.8 | ‰ | | | | SOP | DELTA D C1 | -300.9 | ‰ | | | | SOP | ETHANE | 1.03 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0026 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.69 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.115 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0931 | MOL % | 0.0001 | | | SOP | METHANE | 69.52 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 24.35 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 3.34 | MOL % | 0.01 | | | SOP | PENTANE | 0.0781 | MOL % | 0.0001 | | | SOP | PROPANE | 0.581 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0042 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.699 | RATIO_AIR | | |
Sample ID: 634126 Sample Date: 12/16/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 634126 ISOTECH ID: 811582 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.41 | mg/L | 0.01 | | | SOP | ETHANE | 0.71 | mg/L | 0.0002 | | | SOP | METHANE | 24 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 13 | mg/L | 0.02 | | | SOP | PROPANE | 0.56 | mg/L | 0.0003 | |
Sample ID: 634129 Sample Date: 12/16/2021 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 634129 ISOTECH ID: 812170 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1234 | BTU | | | | SOP | BUTANE | 1.52 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0033 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.14 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.6 | ‰ | | | | SOP | DELTA 13C C2 | -31.7 | ‰ | | | | SOP | DELTA 13C C3 | -27.8 | ‰ | | | | SOP | DELTA 13C CO2 | 4.1 | ‰ | | | | SOP | DELTA 13C iC4 | -30.7 | ‰ | | | | SOP | Delta 13C iC5 | -27.4 | ‰ | | | | SOP | DELTA 13C nC4 | -27.1 | ‰ | | | | SOP | Delta 13C nC5 | -26.2 | ‰ | | | | SOP | DELTA D C1 | -239 | ‰ | | | | SOP | ETHANE | 13.03 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | 0.0077 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0589 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.759 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.128 | MOL % | 0.0001 | | | SOP | METHANE | 76.25 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.32 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.02 | MOL % | 0.01 | | | SOP | PENTANE | 0.0766 | MOL % | 0.0001 | | | SOP | PROPANE | 5.69 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.731 | RATIO_AIR | | |
Sample ID: 634127 Sample Date: 12/16/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 634127 Accutest ID: DA40154-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.0391 | mg/L | 0.004 | | | E200.8 | BORON | 0.69 | mg/L | 0.08 | | | E200.8 | CALCIUM | 1.55 | mg/L | 0.8 | | | E200.8 | IRON | 0.141 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.8 | MANGANESE | 0.0033 | mg/L | 0.002 | | | E200.8 | POTASSIUM | 2.36 | mg/L | 0.4 | | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | | E200.8 | SODIUM | 410 | mg/L | 7.5 | | | E200.8 | STRONTIUM | 0.0886 | mg/L | 0.04 | | | E300.0 | BROMIDE | 3.6 | mg/L | 0.1 | | | E300.0 | CHLORIDE | 594 | mg/L | 25 | | | E300.0 | FLUORIDE | 2.7 | mg/L | 0.2 | | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | | E300.0 | NITRITE | ND | mg/L | 0.04 | U | | E300.0 | SULFATE | 33.8 | mg/L | 1 | | | FIELD | pH, FIELD | 11.6 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 2330 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 8 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 11 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 160 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 239 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 10.9 | mg/L | 0.32 | | | SW8015 | TVPH - Gasoline Range Organics | 2 | mg/L | 0.05 | | | SW8260 | BENZENE | 131 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | 36.6 | ug/L | 5 | | | SW8260 | M-+P-XYLENE | 339 | ug/L | 5 | | | SW8260 | o-XYLENE | 15.7 | ug/L | 5 | | | SW8260 | TOLUENE | 41.1 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 355 | ug/L | 5 | |
Sample ID: 634128 Sample Date: 12/16/2021 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 634128 Accutest ID: DA40155-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 611793 Sample Date: 09/10/2019 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 611793 ISOTECH ID: 734117 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.661 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 309 | BTU | | | | SOP | BUTANE | 0.179 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0485 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.089 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -68.82 | ‰ | | | | SOP | DELTA 13C iC4 | -31.61 | ‰ | | | | SOP | Delta 13C iC5 | -27.94 | ‰ | | | | SOP | DELTA 13C nC4 | -27.14 | ‰ | | | | SOP | Delta 13C nC5 | -26.13 | ‰ | | | | SOP | DELTA D C1 | -311.6 | ‰ | | | | SOP | ETHANE | 0.382 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0004 | MOL % | 0.0001 | | | SOP | Helium | 0.0343 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0134 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.0765 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0835 | MOL % | 0.0001 | | | SOP | METHANE | 27.52 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 56.97 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 13.61 | MOL % | 0.01 | | | SOP | PENTANE | 0.0725 | MOL % | 0.0001 | | | SOP | PROPANE | 0.262 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0006 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.883 | RATIO_AIR | | |
Sample ID: 611794 Sample Date: 09/10/2019 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 611794 ISOTECH ID: 734116 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1267 | BTU | | | | SOP | BUTANE | 2.01 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0436 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.22 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.15 | ‰ | | | | SOP | DELTA 13C C2 | -31.26 | ‰ | | | | SOP | DELTA 13C C3 | -27.85 | ‰ | | | | SOP | DELTA 13C CO2 | 3.3 | ‰ | | | | SOP | DELTA 13C iC4 | -30.74 | ‰ | | | | SOP | Delta 13C iC5 | -27.72 | ‰ | | | | SOP | DELTA 13C nC4 | -27.24 | ‰ | | | | SOP | Delta 13C nC5 | -26.54 | ‰ | | | | SOP | DELTA D C1 | -239.6 | ‰ | | | | SOP | ETHANE | 13.11 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | 0.0073 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.028 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.85 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.375 | MOL % | 0.0001 | | | SOP | METHANE | 74.79 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.29 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.018 | MOL % | 0.01 | | | SOP | PENTANE | 0.324 | MOL % | 0.0001 | | | SOP | PROPANE | 5.93 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.754 | RATIO_AIR | | |
Sample ID: 611791 Sample Date: 09/10/2019 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 611791 Accutest ID: DA20112-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 0.763 | mg/L | 0.05 | | | E200.7 | CALCIUM | 2.11 | mg/L | 0.4 | | | E200.7 | IRON | 0.205 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | 0.0068 | mg/L | 0.005 | | | E200.7 | POTASSIUM | 3.54 | mg/L | 1 | | | E200.7 | SODIUM | 427 | mg/L | 0.4 | | | E200.7 | STRONTIUM | 0.0769 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0308 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.0133 | mg/L | 0.0008 | | | E300.0 | BROMIDE | 3.5 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 533 | mg/L | 25 | | | E300.0 | FLUORIDE | 2.9 | mg/L | 0.5 | | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.2 | U | | E300.0 | SULFATE | 32 | mg/L | 25 | | | FIELD | pH, FIELD | 10.8 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 2270 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 32.9 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 3.1 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 179 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 213 | mg/L | 5 | | | SW8015 | TVPH - Gasoline Range Organics | 2.05 | mg/L | 0.5 | | | SW8260 | BENZENE | 77.9 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | 25.8 | ug/L | 5 | | | SW8260 | M-+P-XYLENE | 283 | ug/L | 5 | | | SW8260 | o-XYLENE | 35.8 | ug/L | 5 | | | SW8260 | TOLUENE | 50.2 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 318 | ug/L | 5 | |
Sample ID: 611792 Sample Date: 09/10/2019 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 611792 Accutest ID: DA20113-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 650546 Sample Date: 04/19/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 650546 ISOTECH ID: 869592 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0399 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1025 | BTU | | | | SOP | BUTANE | 0.19 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0702 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.37 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -53.96 | ‰ | | | | SOP | DELTA 13C C2 | -33.59 | ‰ | | | | SOP | DELTA 13C C3 | -30.11 | ‰ | | | | SOP | DELTA 13C CO2 | -10.6 | ‰ | | | | SOP | DELTA 13C iC4 | -32.37 | ‰ | | | | SOP | Delta 13C iC5 | -28.7 | ‰ | | | | SOP | DELTA 13C nC4 | -29.25 | ‰ | | | | SOP | Delta 13C nC5 | -28.2 | ‰ | | | | SOP | DELTA D C1 | -241.4 | ‰ | | | | SOP | ETHANE | 4.03 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | 0.0764 | MOL % | 0.005 | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.0849 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0428 | MOL % | 0.0001 | | | SOP | METHANE | 89.92 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 4.1 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.029 | MOL % | 0.01 | | | SOP | PENTANE | 0.0427 | MOL % | 0.0001 | | | SOP | PROPANE | 1 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.611 | RATIO_AIR | | |
Sample ID: 650545 Sample Date: 04/19/2023 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 650545 Accutest ID: DA54833-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.595 | mg/L | 0.002 | | | E200.8 | BORON | 3.16 | mg/L | 0.04 | | | E200.8 | CALCIUM | 17.7 | mg/L | 0.4 | | | E200.8 | IRON | 2.62 | mg/L | 0.02 | | | E200.8 | MAGNESIUM | 3.55 | mg/L | 0.1 | | | E200.8 | MANGANESE | 0.159 | mg/L | 0.001 | | | E200.8 | POTASSIUM | 5.69 | mg/L | 0.2 | | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | | E200.8 | SODIUM | 1490 | mg/L | 25 | | | E200.8 | STRONTIUM | 1.88 | mg/L | 0.1 | | | E300.0 | BROMIDE | 16.6 | mg/L | 2.5 | | | E300.0 | CHLORIDE | 2150 | mg/L | 100 | | | E300.0 | FLUORIDE | 4.4 | mg/L | 0.5 | | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.45 | U | | E300.0 | NITRITE | ND | mg/L | 0.4 | U | | E300.0 | SULFATE | 35.3 | mg/L | 2.5 | | | FIELD | pH, FIELD | 8.1 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 21.4 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 11.6 | degrees C | | | | RSK175 | ETHANE | 1.71 | mg/L | 0.08 | | | RSK175 | METHANE | 11.1 | mg/L | 0.04 | | | RSK175 | PROPANE | 0.518 | mg/L | 0.11 | | | SM1030 | CATION - ANION BALANCE | 5.1 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 570 | mg/L | 5 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 5 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 570 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 7020 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 4660 | mg/L | 10 | | | SM4500-H+ B | pH, FIELD | 7.91 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 1.8 | mg/L | 0.2 | | | SW8015 | TVPH - Gasoline Range Organics | 8.82 | mg/L | 0.05 | | | SW8260 | BENZENE | 1410 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 106 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 755 | ug/L | 10 | | | SW8260 | o-XYLENE | 289 | ug/L | 10 | | | SW8260 | TOLUENE | 1890 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 1040 | ug/L | 10 | |
Sample ID: 650547 Sample Date: 04/19/2023 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 650547 Accutest ID: DA54832-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|