Sample ID: 613584 Sample Date: 11/21/2019 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 613584 ISOTECH ID: 743361 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.693 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1 | BTU | | | | SOP | BUTANE | 0.0027 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0007 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.13 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | ETHANE | 0.0101 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | Helium | ND | MOL % | 0.005 | ND | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.0013 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0008 | MOL % | 0.0001 | | | SOP | METHANE | 0.0434 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 80.19 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 18.92 | MOL % | 0.01 | | | SOP | PENTANE | 0.0007 | MOL % | 0.0001 | | | SOP | PROPANE | 0.0071 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.997 | RATIO_AIR | | |
Sample ID: 613583 Sample Date: 11/21/2019 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 613583 Accutest ID: DA22204-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 613582 Sample Date: 11/21/2019 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 613582 Accutest ID: DA22205-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 0.622 | mg/L | 0.05 | | | E200.7 | CALCIUM | 26.1 | mg/L | 0.4 | | | E200.7 | IRON | 0.95 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | | E200.7 | POTASSIUM | 77.7 | mg/L | 1 | | | E200.7 | SODIUM | 1030 | mg/L | 8 | | | E200.7 | STRONTIUM | 0.599 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0719 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.017 | mg/L | 0.002 | | | E300.0 | BROMIDE | 0.79 | mg/L | 0.5 | | | E300.0 | CHLORIDE | 169 | mg/L | 50 | | | E300.0 | FLUORIDE | 1.1 | mg/L | 1 | | | E300.0 | NITRATE | 6.7 | mg/L | 1 | | | E300.0 | Nitrite as NO2 | 2.7 | mg/L | 0.4 | | | E300.0 | SULFATE | 578 | mg/L | 50 | | | FIELD | pH, FIELD | 13.5 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 8710 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 7 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 0.02 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 357 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1560 | mg/L | 5 | | | SW8015 | TVPH - Gasoline Range Organics | 2.46 | mg/L | 0.5 | | | SW8260 | BENZENE | 56.8 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 21 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 142 | ug/L | 10 | | | SW8260 | o-XYLENE | 70.7 | ug/L | 10 | | | SW8260 | TOLUENE | 180 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 213 | ug/L | 10 | |
Sample ID: 630953 Sample Date: 10/12/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 630953 ISOTECH ID: 806522 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.358 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 927 | BTU | | | | SOP | BUTANE | 0.538 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0233 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.26 | ‰ | | | | SOP | DELTA 13C C2 | -31.51 | ‰ | | | | SOP | DELTA 13C C3 | -28.22 | ‰ | | | | SOP | DELTA 13C iC4 | -31.2 | ‰ | | | | SOP | Delta 13C iC5 | -27.9 | ‰ | | | | SOP | DELTA 13C nC4 | -27.5 | ‰ | | | | SOP | DELTA D C1 | -236.6 | ‰ | | | | SOP | ETHANE | 13.03 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0008 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.75 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.229 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0398 | MOL % | 0.0001 | | | SOP | METHANE | 56.44 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 22.72 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 2.86 | MOL % | 0.01 | | | SOP | PENTANE | 0.0367 | MOL % | 0.0001 | | | SOP | PROPANE | 3.72 | MOL % | 0.0001 | | | SOP | PROPENE | 0.002 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.779 | RATIO_AIR | | |
Sample ID: 630957 Sample Date: 10/12/2021 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 630957 ISOTECH ID: 806933 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1831 | BTU | | | | SOP | BUTANE | 8 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 1.66 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 1.75 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.2 | ‰ | | | | SOP | DELTA 13C C2 | -32.3 | ‰ | | | | SOP | DELTA 13C C3 | -29.1 | ‰ | | | | SOP | DELTA 13C CO2 | 3.7 | ‰ | | | | SOP | DELTA 13C iC4 | -31.6 | ‰ | | | | SOP | Delta 13C iC5 | -28.6 | ‰ | | | | SOP | DELTA 13C nC4 | -28.5 | ‰ | | | | SOP | Delta 13C nC5 | -27 | ‰ | | | | SOP | DELTA D C1 | -241 | ‰ | | | | SOP | ETHANE | 10.4 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0009 | MOL % | 0.0001 | | | SOP | Helium | 0.006 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0761 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 2.44 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 4.77 | MOL % | 0.0001 | | | SOP | METHANE | 57.11 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.27 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.012 | MOL % | 0.01 | | | SOP | PENTANE | 6.67 | MOL % | 0.0001 | | | SOP | PROPANE | 6.84 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 1.102 | RATIO_AIR | | |
Sample ID: 630956 Sample Date: 10/12/2021 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 630956 Accutest ID: DA38266-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 630954 Sample Date: 10/12/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 630954 ISOTECH ID: 806522 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.24 | mg/L | 0.01 | | | SOP | ETHANE | 7.2 | mg/L | 0.0002 | | | SOP | METHANE | 15 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 9.5 | mg/L | 0.02 | | | SOP | PROPANE | 2.9 | mg/L | 0.0003 | |
Sample ID: 630955 Sample Date: 10/12/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 630955 Accutest ID: DA38249-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.0751 | mg/L | 0.004 | | | E200.8 | BORON | 0.599 | mg/L | 0.08 | | | E200.8 | CALCIUM | 24.2 | mg/L | 0.8 | | | E200.8 | IRON | 1.02 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.8 | MANGANESE | ND | mg/L | 0.002 | U | | E200.8 | POTASSIUM | 87.7 | mg/L | 5 | | | E200.8 | SELENIUM | 0.0189 | mg/L | 0.0008 | | | E200.8 | SODIUM | 1080 | mg/L | 100 | | | E200.8 | STRONTIUM | 0.686 | mg/L | 0.04 | | | E300.0 | BROMIDE | ND | mg/L | 2.5 | U | | E300.0 | CHLORIDE | 223 | mg/L | 50 | | | E300.0 | FLUORIDE | 10.5 | mg/L | 10 | | | E300.0 | NITRATE | 6.1 | mg/L | 1 | | | E300.0 | NITRATE/NITRITE AS N | 6.7 | mg/L | 1.4 | | | E300.0 | NITRITE | 0.59 | mg/L | 0.4 | | | E300.0 | SULFATE | 672 | mg/L | 50 | | | FIELD | pH, FIELD | 11.7 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 8830 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 18 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 4.1 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 310 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1670 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 17.2 | mg/L | 0.19 | | | SW8015 | TVPH - Gasoline Range Organics | 1.89 | mg/L | 0.5 | | | SW8260 | BENZENE | 57.3 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 19.7 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 153 | ug/L | 10 | | | SW8260 | o-XYLENE | 74.1 | ug/L | 10 | | | SW8260 | TOLUENE | 159 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 227 | ug/L | 10 | |
Sample ID: 660557 Sample Date: 04/29/2024 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 660557 ISOTECH ID: 920655 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.23 | mg/L | 0.01 | | | SOP | ETHANE | 10 | mg/L | 0.0002 | | | SOP | METHANE | 20 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 9.1 | mg/L | 0.02 | | | SOP | PROPANE | 4.5 | mg/L | 0.0003 | |
Sample ID: 660556 Sample Date: 04/29/2024 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 660556 ISOTECH ID: 920655 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.285 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1047 | BTU | | | | SOP | BUTANE | 0.938 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0204 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | 0.073 | MOL % | 0.01 | | | SOP | DELTA 13C C1 | -43.93 | ‰ | | | | SOP | DELTA 13C C2 | -30.63 | ‰ | | | | SOP | DELTA 13C C3 | -27.91 | ‰ | | | | SOP | DELTA 13C iC4 | -31.1 | ‰ | | | | SOP | Delta 13C iC5 | -28.1 | ‰ | | | | SOP | DELTA 13C nC4 | -27.27 | ‰ | | | | SOP | Delta 13C nC5 | -27.5 | ‰ | | | | SOP | DELTA D C1 | -220.4 | ‰ | | | | SOP | ETHANE | 14.96 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | HELIUM DILUTION FACTOR | 0.68 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.0025 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.367 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.115 | MOL % | 0.0001 | | | SOP | METHANE | 59.66 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 17.87 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.75 | MOL % | 0.01 | | | SOP | PENTANE | 0.117 | MOL % | 0.0001 | | | SOP | PROPANE | 4.84 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0023 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.778 | RATIO_AIR | | |
Sample ID: 660560 Sample Date: 04/29/2024 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 660560 ISOTECH ID: 922372 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0066 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1350 | BTU | | | | SOP | BUTANE | 2.78 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.112 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 1.99 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.2 | ‰ | | | | SOP | DELTA 13C C2 | -32.5 | ‰ | | | | SOP | DELTA 13C C3 | -28.7 | ‰ | | | | SOP | DELTA 13C CO2 | 2.8 | ‰ | | | | SOP | DELTA 13C iC4 | -31.2 | ‰ | | | | SOP | Delta 13C iC5 | -28.4 | ‰ | | | | SOP | DELTA 13C nC4 | -28.1 | ‰ | | | | SOP | Delta 13C nC5 | -27.6 | ‰ | | | | SOP | DELTA D C1 | -243 | ‰ | | | | SOP | ETHANE | 14.47 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0009 | MOL % | 0.0001 | | | SOP | Helium | 0.0052 | MOL % | 0.0025 | | | SOP | HYDROGEN | 0.0436 | MOL % | 0.0025 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 1.15 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.713 | MOL % | 0.0001 | | | SOP | METHANE | 69.72 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.65 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.12 | MOL % | 0.01 | | | SOP | PENTANE | 0.812 | MOL % | 0.0001 | | | SOP | PROPANE | 7.42 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.808 | RATIO_AIR | | |
Sample ID: 660558 Sample Date: 04/29/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 660558 Accutest ID: DA64021-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.0789 | mg/L | 0.002 | | | E200.8 | BORON | 0.575 | mg/L | 0.04 | | | E200.8 | CALCIUM | 22.9 | mg/L | 2 | | | E200.8 | IRON | 0.478 | mg/L | 0.02 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.5 | U | | E200.8 | MANGANESE | 0.0029 | mg/L | 0.001 | | | E200.8 | POTASSIUM | 125 | mg/L | 2 | | | E200.8 | SELENIUM | 0.0157 | mg/L | 0.0004 | | | E200.8 | SODIUM | 1250 | mg/L | 20 | | | E200.8 | STRONTIUM | 0.639 | mg/L | 0.02 | | | E300.0 | BROMIDE | 0.59 | mg/L | 0.5 | | | E300.0 | CHLORIDE | 182 | mg/L | 5 | | | E300.0 | FLUORIDE | 3.2 | mg/L | 1 | | | E300.0 | NITRATE | 5.5 | mg/L | 1 | | | E300.0 | NITRITE | ND | mg/L | 0.04 | U | | E300.0 | SULFATE | 585 | mg/L | 50 | | | FIELD | pH, FIELD | 12.7 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 8950 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 17.5 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 21.6 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 900 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1000 | mg/L | 5 | | | SM2510B | SPECIFIC CONDUCTIVITY | 10200 | umhos/cm | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 3680 | mg/L | 10 | | | SM4500-H+ B | pH, FIELD | 13.21 | SU | | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 24.3 | mg/L | 2 | | | SW8015 | TVPH - Gasoline Range Organics | 4.61 | mg/L | 0.5 | | | SW8260 | BENZENE | 55.3 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 16.5 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 90.1 | ug/L | 10 | | | SW8260 | o-XYLENE | 50.3 | ug/L | 10 | | | SW8260 | TOLUENE | 126 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 140 | ug/L | 10 | |
Sample ID: 660559 Sample Date: 04/29/2024 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 660559 Accutest ID: DA64026-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 668739 Sample Date: 04/09/2025 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 668739 ISOTECH ID: 963593 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0517 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1193 | BTU | | | | SOP | BUTANE | 1.69 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.096 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48 | ‰ | | | | SOP | DELTA 13C C2 | -32.5 | ‰ | | | | SOP | DELTA 13C C3 | -28.8 | ‰ | | | | SOP | DELTA 13C iC4 | -31.1 | ‰ | | | | SOP | Delta 13C iC5 | -28.1 | ‰ | | | | SOP | DELTA 13C nC4 | -27.7 | ‰ | | | | SOP | Delta 13C nC5 | -27.1 | ‰ | | | | SOP | DELTA D C1 | -241 | ‰ | | | | SOP | ETHANE | 12.34 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0008 | MOL % | 0.0001 | | | SOP | Helium | 0.0103 | MOL % | 0.0025 | | | SOP | HYDROGEN | 0.124 | MOL % | 0.0025 | | | SOP | ISOBUTANE | 0.763 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.383 | MOL % | 0.0001 | | | SOP | METHANE | 70.85 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 7.27 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.61 | MOL % | 0.01 | | | SOP | PENTANE | 0.384 | MOL % | 0.0001 | | | SOP | PROPANE | 5.42 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0005 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.752 | RATIO_AIR | | |
Sample ID: 668740 Sample Date: 04/09/2025 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 668740 ISOTECH ID: 963592 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1240 | BTU | | | | SOP | BUTANE | 1.51 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0232 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.51 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.9 | ‰ | | | | SOP | DELTA 13C C2 | -32.6 | ‰ | | | | SOP | DELTA 13C C3 | -28.9 | ‰ | | | | SOP | DELTA 13C CO2 | 3.5 | ‰ | | | | SOP | DELTA 13C iC4 | -31.2 | ‰ | | | | SOP | Delta 13C iC5 | -28.1 | ‰ | | | | SOP | DELTA 13C nC4 | -27.8 | ‰ | | | | SOP | Delta 13C nC5 | -27 | ‰ | | | | SOP | DELTA D C1 | -242 | ‰ | | | | SOP | ETHANE | 13.68 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0014 | MOL % | 0.0001 | | | SOP | Helium | 0.0067 | MOL % | 0.0025 | | | SOP | HYDROGEN | 0.0144 | MOL % | 0.0025 | | | SOP | ISOBUTANE | 0.672 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.263 | MOL % | 0.0001 | | | SOP | METHANE | 75.26 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.3 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.034 | MOL % | 0.01 | | | SOP | PENTANE | 0.244 | MOL % | 0.0001 | | | SOP | PROPANE | 5.48 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.741 | RATIO_AIR | | |
Sample ID: 668737 Sample Date: 04/09/2025 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 668737 Accutest ID: DA71730-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.054 | mg/L | 0.002 | | | E200.8 | BORON | 0.51 | mg/L | 0.04 | | | E200.8 | CALCIUM | 17.2 | mg/L | 0.4 | | | E200.8 | IRON | 0.436 | mg/L | 0.02 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.1 | U | | E200.8 | MANGANESE | ND | mg/L | 0.05 | U | | E200.8 | POTASSIUM | 120 | mg/L | 10 | | | E200.8 | SELENIUM | 0.0129 | mg/L | 0.0004 | | | E200.8 | SODIUM | 1130 | mg/L | 25 | | | E200.8 | STRONTIUM | 0.534 | mg/L | 0.02 | | | E300.0 | BROMIDE | ND | mg/L | 1.3 | U | | E300.0 | CHLORIDE | 158 | mg/L | 13 | | | E300.0 | FLUORIDE | ND | mg/L | 2.5 | U | | E300.0 | NITRATE | 5.2 | mg/L | 0.25 | | | E300.0 | NITRATE/NITRITE AS N | 5.2 | mg/L | 0.35 | | | E300.0 | NITRITE | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | 565 | mg/L | 13 | | | FIELD | pH, FIELD | 13.1 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 7300 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 14.8 | degrees C | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 304 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1670 | mg/L | 5 | | | SW8015 | TVPH - Gasoline Range Organics | 2.81 | mg/L | 0.5 | | | SW8260 | BENZENE | 55.3 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 18.1 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 129 | ug/L | 10 | | | SW8260 | o-XYLENE | 63 | ug/L | 10 | | | SW8260 | TOLUENE | 157 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 192 | ug/L | 10 | |
Sample ID: 668738 Sample Date: 04/09/2025 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 668738 Accutest ID: DA71731-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 649138 Sample Date: 03/13/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 649138 ISOTECH ID: 862745 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.29 | mg/L | 0.02 | | | SOP | ETHANE | 12 | mg/L | 0.0002 | | | SOP | METHANE | 24 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 9.5 | mg/L | 0.02 | | | SOP | PROPANE | 7.4 | mg/L | 0.0003 | |
Sample ID: 649141 Sample Date: 03/13/2023 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 649141 ISOTECH ID: 863801 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1306 | BTU | | | | SOP | BUTANE | 2.21 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0185 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.49 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.8 | ‰ | | | | SOP | DELTA 13C C2 | -32.2 | ‰ | | | | SOP | DELTA 13C C3 | -28.4 | ‰ | | | | SOP | DELTA 13C CO2 | 3.7 | ‰ | | | | SOP | DELTA 13C iC4 | -31.4 | ‰ | | | | SOP | Delta 13C iC5 | -28.7 | ‰ | | | | SOP | DELTA 13C nC4 | -28.1 | ‰ | | | | SOP | Delta 13C nC5 | -27.2 | ‰ | | | | SOP | DELTA D C1 | -242 | ‰ | | | | SOP | ETHANE | 13.95 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0004 | MOL % | 0.0001 | | | SOP | Helium | 0.0077 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0271 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.955 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.624 | MOL % | 0.0001 | | | SOP | METHANE | 72.14 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.29 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | ND | MOL % | 0.01 | ND | | SOP | PENTANE | 0.67 | MOL % | 0.0001 | | | SOP | PROPANE | 6.62 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.782 | RATIO_AIR | | |
Sample ID: 649137 Sample Date: 03/13/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 649137 ISOTECH ID: 862745 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.275 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1155 | BTU | | | | SOP | BUTANE | 1.95 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.774 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.11 | ‰ | | | | SOP | DELTA 13C C2 | -31.85 | ‰ | | | | SOP | DELTA 13C C3 | -28.49 | ‰ | | | | SOP | DELTA 13C iC4 | -31.17 | ‰ | | | | SOP | Delta 13C iC5 | -28.23 | ‰ | | | | SOP | DELTA 13C nC4 | -27.6 | ‰ | | | | SOP | Delta 13C nC5 | -27.7 | ‰ | | | | SOP | DELTA D C1 | -226.8 | ‰ | | | | SOP | ETHANE | 14.32 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0006 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.65 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.794 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.501 | MOL % | 0.0001 | | | SOP | METHANE | 56.78 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 14.13 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 3.81 | MOL % | 0.01 | | | SOP | PENTANE | 0.551 | MOL % | 0.0001 | | | SOP | PROPANE | 6.11 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0011 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.843 | RATIO_AIR | | |
Sample ID: 649140 Sample Date: 03/13/2023 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 649140 Accutest ID: DA54000-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 649139 Sample Date: 03/13/2023 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 649139 Accutest ID: DA54001-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.0544 | mg/L | 0.02 | | | E200.8 | BORON | 0.425 | mg/L | 0.4 | | | E200.8 | CALCIUM | 13.8 | mg/L | 4 | | | E200.8 | IRON | 4.18 | mg/L | 0.2 | | | E200.8 | MAGNESIUM | ND | mg/L | 1 | U | | E200.8 | MANGANESE | 0.0517 | mg/L | 0.01 | | | E200.8 | POTASSIUM | 71.9 | mg/L | 2 | | | E200.8 | SELENIUM | 0.0101 | mg/L | 0.004 | | | E200.8 | SODIUM | 745 | mg/L | 15 | | | E200.8 | STRONTIUM | 0.38 | mg/L | 0.2 | | | E300.0 | BROMIDE | 0.45 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 136 | mg/L | 25 | | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.5 | | | E300.0 | NITRATE | 4.8 | mg/L | 0.5 | | | E300.0 | NITRATE/NITRITE AS N | 4.9 | mg/L | 0.52 | | | E300.0 | NITRITE | 0.067 | mg/L | 0.02 | | | E300.0 | SULFATE | 465 | mg/L | 25 | | | FIELD | pH, FIELD | 12.9 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 4710 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 10.2 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 5.2 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 280 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1240 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 17.5 | mg/L | 0.2 | | | SW8015 | TVPH - Gasoline Range Organics | 4.69 | mg/L | 0.5 | | | SW8260 | BENZENE | 79 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 71.6 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 491 | ug/L | 10 | | | SW8260 | o-XYLENE | 171 | ug/L | 10 | | | SW8260 | TOLUENE | 592 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 662 | ug/L | 10 | |
|
|