|
|
Sample ID: 613704 Sample Date: 12/09/2019 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 613704 ISOTECH ID: 744769 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.919 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 475 | BTU | | | | SOP | BUTANE | 0.451 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0425 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.019 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.08 | ‰ | | | | SOP | DELTA 13C C2 | -31.71 | ‰ | | | | SOP | DELTA 13C C3 | -31.17 | ‰ | | | | SOP | DELTA D C1 | -230.8 | ‰ | | | | SOP | ETHANE | 4.47 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0017 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.71 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.198 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0723 | MOL % | 0.0001 | | | SOP | METHANE | 31.13 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 55.89 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 4.69 | MOL % | 0.01 | | | SOP | PENTANE | 0.0703 | MOL % | 0.0001 | | | SOP | PROPANE | 2.04 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0017 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.873 | RATIO_AIR | | |
Sample ID: 613706 Sample Date: 12/09/2019 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 613706 ISOTECH ID: 745157 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1289 | BTU | | | | SOP | BUTANE | 1.98 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.018 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.41 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.29 | ‰ | | | | SOP | DELTA 13C C2 | -31.41 | ‰ | | | | SOP | DELTA 13C C3 | -28.03 | ‰ | | | | SOP | DELTA 13C CO2 | 3.41 | ‰ | | | | SOP | DELTA 13C iC4 | -30.81 | ‰ | | | | SOP | Delta 13C iC5 | -28.06 | ‰ | | | | SOP | DELTA 13C nC4 | -27.21 | ‰ | | | | SOP | Delta 13C nC5 | -26.8 | ‰ | | | | SOP | DELTA D C1 | -239.9 | ‰ | | | | SOP | ETHANE | 14.22 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0008 | MOL % | 0.0001 | | | SOP | Helium | 0.0066 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0377 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.892 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.528 | MOL % | 0.0001 | | | SOP | METHANE | 72.77 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.34 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.022 | MOL % | 0.01 | | | SOP | PENTANE | 0.548 | MOL % | 0.0001 | | | SOP | PROPANE | 6.23 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.771 | RATIO_AIR | | |
Sample ID: 613705 Sample Date: 12/09/2019 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 613705 ISOTECH ID: 744769 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.89 | mg/L | 0.02 | | | SOP | ETHANE | 3.5 | mg/L | 0.0003 | | | SOP | METHANE | 12 | mg/L | 0.0003 | | | SOP | NITROGEN (N2) | 35 | mg/L | 0.02 | | | SOP | PROPANE | 2.2 | mg/L | 0.0004 | |
Sample ID: 636340 Sample Date: 03/14/2022 Matrix: GAS Collection Point: PRD Type: PCS Lab: ISOTECH| Sample Results for Sample # 636340 ISOTECH ID: 821599 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1283 | BTU | | | | SOP | BUTANE | 2.1 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0485 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.5 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.5 | ‰ | | | | SOP | DELTA 13C C2 | -32 | ‰ | | | | SOP | DELTA 13C C3 | -28.3 | ‰ | | | | SOP | DELTA 13C CO2 | 3.5 | ‰ | | | | SOP | DELTA 13C iC4 | -30.9 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -27.6 | ‰ | | | | SOP | Delta 13C nC5 | -27 | ‰ | | | | SOP | DELTA D C1 | -239 | ‰ | | | | SOP | ETHANE | 13.55 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0003 | MOL % | 0.0001 | | | SOP | Helium | 0.009 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.102 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.924 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.442 | MOL % | 0.0001 | | | SOP | METHANE | 73.25 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.3 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | ND | MOL % | 0.01 | ND | | SOP | PENTANE | 0.441 | MOL % | 0.0001 | | | SOP | PROPANE | 6.33 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.768 | RATIO_AIR | | |
Sample ID: 636341 Sample Date: 03/14/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 636341 ISOTECH ID: 821839 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.559 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 842 | BTU | | | | SOP | BUTANE | 0.744 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.099 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.93 | ‰ | | | | SOP | DELTA 13C C2 | -31.82 | ‰ | | | | SOP | DELTA 13C C3 | -29.46 | ‰ | | | | SOP | DELTA 13C iC4 | -31.2 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -28.18 | ‰ | | | | SOP | Delta 13C nC5 | -27.5 | ‰ | | | | SOP | DELTA D C1 | -229.6 | ‰ | | | | SOP | ETHANE | 7.75 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0021 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.67 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.331 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.107 | MOL % | 0.0001 | | | SOP | METHANE | 56.18 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 28.76 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 1.96 | MOL % | 0.01 | | | SOP | PENTANE | 0.105 | MOL % | 0.0001 | | | SOP | PROPANE | 3.4 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0024 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.781 | RATIO_AIR | | |
Sample ID: 636342 Sample Date: 03/14/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 636342 ISOTECH ID: 821839 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.52 | mg/L | 0.01 | | | SOP | ETHANE | 5.8 | mg/L | 0.0002 | | | SOP | METHANE | 21 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 17 | mg/L | 0.02 | | | SOP | PROPANE | 3.5 | mg/L | 0.0003 | |
Sample ID: 636344 Sample Date: 03/14/2022 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 636344 Accutest ID: DA42864-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 636343 Sample Date: 03/14/2022 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 636343 Accutest ID: DA42863-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.0949 | mg/L | 0.004 | | | E200.8 | BORON | 0.227 | mg/L | 0.08 | | | E200.8 | CALCIUM | ND | mg/L | 20 | U | | E200.8 | IRON | 3.58 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 5 | U | | E200.8 | MANGANESE | 0.0041 | mg/L | 0.002 | | | E200.8 | POTASSIUM | 691 | mg/L | 10 | | | E200.8 | SELENIUM | 0.0254 | mg/L | 0.0008 | | | E200.8 | SODIUM | 1280 | mg/L | 38 | | | E200.8 | STRONTIUM | 0.996 | mg/L | 0.04 | | | E300.0 | BROMIDE | 2 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 231 | mg/L | 25 | | | E300.0 | FLUORIDE | ND | mg/L | 5 | U | | E300.0 | NITRATE | 206 | mg/L | 6.3 | | | E300.0 | NITRITE | ND | mg/L | 0.2 | U | | E300.0 | SULFATE | 629 | mg/L | 25 | | | FIELD | pH, FIELD | 13.6 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 18000 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 10.9 | degrees C | | | | SW8015 | TVPH - Gasoline Range Organics | 5.55 | mg/L | 0.5 | | | SW8260 | BENZENE | 221 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 37.5 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 428 | ug/L | 10 | | | SW8260 | o-XYLENE | 154 | ug/L | 10 | | | SW8260 | TOLUENE | 674 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 582 | ug/L | 10 | |
Sample ID: 648686 Sample Date: 03/02/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 648686 ISOTECH ID: 862372 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.611 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 986 | BTU | | | | SOP | BUTANE | 1.32 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 1.65 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.59 | ‰ | | | | SOP | DELTA 13C C2 | -31.74 | ‰ | | | | SOP | DELTA 13C C3 | -29.44 | ‰ | | | | SOP | DELTA 13C iC4 | -32 | ‰ | | | | SOP | Delta 13C iC5 | -28.5 | ‰ | | | | SOP | DELTA 13C nC4 | -28.7 | ‰ | | | | SOP | Delta 13C nC5 | -28.3 | ‰ | | | | SOP | DELTA D C1 | -221.6 | ‰ | | | | SOP | ETHANE | 8.22 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0023 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.7 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.487 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.522 | MOL % | 0.0001 | | | SOP | METHANE | 54.23 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 24.82 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 3.43 | MOL % | 0.01 | | | SOP | PENTANE | 0.774 | MOL % | 0.0001 | | | SOP | PROPANE | 3.93 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0023 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.85 | RATIO_AIR | | |
Sample ID: 648690 Sample Date: 03/02/2023 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 648690 ISOTECH ID: 861961 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0832 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1124 | BTU | | | | SOP | BUTANE | 1.32 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0934 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.29 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.1 | ‰ | | | | SOP | DELTA 13C C2 | -31.7 | ‰ | | | | SOP | DELTA 13C C3 | -28.5 | ‰ | | | | SOP | DELTA 13C CO2 | 3.3 | ‰ | | | | SOP | DELTA 13C iC4 | -30.6 | ‰ | | | | SOP | Delta 13C iC5 | -28 | ‰ | | | | SOP | DELTA 13C nC4 | -27.6 | ‰ | | | | SOP | Delta 13C nC5 | -27.2 | ‰ | | | | SOP | DELTA D C1 | -236 | ‰ | | | | SOP | ETHANE | 12.18 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0002 | MOL % | 0.0001 | | | SOP | Helium | 0.0073 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0942 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.64 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.232 | MOL % | 0.0001 | | | SOP | METHANE | 68.24 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 7.53 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 2.03 | MOL % | 0.01 | | | SOP | PENTANE | 0.218 | MOL % | 0.0001 | | | SOP | PROPANE | 5.04 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.766 | RATIO_AIR | | |
Sample ID: 648687 Sample Date: 03/02/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 648687 ISOTECH ID: 862372 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.45 | mg/L | 0.01 | | | SOP | ETHANE | 5 | mg/L | 0.0002 | | | SOP | METHANE | 16 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 11 | mg/L | 0.02 | | | SOP | PROPANE | 3.3 | mg/L | 0.0003 | |
Sample ID: 648688 Sample Date: 03/02/2023 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 648688 Accutest ID: DA53740-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | FIELD | pH, FIELD | 13.9 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 16100 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 7.8 | degrees C | | | | SW8015 | TVPH - Gasoline Range Organics | 17.6 | mg/L | 0.5 | | | SW8260 | BENZENE | 560 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 216 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 2640 | ug/L | 10 | | | SW8260 | o-XYLENE | 572 | ug/L | 10 | | | SW8260 | TOLUENE | 2790 | ug/L | 100 | | | SW8260 | TOTAL XYLENES | 3220 | ug/L | 10 | |
Sample ID: 648689 Sample Date: 03/02/2023 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 648689 Accutest ID: DA53739-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | 0.73 | ug/L | 1 | J | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 623763 Sample Date: 02/09/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 623763 ISOTECH ID: 783806 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.791 | MOL % | 0.005 | | | SOP | ARGON | 0.87 | mg/L | 0.01 | | | SOP | BRITISH THERMAL UNITS | 566 | BTU | | | | SOP | BUTANE | 0.525 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0457 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.58 | ‰ | | | | SOP | DELTA 13C C2 | -31.82 | ‰ | | | | SOP | DELTA 13C C3 | -29.49 | ‰ | | | | SOP | DELTA 13C iC4 | -31.9 | ‰ | | | | SOP | Delta 13C iC5 | -28 | ‰ | | | | SOP | DELTA 13C nC4 | -28.8 | ‰ | | | | SOP | Delta 13C nC5 | -26.6 | ‰ | | | | SOP | DELTA D C1 | -213.6 | ‰ | | | | SOP | ETHANE | 4.8 | mg/L | 0.0002 | | | SOP | ETHANE | 5.36 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0016 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.61 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.225 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0709 | MOL % | 0.0001 | | | SOP | METHANE | 17 | mg/L | 0.0002 | | | SOP | METHANE | 37.18 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 32 | mg/L | 0.02 | | | SOP | NITROGEN (N2) | 46.44 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 6.86 | MOL % | 0.01 | | | SOP | PENTANE | 0.0704 | MOL % | 0.0001 | | | SOP | PROPANE | 2.43 | MOL % | 0.0001 | | | SOP | PROPANE | 3 | mg/L | 0.0003 | | | SOP | PROPENE | 0.0018 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.854 | RATIO_AIR | | |
Sample ID: 623766 Sample Date: 02/09/2021 Matrix: GAS Collection Point: PRDC Type: PCS Lab: Dolan Integration Group| Sample Results for Sample # 623766 Dolan Integration Group ID: DIG-024804 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | BRITISH THERMAL UNITS | 1191 | BTU/cuft | | | | SOP | BUTANE | 1.24 | MOL % | 0.005 | | | SOP | C6+ (hexanes +) | 0.02 | MOL % | 0.005 | | | SOP | CARBON DIOXIDE | 2.43 | MOL % | 0.005 | | | SOP | DELTA 13C C1 | -47.5 | per mil | | | | SOP | DELTA 13C C2 | -31.4 | per mil | | | | SOP | DELTA 13C C3 | -27.8 | per mil | | | | SOP | DELTA 13C CO2 | 2.4 | per mil | | | | SOP | DELTA 13C iC4 | -31.1 | per mil | | | | SOP | DELTA 13C nC4 | -28.1 | per mil | | | | SOP | DELTA D C1 | -240 | per mil | | | | SOP | ETHANE | 12.29 | MOL % | 0.005 | | | SOP | ETHENE | ND | MOL % | 0.005 | ND | | SOP | Helium | 0.02 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.04 | MOL % | 0.005 | | | SOP | ISOBUTANE | 0.59 | MOL % | 0.005 | | | SOP | ISOPENTANE | 0.23 | MOL % | 0.005 | | | SOP | METHANE | 76.86 | MOL % | 0.005 | | | SOP | NITROGEN (N2) | 1.18 | MOL % | 0.005 | | | SOP | OXYGEN + ARGON | 0.2 | MOL % | 0.005 | | | SOP | PENTANE | 0.22 | MOL % | 0.005 | | | SOP | PROPANE | 4.66 | MOL % | 0.005 | | | SOP | SPECIFIC GRAVITY | 0.724 | No Unit | | |
Sample ID: 623764 Sample Date: 02/09/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 623764 Accutest ID: DA32424-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 0.235 | mg/L | 0.05 | | | E200.7 | CALCIUM | 18.2 | mg/L | 0.4 | | | E200.7 | IRON | 3.36 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | | E200.7 | POTASSIUM | 738 | mg/L | 1 | | | E200.7 | SODIUM | 2070 | mg/L | 8 | | | E200.7 | STRONTIUM | 0.964 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0836 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.0307 | mg/L | 0.0008 | | | E300.0 | BROMIDE | ND | mg/L | 5 | U | | E300.0 | CHLORIDE | 258 | mg/L | 50 | | | E300.0 | FLUORIDE | 12.9 | mg/L | 10 | | | E300.0 | NITRATE | 218 | mg/L | 10 | | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.4 | U | | E300.0 | SULFATE | 645 | mg/L | 50 | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 17200 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 4 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 0.49 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 640 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 3700 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 3.63 | mg/L | 0.36 | | | SW8015 | TVPH - Gasoline Range Organics | 4.47 | mg/L | 0.5 | | | SW8260 | BENZENE | 236 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 37 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 415 | ug/L | 10 | | | SW8260 | o-XYLENE | 155 | ug/L | 10 | | | SW8260 | TOLUENE | 623 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 570 | ug/L | 10 | |
Sample ID: 623765 Sample Date: 02/09/2021 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 623765 Accutest ID: DA32425-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|