Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#202812 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID202812
FacilityTypeOGProj Number
CountyADAMS - 001LocationSWNW 35 1S66W
Elevation5153Lat/Long39.923302/-104.750064
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-001-08217Well Name:CHAMPLIN 117 AMOCO G 5
Well Status:PAOperator Name:PDC ENERGY INC
Location:SWNW  35 1S  66W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   627718     Sample Date:  07/15/2021     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ALS

Sample Results for Sample # 627718    ALS ID: 2107306-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM2.3mg/L1
E200.7MAGNESIUMNDmg/L1U
E200.7POTASSIUM590mg/L10
E200.7SODIUM880mg/L10
E300.0CHLORIDE1900mg/L20
E300.0SULFATENDmg/L50U
RSK175ETHANE2500ug/L4
RSK175METHANE14000ug/L1
RSK175PROPANE1200ug/L1
SM2320BBICARBONATE ALKALINITY as CACO3280mg/L20
SM2320BCARBONATE ALKALINITY AS CACO394mg/L20
SM2320BTOTAL ALKALINITY AS CACO3370mg/L20
SM2540CTOTAL DISSOLVED SOLIDS3600mg/L80
SW8015TEPH DIESEL RANGE ORGANICS28mg/L1.1
SW8015TVPH - Gasoline Range Organics16mg/L2
SW8260BENZENE2100ug/L100
SW8260ETHYLBENZENE230ug/L100
SW8260M-+P-XYLENE2100ug/L100
SW8260o-XYLENE730ug/L100
SW8260TOLUENE2800ug/L100
SW8260TOTAL XYLENES2800ug/L1

 Sample ID:   635771     Sample Date:  04/13/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ALS

Sample Results for Sample # 635771    ALS ID: 2204237-2
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM1.6mg/L1
E200.7MAGNESIUMNDmg/L1U
E200.7POTASSIUM530mg/L10
E200.7SODIUM870mg/L10

 Sample ID:   635770     Sample Date:  04/13/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ALS

Sample Results for Sample # 635770    ALS ID: 2204237-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM2mg/L1
E200.7MAGNESIUMNDmg/L1U
E200.7POTASSIUM510mg/L10
E200.7SODIUM840mg/L10
E300.0CHLORIDE1600mg/L40
E300.0SULFATENDmg/L50U
RSK175ETHANE9300ug/L20
RSK175METHANE29000ug/L10
RSK175PROPANE5200ug/L10
SM2320BBICARBONATE ALKALINITY as CACO3290mg/L20
SM2320BCARBONATE ALKALINITY AS CACO399mg/L20
SM2320BTOTAL ALKALINITY AS CACO3390mg/L20
SM2540CTOTAL DISSOLVED SOLIDS3400mg/L80
SW8015TEPH DIESEL RANGE ORGANICS28mg/L1
SW8015TVPH - Gasoline Range Organics22mg/L5
SW8260BENZENE2800ug/L100
SW8260ETHYLBENZENE270ug/L100
SW8260M-+P-XYLENE2400ug/L100
SW8260o-XYLENE790ug/L100
SW8260TOLUENE3500ug/L100
SW8260TOTAL XYLENES3200ug/L1

 Sample ID:   645708     Sample Date:  01/12/2023     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 645708    Dolan Integration Group ID: DIG-030703
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1127BTU/cuft
SOPBUTANE0.689MOL %0.005
SOPC6+ (hexanes +)NDMOL %0.005ND
SOPCARBON DIOXIDE1.928MOL %0.005
SOPDELTA 13C C1-50.6per mil
SOPDELTA 13C C2-34.2per mil
SOPDELTA 13C C3-30.5per mil
SOPDELTA 13C CO20.1per mil
SOPDELTA D C1-273per mil
SOPETHANE12.23MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.039MOL %0.005
SOPISOBUTANE0.337MOL %0.005
SOPISOPENTANE0.08MOL %0.005
SOPMETHANE75.586MOL %0.005
SOPNITROGEN (N2)4.06MOL %0.005
SOPOXYGEN + ARGON0.696MOL %0.005
SOPPENTANE0.051MOL %0.005
SOPPROPANE4.305MOL %0.005
SOPSPECIFIC GRAVITY0.711No Unit

 Sample ID:   645707     Sample Date:  01/12/2023     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 645707    Dolan Integration Group ID: DIG-030702
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1137BTU/cuft
SOPBUTANE0.612MOL %0.005
SOPC6+ (hexanes +)0.078MOL %0.005
SOPCARBON DIOXIDE0.05MOL %0.005
SOPDELTA 13C C1-52.3per mil
SOPDELTA 13C C2-34.1per mil
SOPDELTA 13C C3-30.7per mil
SOPDELTA D C1-323per mil
SOPETHANE8.928MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.012MOL %0.005
SOPISOBUTANE0.296MOL %0.005
SOPISOPENTANE0.106MOL %0.005
SOPMETHANE84.55MOL %0.005
SOPNITROGEN (N2)1.734MOL %0.005
SOPOXYGEN + ARGON0.207MOL %0.005
SOPPENTANE0.085MOL %0.005
SOPPROPANE3.342MOL %0.005
SOPSPECIFIC GRAVITY0.657No Unit

 Sample ID:   646085     Sample Date:  01/12/2023     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ALS Houston

Sample Results for Sample # 646085    ALS Houston ID: HS23010683-01
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8CALCIUM7.17mg/L
E200.8MAGNESIUMNDmg/LU
E200.8POTASSIUM566mg/L
E200.8SODIUM799mg/L
E300.0CHLORIDE1600mg/L
E300.0SULFATENDmg/LU
RSK175ETHANE4930ug/L
RSK175METHANE9160ug/L
RSK175PROPANE4690ug/L
SM2320BBICARBONATE ALKALINITY as CACO3226mg/L
SM2320BCarbonate as CaCO3121mg/L
SM2320BTOTAL ALKALINITY AS CACO3348mg/L
SM2540CTOTAL DISSOLVED SOLIDS3060mg/L
SW8015TEPH DIESEL RANGE ORGANICS210mg/L
SW8015TVPH - Gasoline Range OrganicsNDmg/LU
SW8260BENZENE2600ug/L
SW8260ETHYLBENZENENDug/LU
SW8260M-+P-XYLENE2400ug/L
SW8260o-XYLENE770ug/L
SW8260TOLUENE3300ug/L
SW8260TOTAL XYLENES3100ug/L