Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#449990 Information View DocsDoc View GISGIS
Sample Site ID449990
FacilityTypeOGProj Number
CountyWELD - 123LocationNENE 35 4N65W
Elevation4771Lat/Long40.274488/-104.621984
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-44608Well Name:Centennial State G34-679
Well Status:PROperator Name:NOBLE ENERGY INC
Location:NENE  35 4N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   663016     Sample Date:  9/24/2024     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 663016    Dolan Integration Group ID: DIG-037149
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-TrimethylcyclopentaneNDAREA COUNT1ND
G02G1,1,3-TrimethylcyclopentaneNDppm10ND
G02G1,1-dimethylcyclopentaneNDAREA COUNT1ND
G02G1,1-dimethylcyclopentaneNDppm10ND
G02G1,2,3-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,3-trimethylcyclopentaneNDppm10ND
G02G1,2,4-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,4-trimethylcyclopentaneNDppm10ND
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentaneNDAREA COUNT1ND
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,3-DIMETHYLBUTANENDppm10ND
G02G2,3-dimethylpentane0.218AREA COUNT1
G02G2,3-dimethylpentane16ppm10
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-methylhexane1.175AREA COUNT1
G02G2-methylhexane87ppm10
G02G2-METHYLPENTANE1.3AREA COUNT1
G02G2-METHYLPENTANE96ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexaneNDAREA COUNT1ND
G02G3-methylhexaneNDppm10ND
G02G3-METHYLPENTANENDAREA COUNT1ND
G02G3-METHYLPENTANENDppm10ND
G02GBENZENENDAREA COUNT1ND
G02GBENZENENDppm10ND
G02GBUTANE2.545AREA COUNT1
G02GBUTANE186ppm10
G02Gcis-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gcis-1,3-dimethylcyclopentaneNDppm10ND
G02GCYCLOHEXANE1.044AREA COUNT1
G02GCYCLOHEXANE79ppm10
G02GCYCLOPENTANENDAREA COUNT1ND
G02GCYCLOPENTANENDppm10ND
G02GDecane12.653AREA COUNT1
G02GDecane942ppm10
G02GETHYLBENZENENDAREA COUNT1ND
G02GETHYLBENZENENDppm10ND
G02GethylcyclopentaneNDAREA COUNT1ND
G02GethylcyclopentaneNDppm10ND
G02GHeptane3.043AREA COUNT1
G02GHeptane225ppm10
G02GHEXANES2.269AREA COUNT1
G02GHEXANES167ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANENDAREA COUNT1ND
G02GISOBUTANENDppm10ND
G02GISOPENTANE1.637AREA COUNT1
G02GISOPENTANE117ppm10
G02Gisoprenoid C103.984AREA COUNT1
G02Gisoprenoid C10297ppm10
G02Gisoprenoid C114.837AREA COUNT1
G02Gisoprenoid C11361ppm10
G02Gisoprenoid C1323.123AREA COUNT1
G02Gisoprenoid C131727ppm10
G02Gisoprenoid C1447.245AREA COUNT1
G02Gisoprenoid C143533ppm10
G02Gisoprenoid C1581.244AREA COUNT1
G02Gisoprenoid C156081ppm10
G02Gisoprenoid C16111.949AREA COUNT1
G02Gisoprenoid C168380ppm10
G02Gisoprenoid C18122.295AREA COUNT1
G02Gisoprenoid C189163ppm10
G02Gisoprenoid C9NDAREA COUNT1ND
G02Gisoprenoid C9NDppm10ND
G02Gm-XYLENE4.758AREA COUNT1
G02Gm-XYLENE346ppm10
G02GMETHYL CYCLOHEXANE4.097AREA COUNT1
G02GMETHYL CYCLOHEXANE309ppm10
G02GMETHYLCYCLOPENTANENDAREA COUNT1ND
G02GMETHYLCYCLOPENTANENDppm10ND
G02Gn-C1129.826AREA COUNT1
G02Gn-C112224ppm10
G02Gn-C1251.12AREA COUNT1
G02Gn-C123815ppm10
G02Gn-C13110.411AREA COUNT1
G02Gn-C138248ppm10
G02Gn-C14189.744AREA COUNT1
G02Gn-C1414188ppm10
G02Gn-C15241.63AREA COUNT1
G02Gn-C1518086ppm10
G02Gn-C16253.042AREA COUNT1
G02Gn-C1618941ppm10
G02Gn-C17217.333AREA COUNT1
G02Gn-C1716284ppm10
G02Gn-C18190.229AREA COUNT1
G02Gn-C1814253ppm10
G02Gn-C19153.62AREA COUNT1
G02Gn-C1911510ppm10
G02Gn-C20148.607AREA COUNT1
G02Gn-C2011144ppm10
G02Gn-C21107.117AREA COUNT1
G02Gn-C218036ppm10
G02Gn-C2283.893AREA COUNT1
G02Gn-C226295ppm10
G02Gn-C2356.739AREA COUNT1
G02Gn-C234259ppm10
G02Gn-C2441.261AREA COUNT1
G02Gn-C243098ppm10
G02Gn-C2525.322AREA COUNT1
G02Gn-C251902ppm10
G02Gn-C2615.339AREA COUNT1
G02Gn-C261152ppm10
G02Gn-C277.166AREA COUNT1
G02Gn-C27538ppm10
G02Gn-C283.902AREA COUNT1
G02Gn-C28293ppm10
G02Gn-C291.282AREA COUNT1
G02Gn-C2996ppm10
G02Gn-C300.932AREA COUNT1
G02Gn-C3070ppm10
G02Gn-C31NDAREA COUNT1ND
G02Gn-C31NDppm10ND
G02Gn-c32NDAREA COUNT1ND
G02Gn-c32NDppm10ND
G02Gn-C33NDAREA COUNT1ND
G02Gn-C33NDppm10ND
G02Gn-C34NDAREA COUNT1ND
G02Gn-C34NDppm10ND
G02Gn-C35NDAREA COUNT1ND
G02Gn-C35NDppm10ND
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane3.948AREA COUNT1
G02Gn-octane293ppm10
G02GNormal Alkane C97.103AREA COUNT1
G02GNormal Alkane C9528ppm10
G02Go-XYLENE2.125AREA COUNT1
G02Go-XYLENE157ppm10
G02Gp-XYLENE1.729AREA COUNT1
G02Gp-XYLENE131ppm10
G02GPENTANE2.257AREA COUNT1
G02GPENTANE166ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane141.639AREA COUNT1
G02Gphytane10623ppm10
G02Gpristane127.29AREA COUNT1
G02Gpristane9538ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE3.518AREA COUNT1
G02GTOLUENE248ppm10
G02Gtrans-1,2-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,2-dimethylcyclopentaneNDppm10ND
G02Gtrans-1,3-dimethylcyclopentaneNDAREA COUNT1ND
G02Gtrans-1,3-dimethylcyclopentaneNDppm10ND

 Sample ID:   618517     Sample Date:  7/16/2020     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Zedi US inc

Sample Results for Sample # 618517    Zedi US inc ID: 20072208-02
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM9500mg/L50
E200.7IRON0.9mg/L0.5
E200.7MAGNESIUMNDmg/L0.5<
E200.7POTASSIUM320mg/L50
E200.7SILICA (SiO2)12.2mg/L0.05
E200.7SODIUM1100mg/L50
E300.0BROMIDENDmg/L10<
E300.0CHLORIDE20500mg/L1000
E300.0FLUORIDENDmg/L2<
E300.0NITRATE24.5mg/L10
E300.0NITRATE AS N5.5mg/L0.22
E300.0NITRITE AS NNDmg/L0.03<
E300.0SULFATE1072mg/L100
SM 2540CTOTAL DISSOLVED SOLIDS33260mg/L5
SM2320BBICARBONATE ALKALINITY as CACO3350mg/L2
SM2320BCarbonate as CaCO3400mg/L2
SM2320BHYDROXIDE ALKALINITY AS CACO3NDmg/L2<
SW8015C10-C28 Diesel Range Organics9335mg/L50
SW8260BENZENENDug/L500<
SW8260ETHYLBENZENENDug/L500<
SW8260M-+P-XYLENE2220ug/L1000
SW8260TOLUENE1150ug/L500

 Sample ID:   618518     Sample Date:  7/16/2020     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 618518    Dolan Integration Group ID: DIG-023333
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPETHANE0.26mg/L0.002
SOPMETHANE4.56mg/L0.002
SOPPROPANE0.27mg/L0.002

 Sample ID:   616040     Sample Date:  2/18/2020     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 616040    Dolan Integration Group ID: DIG-021936
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPETHANE0.45mg/L0.002
SOPMETHANE6.87mg/L0.002
SOPPROPANE0.56mg/L0.002

 Sample ID:   616039     Sample Date:  2/18/2020     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 616039    Dolan Integration Group ID: DIG-021929
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1065BTU/cuft
SOPBUTANE0.89MOL %0.005
SOPC6+ (hexanes +)0.14MOL %0.005
SOPCARBON DIOXIDE0.26MOL %0.005
SOPDELTA 13C C1-42.4per mil
SOPDELTA 13C C2-27.6per mil
SOPDELTA 13C C3-25.3per mil
SOPDELTA 13C iC4-27.9per mil
SOPDELTA 13C nC4-25.2per mil
SOPDELTA D C1-224per mil
SOPETHANE8.63MOL %0.005
SOPETHENE0.02MOL %0.005
SOPHelium0.02MOL %0.005
SOPHYDROGEN0.47MOL %0.005
SOPISOBUTANE0.49MOL %0.005
SOPISOPENTANE0.21MOL %0.005
SOPMETHANE74.82MOL %0.005
SOPNITROGEN (N2)8.41MOL %0.005
SOPOXYGEN + ARGON2.16MOL %0.005
SOPPENTANE0.2MOL %0.005
SOPPROPANE3.29MOL %0.005
SOPSPECIFIC GRAVITY0.709No Unit