Sample ID: 613753 Sample Date: 12/10/2019 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 613753 ISOTECH ID: 744873 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.496 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 567 | BTU | | | | SOP | BUTANE | 0.356 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0165 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.65 | ‰ | | | | SOP | DELTA 13C C2 | -32.14 | ‰ | | | | SOP | DELTA 13C C3 | -28.12 | ‰ | | | | SOP | DELTA 13C iC4 | -31.07 | ‰ | | | | SOP | DELTA 13C nC4 | -27.09 | ‰ | | | | SOP | DELTA D C1 | -237.8 | ‰ | | | | SOP | ETHANE | 6.56 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0003 | MOL % | 0.0001 | | | SOP | Helium | 0.014 | MOL % | 0.005 | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.159 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.052 | MOL % | 0.0001 | | | SOP | METHANE | 37.23 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 42.24 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 10.78 | MOL % | 0.01 | | | SOP | PENTANE | 0.0423 | MOL % | 0.0001 | | | SOP | PROPANE | 2.05 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0001 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.853 | RATIO_AIR | | |
Sample ID: 613757 Sample Date: 12/10/2019 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 613757 ISOTECH ID: 744967 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1234 | BTU | | | | SOP | BUTANE | 1.57 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0186 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.4 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.43 | ‰ | | | | SOP | DELTA 13C C2 | -31.98 | ‰ | | | | SOP | DELTA 13C C3 | -28.24 | ‰ | | | | SOP | DELTA 13C CO2 | 3.17 | ‰ | | | | SOP | DELTA 13C iC4 | -30.98 | ‰ | | | | SOP | Delta 13C iC5 | -27.85 | ‰ | | | | SOP | DELTA 13C nC4 | -27.43 | ‰ | | | | SOP | Delta 13C nC5 | -26.72 | ‰ | | | | SOP | DELTA D C1 | -241.2 | ‰ | | | | SOP | ETHANE | 13.44 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0011 | MOL % | 0.0001 | | | SOP | Helium | 0.0078 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0281 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.661 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.277 | MOL % | 0.0001 | | | SOP | METHANE | 75.94 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.34 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.011 | MOL % | 0.01 | | | SOP | PENTANE | 0.249 | MOL % | 0.0001 | | | SOP | PROPANE | 5.06 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.736 | RATIO_AIR | | |
Sample ID: 613754 Sample Date: 12/10/2019 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 613754 ISOTECH ID: 744873 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 1.3 | mg/L | 0.01 | | | SOP | ETHANE | 14 | mg/L | 0.0002 | | | SOP | METHANE | 38 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 67 | mg/L | 0.02 | | | SOP | PROPANE | 5.9 | mg/L | 0.0003 | |
Sample ID: 613755 Sample Date: 12/10/2019 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 613755 Accutest ID: DA22596-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 0.299 | mg/L | 0.05 | | | E200.7 | CALCIUM | 61.1 | mg/L | 0.4 | | | E200.7 | IRON | 0.139 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | | E200.7 | POTASSIUM | 188 | mg/L | 1 | | | E200.7 | SODIUM | 559 | mg/L | 4 | | | E200.7 | STRONTIUM | 6.69 | mg/L | 0.05 | | | E200.8 | BARIUM | 0.103 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.0024 | mg/L | 0.0008 | | | E300.0 | BROMIDE | 0.79 | mg/L | 0.05 | | | E300.0 | CHLORIDE | 183 | mg/L | 5 | | | E300.0 | FLUORIDE | 1.6 | mg/L | 1 | | | E300.0 | NITRATE | 13.5 | mg/L | 1 | | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | | E300.0 | SULFATE | 116 | mg/L | 5 | | | FIELD | pH, FIELD | 13.7 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 5820 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 7.7 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 2.4 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 200 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 1300 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 930 | mg/L | 29 | | | SW8015 | TVPH - Gasoline Range Organics | 3.1 | mg/L | 0.05 | | | SW8260 | BENZENE | 45.6 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 12.2 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 111 | ug/L | 1 | | | SW8260 | o-XYLENE | 66.7 | ug/L | 1 | | | SW8260 | TOLUENE | 144 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 177 | ug/L | 1 | |
Sample ID: 613756 Sample Date: 12/10/2019 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 613756 Accutest ID: DA22597-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 630962 Sample Date: 10/12/2021 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 630962 ISOTECH ID: 806932 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.0171 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1223 | BTU | | | | SOP | BUTANE | 1.49 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0308 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.38 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.8 | ‰ | | | | SOP | DELTA 13C C2 | -32.3 | ‰ | | | | SOP | DELTA 13C C3 | -28.7 | ‰ | | | | SOP | DELTA 13C CO2 | 3.6 | ‰ | | | | SOP | DELTA 13C iC4 | -31.2 | ‰ | | | | SOP | Delta 13C iC5 | -28.2 | ‰ | | | | SOP | DELTA 13C nC4 | -27.8 | ‰ | | | | SOP | Delta 13C nC5 | -26.9 | ‰ | | | | SOP | DELTA D C1 | -242 | ‰ | | | | SOP | ETHANE | 13.45 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0014 | MOL % | 0.0001 | | | SOP | Helium | 0.0078 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0883 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.708 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.268 | MOL % | 0.0001 | | | SOP | METHANE | 73.87 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 1.54 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.39 | MOL % | 0.01 | | | SOP | PENTANE | 0.234 | MOL % | 0.0001 | | | SOP | PROPANE | 5.52 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.746 | RATIO_AIR | | |
Sample ID: 630958 Sample Date: 10/12/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 630958 ISOTECH ID: 806521 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.376 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 892 | BTU | | | | SOP | BUTANE | 0.622 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.148 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.99 | ‰ | | | | SOP | DELTA 13C C2 | -31.94 | ‰ | | | | SOP | DELTA 13C C3 | -28.04 | ‰ | | | | SOP | DELTA 13C iC4 | -31.3 | ‰ | | | | SOP | Delta 13C iC5 | -28.4 | ‰ | | | | SOP | DELTA 13C nC4 | -27.2 | ‰ | | | | SOP | Delta 13C nC5 | -27 | ‰ | | | | SOP | DELTA D C1 | -234.7 | ‰ | | | | SOP | ETHANE | 12.1 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0009 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.77 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.24 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0904 | MOL % | 0.0001 | | | SOP | METHANE | 53.66 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 21.53 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 7.59 | MOL % | 0.01 | | | SOP | PENTANE | 0.0826 | MOL % | 0.0001 | | | SOP | PROPANE | 3.56 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0004 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.8 | RATIO_AIR | | |
Sample ID: 630959 Sample Date: 10/12/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 630959 ISOTECH ID: 806521 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.25 | mg/L | 0.01 | | | SOP | ETHANE | 6.5 | mg/L | 0.0002 | | | SOP | METHANE | 14 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 8.9 | mg/L | 0.02 | | | SOP | PROPANE | 2.7 | mg/L | 0.0003 | |
Sample ID: 630960 Sample Date: 10/12/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 630960 Accutest ID: DA38248-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.8 | BARIUM | 0.148 | mg/L | 0.004 | | | E200.8 | BORON | 0.3 | mg/L | 0.16 | | | E200.8 | CALCIUM | 57.7 | mg/L | 0.8 | | | E200.8 | IRON | 0.644 | mg/L | 0.04 | | | E200.8 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.8 | MANGANESE | 0.0092 | mg/L | 0.002 | | | E200.8 | POTASSIUM | 153 | mg/L | 5 | | | E200.8 | SELENIUM | 0.0015 | mg/L | 0.0008 | | | E200.8 | SODIUM | 707 | mg/L | 13 | | | E200.8 | STRONTIUM | 6.97 | mg/L | 0.5 | | | E300.0 | BROMIDE | 0.69 | mg/L | 0.5 | | | E300.0 | CHLORIDE | 142 | mg/L | 5 | | | E300.0 | FLUORIDE | 1.6 | mg/L | 1 | | | E300.0 | NITRATE | 14.2 | mg/L | 0.5 | | | E300.0 | NITRATE/NITRITE AS N | 14.2 | mg/L | 0.54 | | | E300.0 | NITRITE | ND | mg/L | 0.04 | U | | E300.0 | SULFATE | 119 | mg/L | 5 | | | FIELD | pH, FIELD | 10.7 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 6340 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 18.3 | degrees C | | | | SW8015 | TVPH - Gasoline Range Organics | 3.58 | mg/L | 0.25 | | | SW8260 | BENZENE | 67.2 | ug/L | 5 | | | SW8260 | ETHYLBENZENE | 38.3 | ug/L | 5 | | | SW8260 | M-+P-XYLENE | 506 | ug/L | 5 | | | SW8260 | o-XYLENE | 169 | ug/L | 5 | | | SW8260 | TOLUENE | 308 | ug/L | 5 | | | SW8260 | TOTAL XYLENES | 675 | ug/L | 5 | |
Sample ID: 630961 Sample Date: 10/12/2021 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 630961 Accutest ID: DA38265-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 654745 Sample Date: 10/02/2023 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 654745 ISOTECH ID: 893581 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1239 | BTU | | | | SOP | BUTANE | 1.58 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0074 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.32 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.56 | ‰ | | | | SOP | DELTA 13C C2 | -32.06 | ‰ | | | | SOP | DELTA 13C C3 | -28.47 | ‰ | | | | SOP | DELTA 13C CO2 | 3.06 | ‰ | | | | SOP | DELTA 13C iC4 | -31.05 | ‰ | | | | SOP | Delta 13C iC5 | -27.73 | ‰ | | | | SOP | DELTA 13C nC4 | -27.48 | ‰ | | | | SOP | Delta 13C nC5 | -26.56 | ‰ | | | | SOP | DELTA D C1 | -241.3 | ‰ | | | | SOP | ETHANE | 13.25 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0005 | MOL % | 0.0001 | | | SOP | Helium | 0.0068 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0429 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.738 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.213 | MOL % | 0.0001 | | | SOP | METHANE | 75.6 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.37 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.034 | MOL % | 0.01 | | | SOP | PENTANE | 0.15 | MOL % | 0.0001 | | | SOP | PROPANE | 5.69 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.738 | RATIO_AIR | | |
Sample ID: 654741 Sample Date: 10/02/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 654741 ISOTECH ID: 892440 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.426 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 868 | BTU | | | | SOP | BUTANE | 0.567 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0508 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -46.78 | ‰ | | | | SOP | DELTA 13C C2 | -31.9 | ‰ | | | | SOP | DELTA 13C C3 | -27.9 | ‰ | | | | SOP | DELTA 13C iC4 | -30.9 | ‰ | | | | SOP | Delta 13C iC5 | -28.2 | ‰ | | | | SOP | DELTA 13C nC4 | -27.3 | ‰ | | | | SOP | Delta 13C nC5 | -26.4 | ‰ | | | | SOP | DELTA D C1 | -234.2 | ‰ | | | | SOP | ETHANE | 11.98 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0008 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.76 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.223 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0697 | MOL % | 0.0001 | | | SOP | METHANE | 52.64 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 22.86 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 7.66 | MOL % | 0.01 | | | SOP | PENTANE | 0.0609 | MOL % | 0.0001 | | | SOP | PROPANE | 3.46 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0004 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.801 | RATIO_AIR | | |
Sample ID: 654742 Sample Date: 10/02/2023 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 654742 ISOTECH ID: 892440 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.29 | mg/L | 0.01 | | | SOP | ETHANE | 6.5 | mg/L | 0.0002 | | | SOP | METHANE | 14 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 9.6 | mg/L | 0.02 | | | SOP | PROPANE | 2.6 | mg/L | 0.0003 | |
Sample ID: 654743 Sample Date: 10/02/2023 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 654743 Accutest ID: DA59070-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | FIELD | pH, FIELD | 12.5 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 5720 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 15.4 | degrees C | | | | SW8015 | TVPH - Gasoline Range Organics | 2.34 | mg/L | 0.25 | | | SW8260 | BENZENE | 6.6 | ug/L | 1 | | | SW8260 | ETHYLBENZENE | 1.6 | ug/L | 1 | | | SW8260 | M-+P-XYLENE | 15.2 | ug/L | 1 | | | SW8260 | o-XYLENE | 8.7 | ug/L | 1 | | | SW8260 | TOLUENE | 19.9 | ug/L | 1 | | | SW8260 | TOTAL XYLENES | 23.9 | ug/L | 1 | |
Sample ID: 654744 Sample Date: 10/02/2023 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 654744 Accutest ID: DA59071-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|