Sample ID: 634466 Sample Date: 12/16/2021 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 634466 Accutest ID: DA40163-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 634467 Sample Date: 12/16/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 634467 Accutest ID: DA40162-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2200 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0396 | mg/L | 0.004 | | E200.8 | BORON | ND | mg/L | 0.08 | U | E200.8 | CALCIUM | 2.62 | mg/L | 0.8 | | E200.8 | IRON | ND | mg/L | 0.04 | U | E200.8 | MAGNESIUM | 0.336 | mg/L | 0.2 | | E200.8 | MANGANESE | 0.0054 | mg/L | 0.002 | | E200.8 | POTASSIUM | 0.957 | mg/L | 0.4 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E200.8 | SODIUM | 151 | mg/L | 7.5 | | E200.8 | STRONTIUM | 0.0562 | mg/L | 0.04 | | E300.0 | BROMIDE | ND | mg/L | 0.05 | U | E300.0 | CHLORIDE | 3.4 | mg/L | 0.5 | | E300.0 | FLUORIDE | 3.8 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.01 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.014 | U | E300.0 | NITRITE | ND | mg/L | 0.004 | U | E300.0 | SULFATE | 0.79 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.074 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.18 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | 104 | mV | | | FIELD | pH, FIELD | 8.4 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 675 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 12.91 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | ND | mg/L | 0.016 | U | RSK175 | METHANE | 0.695 | mg/L | 0.008 | | RSK175 | PROPANE | ND | mg/L | 0.022 | U | SM1030 | CATION - ANION BALANCE | 4.5 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 331 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 22.5 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 354 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 673 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 417 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.81 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 622471 Sample Date: 11/16/2020 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 622471 Accutest ID: DA30582-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 622472 Sample Date: 11/16/2020 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 622472 Accutest ID: DA30581-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.7 | BORON | 0.0663 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.54 | mg/L | 0.4 | | E200.7 | IRON | ND | mg/L | 0.01 | U | E200.7 | MAGNESIUM | 0.333 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0075 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.27 | mg/L | 1 | | E200.7 | SODIUM | 154 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.052 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0342 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.062 | mg/L | 0.05 | | E300.0 | CHLORIDE | 3 | mg/L | 0.5 | | E300.0 | FLUORIDE | 3.8 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.01 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.014 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.004 | U | E300.0 | SULFATE | 0.54 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.077 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.02 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | 62.6 | mV | | | FIELD | pH, FIELD | 8.4 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 621 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 13.9 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 0.0013 | mg/L | 0.0016 | J | RSK175 | METHANE | 0.391 | mg/L | 0.0008 | | RSK175 | PROPANE | ND | mg/L | 0.0022 | U | SM1030 | CATION - ANION BALANCE | 2.2 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 285 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 30 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 315 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 542 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 375 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.62 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 612198 Sample Date: 10/21/2019 Matrix: GAS Collection Point: Irr Type: GW Lab: ISOTECHSample Results for Sample # 612198 ISOTECH ID: 739956 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 1.68 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 85 | BTU | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | SOP | CARBON DIOXIDE | 0.54 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -77.47 | ‰ | | | SOP | DELTA D C1 | -272.8 | ‰ | | | SOP | ETHANE | 0.0098 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.77 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | SOP | METHANE | 8.33 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 86.16 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 3.28 | MOL % | 0.01 | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | SOP | PROPANE | ND | MOL % | 0.0001 | ND | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.947 | RATIO_AIR | | |
Sample ID: 612199 Sample Date: 10/21/2019 Matrix: WATER Collection Point: Irr Type: GW Lab: ISOTECHSample Results for Sample # 612199 ISOTECH ID: 739956 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ETHANE | 0.0036 | mg/L | 0.0002 | | SOP | METHANE | 1.4 | mg/L | 0.0001 | | SOP | PROPANE | ND | mg/L | 0.0002 | ND |
Sample ID: 612197 Sample Date: 10/21/2019 Matrix: WATER Collection Point: Irr Type: GW Lab: --Sample Results for Sample # 612197 -- ID: L1152347-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | | U | BART | BACTERIA, SULFATE REDUCING | 20 | cfu/ml | | | E353.2 | NITRATE/NITRITE | ND | mg/L | 0.1 | U | E365.4 | PHOSPHORUS | ND | mg/L | 0.1 | U | RSK-175 | ETHANE | ND | mg/L | 0.013 | U | RSK-175 | METHANE | 1.81 | mg/L | 0.01 | | RSK-175 | PROPANE | ND | mg/L | 0.02 | U | SM2320B | BICARBONATE ALKALINITY as CACO3 | 335 | mg/L | 20 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | SM2320B | TOTAL ALKALINITY AS CACO3 | 347 | mg/L | 20 | | SM2540C | TOTAL DISSOLVED SOLIDS | 378 | mg/L | 10 | | SW6010 | BARIUM | 0.0375 | mg/L | 0.005 | | SW6010 | BORON | ND | mg/L | 0.2 | U | SW6010 | CALCIUM | 2.71 | mg/L | 1 | | SW6010 | IRON | ND | mg/L | 0.1 | U | SW6010 | MAGNESIUM | ND | mg/L | 1 | U | SW6010 | MANGANESE | ND | mg/L | 0.01 | U | SW6010 | POTASSIUM | 1.2 | mg/L | 1 | B | SW6010 | SODIUM | 163 | mg/L | 1 | | SW6010 | STRONTIUM | 0.0555 | mg/L | 0.01 | | SW6020 | SELENIUM | ND | mg/L | 0.002 | U | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.1 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.1 | U | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.002 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U | SW9040 | PH, LAB | 8.67 | SU | | T8 | SW9050 | SPECIFIC CONDUCTIVITY | 660 | UMHOS/CM | 10 | | SW9056 | BROMIDE | ND | mg/L | 1 | U | SW9056 | CHLORIDE | 2.8 | mg/L | 1 | | SW9056 | FLUORIDE | 3.76 | mg/L | 0.1 | | SW9056 | NITRATE | ND | mg/L | 0.1 | U | SW9056 | Nitrite as NO2 | ND | mg/L | 0.1 | U | SW9056 | SULFATE | ND | mg/L | 5 | U |
Sample ID: 612200 Sample Date: 10/21/2019 Matrix: WATER Collection Point: TB Type: TB Lab: --Sample Results for Sample # 612200 -- ID: L1152354-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.002 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U |
Sample ID: 566439 Sample Date: 3/22/2018 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 566439 ISOTECH ID: 658620 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 1.65 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 77 | BTU | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | SOP | CARBON DIOXIDE | 0.74 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -74.13 | ‰ | | | SOP | DELTA D C1 | -252.6 | ‰ | | | SOP | ETHANE | 0.0098 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.82 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | SOP | METHANE | 7.62 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 85.46 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 4.52 | MOL % | 0.01 | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | SOP | PROPANE | ND | MOL % | 0.0001 | ND | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.953 | RATIO_AIR | | |
Sample ID: 566436 Sample Date: 3/22/2018 Matrix: WATER Collection Point: TB Type: TB Lab: --Sample Results for Sample # 566436 -- ID: L980198-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.002 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U |
Sample ID: 566434 Sample Date: 3/22/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ESCSample Results for Sample # 566434 ESC ID: L980196-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | | | BART | BACTERIA, SLIME FORMING | 13000 | cfu/ml | | | BART | BACTERIA, SULFATE REDUCING | 20 | cfu/ml | | | E353.2 | NITRATE/NITRITE | ND | mg/L | 0.1 | U | E365.4 | PHOSPHORUS | ND | mg/L | 0.1 | U | RSK-175 | ETHANE | ND | mg/L | 0.013 | U | RSK-175 | ETHENE | ND | mg/L | 0.013 | U | RSK-175 | METHANE | 1.88 | mg/L | 0.01 | | RSK-175 | PROPANE | ND | mg/L | 0.02 | U | SM2320B | BICARBONATE ALKALINITY as CACO3 | 288 | mg/L | 20 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | SM2320B | TOTAL ALKALINITY AS CACO3 | 300 | mg/L | 20 | | SM2540C | TOTAL DISSOLVED SOLIDS | 398 | mg/L | 10 | | SW6010 | BARIUM | 0.037 | mg/L | 0.005 | | SW6010 | BORON | ND | mg/L | 0.2 | U | SW6010 | CALCIUM | 2.7 | mg/L | 1 | | SW6010 | IRON | ND | mg/L | 0.1 | U | SW6010 | MAGNESIUM | ND | mg/L | 1 | U | SW6010 | MANGANESE | ND | mg/L | 0.01 | U | SW6010 | POTASSIUM | 1.19 | mg/L | 1 | B | SW6010 | SODIUM | 171 | mg/L | 1 | | SW6010 | STRONTIUM | 0.0557 | mg/L | 0.01 | | SW6020 | SELENIUM | ND | mg/L | 0.002 | U | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.1 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.1 | U | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.002 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U | SW9040 | PH, LAB | 8.63 | SU | | T8 | SW9050 | SPECIFIC CONDUCTIVITY | 655 | UMHOS/CM | 10 | | SW9056 | BROMIDE | ND | mg/L | 1 | U | SW9056 | CHLORIDE | 3 | mg/L | 1 | J3 | SW9056 | FLUORIDE | 3.73 | mg/L | 0.1 | J3 | SW9056 | NITRATE | ND | mg/L | 0.1 | U | SW9056 | Nitrite as NO2 | ND | mg/L | 0.1 | U | SW9056 | SULFATE | ND | mg/L | 5 | U |
Sample ID: 566440 Sample Date: 3/22/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 566440 ISOTECH ID: 658620 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ETHANE | 0.0032 | mg/L | 0.0002 | | SOP | METHANE | 1.2 | mg/L | 0.0002 | | SOP | PROPANE | ND | mg/L | 0.0003 | ND |
|
|