Sample ID: 612131 Sample Date: 10/16/2019 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 612131 ISOTECH ID: 739255 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.658 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 653 | BTU | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | SOP | CARBON DIOXIDE | 0.43 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -72.91 | ‰ | | | SOP | DELTA D C1 | -275.3 | ‰ | | | SOP | ETHANE | 0.0782 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.62 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | SOP | METHANE | 64.36 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 33.24 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.23 | MOL % | 0.01 | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | SOP | PROPANE | ND | MOL % | 0.0001 | ND | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.708 | RATIO_AIR | | |
Sample ID: 612132 Sample Date: 10/16/2019 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 612132 ISOTECH ID: 739255 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ETHANE | 0.057 | mg/L | 0.0002 | | SOP | METHANE | 23 | mg/L | 0.0002 | | SOP | PROPANE | ND | mg/L | 0.0003 | ND |
Sample ID: 612196 Sample Date: 10/16/2019 Matrix: WATER Collection Point: TB Type: TB Lab: --Sample Results for Sample # 612196 -- ID: L1151128-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.002 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U |
Sample ID: 605001 Sample Date: 9/12/2018 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 605001 ISOTECH ID: 693515 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 1.18 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 72 | BTU | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | SOP | CARBON DIOXIDE | 0.52 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -66.08 | ‰ | | | SOP | DELTA D C1 | -261.7 | ‰ | | | SOP | ETHANE | 0.0176 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.76 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | SOP | METHANE | 7.05 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 65.82 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 25.41 | MOL % | 0.01 | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | SOP | PROPANE | ND | MOL % | 0.0001 | ND | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.981 | RATIO_AIR | | |
Sample ID: 605004 Sample Date: 9/12/2018 Matrix: WATER Collection Point: TB Type: TB Lab: Summit Scientific Sample Results for Sample # 605004 Summit Scientific ID: L1028490-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U |
Sample ID: 605003 Sample Date: 9/12/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: Summit Scientific Sample Results for Sample # 605003 Summit Scientific ID: L1025240-01 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | | cfu/ml | | | BART | BACTERIA, SLIME FORMING | 100 | cfu/ml | | | BART | BACTERIA, SULFATE REDUCING | | cfu/ml | | | E353.2 | NITRATE/NITRITE | ND | mg/L | 0.1 | U | E365.4 | PHOSPHORUS | 3.01 | mg/L | 0.1 | | RSK-175 | ETHANE | 0.0281 | mg/L | 0.013 | | RSK-175 | ETHENE | ND | mg/L | 0.013 | U | RSK-175 | METHANE | 11.2 | mg/L | 0.1 | | RSK-175 | PROPANE | ND | mg/L | 0.02 | U | SM2320B | BICARBONATE ALKALINITY as CACO3 | 467 | mg/L | 20 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 20.3 | mg/L | 20 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 487 | mg/L | 20 | | SM2540C | TOTAL DISSOLVED SOLIDS | 665 | mg/L | 13.3 | Q | SW6010 | BARIUM | 0.0549 | mg/L | 0.005 | | SW6010 | BORON | 0.314 | mg/L | 0.2 | | SW6010 | CALCIUM | 1.79 | mg/L | 1 | | SW6010 | IRON | 1.43 | mg/L | 0.1 | | SW6010 | MAGNESIUM | ND | mg/L | 1 | U | SW6010 | MANGANESE | 0.0155 | mg/L | 0.01 | | SW6010 | POTASSIUM | 1.85 | mg/L | 1 | B | SW6010 | SODIUM | 241 | mg/L | 1 | | SW6010 | STRONTIUM | 0.0648 | mg/L | 0.01 | | SW6020 | SELENIUM | ND | mg/L | 0.002 | U | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.1 | U | SW8015 | TVPH - Gasoline Range Organics | 1.84 | mg/L | 0.1 | | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.001 | U | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U | SW9040 | PH, LAB | 7.67 | SU | | T8 | SW9050 | SPECIFIC CONDUCTIVITY | 1110 | UMHOS/CM | 10 | | SW9056 | BROMIDE | ND | mg/L | 1 | U | SW9056 | CHLORIDE | 59.7 | mg/L | 1 | | SW9056 | FLUORIDE | 2.33 | mg/L | 0.1 | | SW9056 | NITRATE | ND | mg/L | 0.1 | U | SW9056 | Nitrite as NO2 | ND | mg/L | 0.1 | U | SW9056 | SULFATE | ND | mg/L | 5 | U |
Sample ID: 605002 Sample Date: 9/12/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 605002 ISOTECH ID: 693515 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ETHANE | 0.0084 | mg/L | 0.0002 | | SOP | METHANE | 1.7 | mg/L | 0.0002 | | SOP | PROPANE | ND | mg/L | 0.0003 | ND |
Sample ID: 601139 Sample Date: 7/10/2018 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 601139 ISOTECH ID: 672187 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.693 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 619 | BTU | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | SOP | C6+ (hexanes +) | ND | MOL % | 0.0001 | ND | SOP | CARBON DIOXIDE | 0.34 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -73.08 | ‰ | | | SOP | DELTA 13C C2 | -48.2 | ‰ | | | SOP | DELTA D C1 | -270.1 | ‰ | | | SOP | ETHANE | 0.0654 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.65 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | SOP | METHANE | 61.01 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 35.2 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 2.69 | MOL % | 0.01 | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | SOP | PROPANE | ND | MOL % | 0.0001 | ND | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.724 | RATIO_AIR | | |
Sample ID: 601140 Sample Date: 7/10/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 601140 ISOTECH ID: 672187 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.6 | mg/L | 0.01 | | SOP | ETHANE | 0.047 | mg/L | 0.0002 | | SOP | METHANE | 21 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 19 | mg/L | 0.02 | | SOP | PROPANE | ND | mg/L | 0.0003 | ND |
Sample ID: 601137 Sample Date: 7/10/2018 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 601137 Accutest ID: DA7000-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 601138 Sample Date: 7/10/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 601138 Accutest ID: DA6999-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 2500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 6000 | cfu/ml | 200 | | E200.7 | BORON | 0.315 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.51 | mg/L | 0.4 | | E200.7 | IRON | 0.0282 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.438 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0057 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.88 | mg/L | 1 | | E200.7 | SODIUM | 252 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0615 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0295 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.58 | mg/L | 0.1 | | E300.0 | CHLORIDE | 56.3 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2.3 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | ND | mg/L | 1 | U | E365.1 | PHOSPHORUS | 0.11 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.04 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1060 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 22.93 | degrees C | | | FIELD | TURBIDITY | 42.9 | NTU | | | RSK175 | ETHANE | 0.0149 | mg/L | 0.0016 | | RSK175 | METHANE | 5.4 | mg/L | 0.016 | | RSK175 | PROPANE | ND | mg/L | 0.0022 | U | SM1030 | CATION - ANION BALANCE | 0.67 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 452 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 31.5 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 484 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1040 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 659 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.78 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|