Sample ID: 565759 Sample Date: 11/15/2017 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECH| Sample Results for Sample # 565759 ISOTECH ID: 655671 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 1.04 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 331 | BTU | | | | SOP | BUTANE | ND | MOL % | 0.0001 | ND | | SOP | C6+ (hexanes +) | 0.0026 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.24 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -80.52 | ‰ | | | | SOP | DELTA D C1 | -295.4 | ‰ | | | | SOP | ETHANE | 0.0191 | MOL % | 0.0001 | | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | | SOP | HELIUM DILUTION FACTOR | 0.73 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | ISOBUTANE | ND | MOL % | 0.0001 | ND | | SOP | ISOPENTANE | ND | MOL % | 0.0001 | ND | | SOP | METHANE | 32.68 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 59.17 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 6.85 | MOL % | 0.01 | | | SOP | PENTANE | ND | MOL % | 0.0001 | ND | | SOP | PROPANE | ND | MOL % | 0.0001 | ND | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.847 | RATIO_AIR | | |
Sample ID: 565760 Sample Date: 11/15/2017 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECH| Sample Results for Sample # 565760 ISOTECH ID: 655671 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ETHANE | 0.008 | mg/L | 0.0002 | | | SOP | METHANE | 6.5 | mg/L | 0.0001 | | | SOP | PROPANE | ND | mg/L | 0.0002 | ND |
Sample ID: 565754 Sample Date: 11/15/2017 Matrix: WATER Collection Point: Dom Type: Dom Lab: ALS Lab Group (formerly Paragon)| Sample Results for Sample # 565754 ALS Lab Group (formerly Paragon) ID: 1711326-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | 724R12 | GROSS ALPHA | ND | pCi/L | 1.49 | U | | BART | BACTERIA, IRON RELATED | 1 | NU | 1 | | | BART | BACTERIA, SLIME FORMING | ND | NU | 1 | U | | BART | BACTERIA, SULFATE REDUCING | ND | NU | 1 | U | | E300.0 | BROMIDE | 0.92 | mg/L | 0.2 | | | E300.0 | CHLORIDE | 8.5 | mg/L | 0.2 | | | E300.0 | FLUORIDE | 1.3 | mg/L | 0.1 | | | E300.0 | NITRATE AS N | ND | mg/L | 0.2 | U | | E300.0 | NITRITE AS N | ND | mg/L | 0.1 | U | | E300.0 | SULFATE | 2.2 | mg/L | 1 | | | E365.2 | PHOSPHORUS | ND | mg/L | 0.05 | U | | RSK175 | ETHANE | 8 | ug/L | 2 | | | RSK175 | METHANE | 3900 | ug/L | 1 | | | RSK175 | PROPANE | ND | ug/L | 1 | U | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 180 | mg/L | 20 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 180 | mg/L | 20 | | | SM2510B | SPECIFIC CONDUCTIVITY | 353 | UMHOS/CM | 1 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 220 | mg/L | 20 | | | SM4500-H+ B | PH, LAB | 8.3 | SU | 0.1 | | | SW6020 | ARSENIC | ND | mg/L | 0.002 | U | | SW6020 | BARIUM | 0.046 | mg/L | 0.005 | | | SW6020 | BORON | ND | mg/L | 0.15 | U | | SW6020 | CADMIUM | ND | mg/L | 0.002 | U | | SW6020 | CALCIUM | 7.3 | mg/L | 1 | | | SW6020 | CHROMIUM | ND | mg/L | 0.01 | U | | SW6020 | IRON | ND | mg/L | 0.1 | U | | SW6020 | LEAD | 0.0021 | mg/L | 0.002 | | | SW6020 | MAGNESIUM | 0.56 | mg/L | 0.1 | | | SW6020 | MANGANESE | 0.021 | mg/L | 0.005 | | | SW6020 | POTASSIUM | 1.3 | mg/L | 1 | | | SW6020 | SELENIUM | ND | mg/L | 0.01 | U | | SW6020 | SILVER | ND | mg/L | 0.0005 | U | | SW6020 | SODIUM | 87 | mg/L | 1 | | | SW6020 | STRONTIUM | 0.14 | mg/L | 0.005 | | | SW6020 | URANIUM | 0.00011 | mg/L | 0.0001 | | | SW7470 | MERCURY | ND | mg/L | 0.0002 | U | | SW8015 | TEPH DIESEL RANGE ORGANICS | 0.23 | mg/L | 0.6 | | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U | | SW8260 | TVPH - Gasoline Range Organics | ND | ug/L | 100 | U |
Sample ID: 642973 Sample Date: 08/29/2022 Matrix: GAS Collection Point: Dom Type: GW Lab: Dolan Integration Group| Sample Results for Sample # 642973 Dolan Integration Group ID: DIG-029129 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | BUTANE | ND | MOL % | 0.005 | ND | | SOP | C6+ (hexanes +) | ND | MOL % | 0.005 | ND | | SOP | CARBON DIOXIDE | 0.02 | MOL % | 0.005 | | | SOP | DELTA 13C C1 | -76.9 | per mil | | | | SOP | DELTA D C1 | -298 | per mil | | | | SOP | ETHANE | 0.02 | MOL % | 0.005 | | | SOP | ETHENE | ND | MOL % | 0.005 | ND | | SOP | Helium | ND | MOL % | 0.005 | ND | | SOP | HYDROGEN | ND | MOL % | 0.005 | ND | | SOP | ISOBUTANE | ND | MOL % | 0.005 | ND | | SOP | ISOPENTANE | ND | MOL % | 0.005 | ND | | SOP | METHANE | 29.99 | MOL % | 0.005 | | | SOP | NITROGEN (N2) | 63.37 | MOL % | 0.005 | | | SOP | OXYGEN + ARGON | 6.42 | MOL % | 0.005 | | | SOP | PENTANE | ND | MOL % | 0.005 | ND | | SOP | PROPANE | ND | MOL % | 0.005 | ND |
Sample ID: 642972 Sample Date: 08/29/2022 Matrix: WATER Collection Point: Dom Type: MIX Lab: | Sample Results for Sample # 642972 ID: L1530971-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | BART | BACTERIA, IRON RELATED | | cfu/ml | | | | BART | BACTERIA, SLIME FORMING | | cfu/ml | | | | BART | BACTERIA, SULFATE REDUCING | | cfu/ml | | | | E353.2 | NITRATE/NITRITE | ND | mg/L | 0.1 | U | | E365.4 | PHOSPHORUS | ND | mg/L | 0.1 | U | | RSK-175 | ETHANE | ND | mg/L | 0.013 | U | | RSK-175 | METHANE | 7.53 | mg/L | 0.1 | | | RSK-175 | PROPANE | ND | mg/L | 0.02 | U | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 192 | mg/L | 20 | | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | | SM2320B | TOTAL ALKALINITY AS CACO3 | 192 | mg/L | 20 | | | SM2540C | TOTAL DISSOLVED SOLIDS | 206 | mg/L | 10 | | | SW6010 | BARIUM | 0.0451 | mg/L | 0.005 | | | SW6010 | BORON | ND | mg/L | 0.2 | U | | SW6010 | CALCIUM | 5.82 | mg/L | 1 | | | SW6010 | IRON | ND | mg/L | 0.1 | U | | SW6010 | MAGNESIUM | ND | mg/L | 1 | U | | SW6010 | MANGANESE | 0.0158 | mg/L | 0.01 | | | SW6010 | POTASSIUM | ND | mg/L | 2 | U | | SW6010 | SODIUM | 79.3 | mg/L | 3 | | | SW6010 | STRONTIUM | 0.121 | mg/L | 0.01 | | | SW6020 | SELENIUM | ND | mg/L | 0.002 | U | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.1 | U | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.1 | U | | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | M-+P-XYLENE | ND | mg/L | 0.002 | U | | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U | | SW9040 | PH, LAB | 8.38 | SU | | T8 | | SW9050 | SPECIFIC CONDUCTIVITY | 361 | UMHOS/CM | 10 | | | SW9056 | BROMIDE | 1.09 | mg/L | 1 | | | SW9056 | CHLORIDE | 8.52 | mg/L | 1 | | | SW9056 | FLUORIDE | 1.5 | mg/L | 0.15 | | | SW9056 | NITRATE | ND | mg/L | 0.1 | U | | SW9056 | NITRITE | ND | mg/L | 0.1 | U | | SW9056 | SULFATE | ND | mg/L | 5 | U |
Sample ID: 642974 Sample Date: 08/29/2022 Matrix: WATER Collection Point: TB Type: TB Lab: | Sample Results for Sample # 642974 ID: L1530979-01 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW846 8260B | BENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | ETHYLBENZENE | ND | mg/L | 0.001 | U | | SW846 8260B | M-+P-XYLENE | ND | mg/L | 0.002 | U | | SW846 8260B | o-XYLENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOLUENE | ND | mg/L | 0.001 | U | | SW846 8260B | TOTAL XYLENES | ND | mg/L | 0.003 | U |
|
|