COGIS - Environmental Sample Site Information

 
#755147 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID755147
FacilityTypeDOMProj Number
CountyWELD - 123LocationNESE 23 1N67W
Elevation4971Lat/Long40.035614/-104.84944
DWR Receipt #0252963BWellDepth795
 
Related Facility/Well
API Number: 05- - Well Name:No Facility 1
Well Status:CLOperator Name:UNKNOWN
Location:      

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   554426     Sample Date:  10/27/2016     Matrix:  GAS     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 554426    ISOTECH ID: 586161
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.971MOL %0.005
SOPBRITISH THERMAL UNITS461BTU
SOPBUTANENDMOL %0.0001ND
SOPC6+ (hexanes +)NDMOL %0.0001ND
SOPCARBON DIOXIDE0.13MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-70.61
SOPDELTA D C1-253.8
SOPETHANE0.0569MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.65NA
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANENDMOL %0.0001ND
SOPISOPENTANENDMOL %0.0001ND
SOPMETHANE45.38MOL %0.0002
SOPNITROGEN (N2)51.77MOL %0.01
SOPOXYGEN (O2)1.69MOL %0.01
SOPPENTANENDMOL %0.0001ND
SOPPROPANE0.0003MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.787RATIO_AIR

 Sample ID:   554421     Sample Date:  10/27/2016     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 554421    Accutest ID: D88235-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   554427     Sample Date:  10/27/2016     Matrix:  WATER     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 554427    ISOTECH ID: 586161
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.71mg/L0.01
SOPETHANE0.034mg/L0.0002
SOPMETHANE13mg/L0.0002
SOPNITROGEN (N2)23mg/L0.01
SOPPROPANE0.0002mg/L0.0002

 Sample ID:   554423     Sample Date:  10/27/2016     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 554423    Accutest ID: D88234-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATED74500cfu/ml25
BARTBACTERIA, SLIME FORMINGNDcfu/ml500U
BARTBACTERIA, SULFATE REDUCING700cfu/ml200
E120.1SPECIFIC CONDUCTIVITY, FIELD897UMHOS/CM0.5
E150.1PH, LAB9.1SU
E170.1TEMPERATURE, FIELD19.86degrees C
E200.7BORON0.237mg/L0.05
E200.7CALCIUM1.04mg/L0.4
E200.7IRON0.0356mg/L0.01
E200.7MAGNESIUM0.424mg/L0.2
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUMNDmg/L1U
E200.7SODIUM208mg/L0.4
E200.7STRONTIUM0.0354mg/L0.005
E200.8BARIUM0.0274mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE0.45mg/L0.25
E300.0CHLORIDE41.8mg/L2.5
E300.0FLUORIDE1.5mg/L0.5
E300.0NITRATENDmg/L0.05U
E300.0NITRATE/NITRITE AS NNDmg/L0.07U
E300.0Nitrite as NO2NDmg/L0.02U
E300.0SULFATE1.2mg/L0.5
E360.1DISSOLVED OXYGEN, FIELD0.06mg/L
FIELDOXIDATION REDUCTION POTENTIAL-270mV
FIELDTURBIDITY0.95NTU
HACHPHOSPHORUSNDmg/L0.01U
RSK175ETHANE0.0018mg/L0.0016
RSK175METHANE4.14mg/L0.008
RSK175PROPANENDmg/L0.0022U
SM1030CATION - ANION BALANCE0.22%
SM2320BBICARBONATE ALKALINITY as CACO3324mg/L5
SM2320BCARBONATE ALKALINITY AS CACO371.6mg/L5
SM2320BTOTAL ALKALINITY AS CACO3396mg/L5
SM2510BSPECIFIC CONDUCTIVITY835UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS519mg/L10
SM4500-H+ BPH, LAB9.11SU
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.19U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   564951     Sample Date:  01/18/2018     Matrix:  GAS     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 564951    ISOTECH ID: 647045
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.891MOL %0.005
SOPBRITISH THERMAL UNITS483BTU
SOPBUTANENDMOL %0.0001ND
SOPC6+ (hexanes +)NDMOL %0.0001ND
SOPCARBON DIOXIDE0.13MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-72.18
SOPDELTA D C1-262.3
SOPETHANE0.0566MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.66NA
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANENDMOL %0.0001ND
SOPISOPENTANENDMOL %0.0001ND
SOPMETHANE47.59MOL %0.0002
SOPNITROGEN (N2)50.28MOL %0.01
SOPOXYGEN (O2)1.05MOL %0.01
SOPPENTANENDMOL %0.0001ND
SOPPROPANE0.0003MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.776RATIO_AIR

 Sample ID:   564952     Sample Date:  01/18/2018     Matrix:  WATER     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 564952    ISOTECH ID: 647045
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.64mg/L0.01
SOPETHANE0.034mg/L0.0002
SOPMETHANE14mg/L0.0002
SOPNITROGEN (N2)21mg/L0.01
SOPPROPANE0.0002mg/L0.0002

 Sample ID:   564946     Sample Date:  01/18/2018     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 564946    Accutest ID: DA2002-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   564948     Sample Date:  01/18/2018     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 564948    Accutest ID: DA2001-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATED9000cfu/ml25
BARTBACTERIA, SLIME FORMING6500cfu/ml500
BARTBACTERIA, SULFATE REDUCING5000cfu/ml200
E200.7BORON0.221mg/L0.05
E200.7CALCIUM0.926mg/L0.4
E200.7IRON0.0295mg/L0.01
E200.7MAGNESIUM0.323mg/L0.2
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUMNDmg/L1U
E200.7SODIUM202mg/L0.4
E200.7STRONTIUM0.0304mg/L0.005
E200.8BARIUM0.0204mg/L0.002
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE0.41mg/L0.05
E300.0CHLORIDE40.4mg/L2.5
E300.0FLUORIDE1.6mg/L0.1
E300.0NITRATENDmg/L0.01U
E300.0NITRATE/NITRITE AS NNDmg/L0.03U
E300.0Nitrite as NO2NDmg/L0.02U
E300.0SULFATE0.65mg/L0.5
E365.1PHOSPHORUS0.076mg/L0.01
FIELDDISSOLVED OXYGEN, FIELD0.13mg/L
FIELDOXIDATION REDUCTION POTENTIAL-250mV
FIELDpH, FIELD9SU
FIELDSPECIFIC CONDUCTIVITY, FIELD900UMHOS/CM0.5
FIELDTEMPERATURE, FIELD16.1degrees C
FIELDTURBIDITY0.59NTU
RSK175ETHANE0.0119mg/L0.0016
RSK175METHANE4.18mg/L0.008
RSK175PROPANENDmg/L0.0022U
SM1030CATION - ANION BALANCE2.4%
SM2320BBICARBONATE ALKALINITY as CACO3360mg/L5
SM2320BCARBONATE ALKALINITY AS CACO348.9mg/L5
SM2320BTOTAL ALKALINITY AS CACO3409mg/L5
SM2510BSPECIFIC CONDUCTIVITY885UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS536mg/L10
SM4500-H+ BpH, FIELD9.08SU
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.19U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U