|
Sample ID: 603290 Sample Date: 12/11/2018 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 603290 ISOTECH ID: 695318 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.522 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 851 | BTU | | | SOP | BUTANE | 0.076 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0098 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.58 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.57 | ‰ | | | SOP | DELTA 13C C2 | -30.23 | ‰ | | | SOP | DELTA 13C C3 | -24.02 | ‰ | | | SOP | DELTA D C1 | -235.5 | ‰ | | | SOP | ETHANE | 6.28 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.71 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.115 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0284 | MOL % | 0.0001 | | SOP | METHANE | 69.26 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 21.26 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.69 | MOL % | 0.01 | | SOP | PENTANE | 0.0074 | MOL % | 0.0001 | | SOP | PROPANE | 1.17 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.701 | RATIO_AIR | | |
Sample ID: 603291 Sample Date: 12/11/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 603291 ISOTECH ID: 695318 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.43 | mg/L | 0.01 | | SOP | ETHANE | 4.2 | mg/L | 0.0002 | | SOP | METHANE | 23 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 11 | mg/L | 0.02 | | SOP | PROPANE | 1.1 | mg/L | 0.0003 | |
Sample ID: 603288 Sample Date: 12/11/2018 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 603288 Accutest ID: DA11868-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 603289 Sample Date: 12/11/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 603289 Accutest ID: DA11867-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2200 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 325 | cfu/ml | 200 | | E200.7 | BORON | 0.235 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.73 | mg/L | 0.4 | | E200.7 | IRON | 0.0457 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.811 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0127 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.5 | mg/L | 1 | | E200.7 | SODIUM | 275 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0829 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0572 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.56 | mg/L | 0.25 | | E300.0 | CHLORIDE | 51.5 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.1 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 17 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.039 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -240 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1200 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 15.47 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.07 | mg/L | 0.08 | | RSK175 | METHANE | 8.82 | mg/L | 0.04 | | RSK175 | PROPANE | 0.567 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 0.71 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 494 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 35.3 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 529 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1150 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 699 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.71 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0945 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 605373 Sample Date: 12/11/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 605373 ISOTECH ID: 695299 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.2 | ‰ | | | SOP | DELTA 18O H2O | -13.67 | ‰ | | | SOP | DELTA D H2O | -104.5 | ‰ | | |
Sample ID: 563358 Sample Date: 11/16/2017 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 563358 ISOTECH ID: 638057 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.557 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 774 | BTU | | | SOP | BUTANE | 0.104 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0088 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.36 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -60.02 | ‰ | | | SOP | DELTA 13C C2 | -30.33 | ‰ | | | SOP | DELTA 13C C3 | -25.26 | ‰ | | | SOP | DELTA D C1 | -245 | ‰ | | | SOP | ETHANE | 4.21 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.68 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.105 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.031 | MOL % | 0.0001 | | SOP | METHANE | 65.81 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 27.19 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.69 | MOL % | 0.01 | | SOP | PENTANE | 0.0117 | MOL % | 0.0001 | | SOP | PROPANE | 0.918 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.712 | RATIO_AIR | | |
Sample ID: 563359 Sample Date: 11/16/2017 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 563359 ISOTECH ID: 638057 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.41 | mg/L | 0.01 | | SOP | ETHANE | 2.5 | mg/L | 0.0002 | | SOP | METHANE | 19 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 12 | mg/L | 0.01 | | SOP | PROPANE | 0.76 | mg/L | 0.0003 | |
Sample ID: 563395 Sample Date: 11/16/2017 Matrix: WATER Collection Point: TB Type: SMP Lab: AccutestSample Results for Sample # 563395 Accutest ID: DA174-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 563355 Sample Date: 11/16/2017 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 563355 Accutest ID: DA173-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 25 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 700 | cfu/ml | 200 | | E200.7 | BORON | 0.246 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.93 | mg/L | 0.4 | | E200.7 | IRON | 0.0696 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.562 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0083 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.21 | mg/L | 1 | | E200.7 | SODIUM | 242 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0615 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0411 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.5 | mg/L | 0.1 | | E300.0 | CHLORIDE | 47.5 | mg/L | 5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 4.5 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.047 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.1 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -51 | mV | | | FIELD | pH, FIELD | 9 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 832 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 16.1 | degrees C | | | FIELD | TURBIDITY | 2 | NTU | | | RSK175 | ETHANE | 1.17 | mg/L | 0.0016 | | RSK175 | METHANE | 7.12 | mg/L | 0.02 | | RSK175 | PROPANE | 0.367 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.2 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 445 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 43.3 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 488 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1020 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 637 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.8 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.126 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 606089 Sample Date: 11/16/2017 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 606089 ISOTECH ID: 638060 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11 | ‰ | | | SOP | DELTA 18O H2O | -13.7 | ‰ | | | SOP | DELTA D H2O | -104.4 | ‰ | | |
Sample ID: 555005 Sample Date: 11/02/2016 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 555005 ISOTECH ID: 586391 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.51 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 757 | BTU | | | SOP | BUTANE | 0.125 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0099 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.32 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -59.08 | ‰ | | | SOP | DELTA 13C C2 | -30.08 | ‰ | | | SOP | DELTA 13C C3 | -25.49 | ‰ | | | SOP | DELTA D C1 | -240.4 | ‰ | | | SOP | ETHANE | 4.67 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.66 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.105 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0299 | MOL % | 0.0001 | | SOP | METHANE | 63.05 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 28.85 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.31 | MOL % | 0.01 | | SOP | PENTANE | 0.0134 | MOL % | 0.0001 | | SOP | PROPANE | 1.01 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.725 | RATIO_AIR | | |
Sample ID: 555006 Sample Date: 11/02/2016 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 555006 ISOTECH ID: 586391 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.42 | mg/L | 0.01 | | SOP | ETHANE | 3.2 | mg/L | 0.0002 | | SOP | METHANE | 21 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 15 | mg/L | 0.01 | | SOP | PROPANE | 0.95 | mg/L | 0.0003 | |
Sample ID: 555000 Sample Date: 11/02/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 555000 Accutest ID: D88461-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 555002 Sample Date: 11/02/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 555002 Accutest ID: D88460-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 25 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 700 | cfu/ml | 200 | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 982 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.9 | SU | | | E170.1 | TEMPERATURE, FIELD | 18.29 | degrees C | | | E200.7 | BORON | 0.263 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.66 | mg/L | 0.4 | | E200.7 | IRON | 0.0688 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.401 | mg/L | 0.2 | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | E200.7 | POTASSIUM | 1.07 | mg/L | 1 | | E200.7 | SODIUM | 233 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0548 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0458 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.46 | mg/L | 0.1 | | E300.0 | CHLORIDE | 48.2 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 1.2 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.04 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | TURBIDITY | 1 | NTU | | | HACH | PHOSPHORUS | ND | mg/L | 0.01 | U | RSK175 | ETHANE | 1.07 | mg/L | 0.0016 | | RSK175 | METHANE | 6.03 | mg/L | 0.016 | | RSK175 | PROPANE | 0.36 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 1.81 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 431 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 33.1 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 464 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 942 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 593 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.68 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.211 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 607451 Sample Date: 11/02/2016 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 607451 ISOTECH ID: 586389 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.6 | ‰ | | | SOP | DELTA 18O H2O | -13.34 | ‰ | | | SOP | DELTA D H2O | -104.5 | ‰ | | |
Sample ID: 546685 Sample Date: 10/26/2015 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 546685 ISOTECH ID: 540123 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.464 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 787 | BTU | | | SOP | BUTANE | 0.118 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0062 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.28 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.9 | ‰ | | | SOP | DELTA 13C C2 | -30 | ‰ | | | SOP | DELTA 13C C3 | -25.31 | ‰ | | | SOP | DELTA D C1 | -242.8 | ‰ | | | SOP | ETHANE | 4.99 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.59 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.104 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0292 | MOL % | 0.0001 | | SOP | METHANE | 65.42 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 26.43 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.12 | MOL % | 0.01 | | SOP | PENTANE | 0.0121 | MOL % | 0.0001 | | SOP | PROPANE | 1.03 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.714 | RATIO_AIR | | |
Sample ID: 546661 Sample Date: 10/26/2015 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 546661 ISOTECH ID: 540123 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.464 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 787 | BTU | | | SOP | BUTANE | 0.118 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0062 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.28 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.9 | ‰ | | | SOP | DELTA 13C C2 | -30 | ‰ | | | SOP | DELTA 13C C3 | -25.31 | ‰ | | | SOP | DELTA D C1 | -242.8 | ‰ | | | SOP | ETHANE | 4.99 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.59 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.104 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0292 | MOL % | 0.0001 | | SOP | METHANE | 65.42 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 26.43 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.12 | MOL % | 0.01 | | SOP | PENTANE | 0.0121 | MOL % | 0.0001 | | SOP | PROPANE | 1.03 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.714 | RATIO_AIR | | |
Sample ID: 546662 Sample Date: 10/26/2015 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 546662 ISOTECH ID: 540123 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.43 | mg/L | 0.01 | | SOP | ETHANE | 3.8 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 15 | mg/L | 0.01 | | SOP | PROPANE | 1.1 | mg/L | 0.0003 | |
Sample ID: 546664 Sample Date: 10/26/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 546664 Accutest ID: D76649-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1010 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.8 | SU | | | E170.1 | TEMPERATURE, FIELD | 17.03 | degrees C | | | E200.7 | BORON | 0.284 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.66 | mg/L | 0.4 | | E200.7 | IRON | 0.0582 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.456 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0052 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.24 | mg/L | 1 | | E200.7 | SODIUM | 251 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0589 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0452 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.51 | mg/L | 0.1 | | E300.0 | CHLORIDE | 44 | mg/L | 5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 1 | | E300.0 | NITRATE | ND | mg/L | 0.1 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.11 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 2 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.1 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -160 | mV | | | FIELD | TURBIDITY | 0.52 | NTU | | | HACH | PHOSPHORUS | 0.049 | mg/L | 0.01 | | RSK175 | ETHANE | 1.91 | mg/L | 0.064 | | RSK175 | METHANE | 11.6 | mg/L | 0.032 | | RSK175 | PROPANE | 0.67 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.95 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 417 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 41.6 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 458 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 959 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 602 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.73 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.194 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 546686 Sample Date: 10/26/2015 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 546686 ISOTECH ID: 540123 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.43 | mg/L | 0.01 | | SOP | ETHANE | 3.8 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 15 | mg/L | 0.01 | | SOP | PROPANE | 1.1 | mg/L | 0.0003 | |
Sample ID: 546688 Sample Date: 10/26/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 546688 Accutest ID: D76649-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1010 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.8 | SU | | | E170.1 | TEMPERATURE, FIELD | 17.03 | degrees C | | | E200.7 | BORON | 0.284 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.66 | mg/L | 0.4 | | E200.7 | IRON | 0.0582 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.456 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0052 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.24 | mg/L | 1 | | E200.7 | SODIUM | 251 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0589 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0452 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.51 | mg/L | 0.1 | | E300.0 | CHLORIDE | 44 | mg/L | 5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 1 | | E300.0 | NITRATE | ND | mg/L | 0.1 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.11 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 2 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.1 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -160 | mV | | | FIELD | TURBIDITY | 0.52 | NTU | | | HACH | PHOSPHORUS | 0.049 | mg/L | 0.01 | | RSK175 | ETHANE | 1.91 | mg/L | 0.064 | | RSK175 | METHANE | 11.6 | mg/L | 0.032 | | RSK175 | PROPANE | 0.67 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.95 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 417 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 41.6 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 458 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 959 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 602 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.73 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.194 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 546700 Sample Date: 10/26/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 546700 Accutest ID: D76650-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 664504 Sample Date: 10/22/2024 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 664504 ISOTECH ID: 942036 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.672 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 693 | BTU | | | SOP | BUTANE | 0.0205 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0038 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.44 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -58.13 | ‰ | | | SOP | DELTA 13C C2 | -30.23 | ‰ | | | SOP | DELTA 13C C3 | -21.8 | ‰ | | | SOP | DELTA 13C iC4 | -27.5 | ‰ | | | SOP | DELTA D C1 | -231.7 | ‰ | | | SOP | ETHANE | 3.96 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.64 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.0025 | ND | SOP | ISOBUTANE | 0.103 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0233 | MOL % | 0.0001 | | SOP | METHANE | 59.55 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 33.48 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.19 | MOL % | 0.01 | | SOP | PENTANE | 0.0015 | MOL % | 0.0001 | | SOP | PROPANE | 0.568 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.736 | RATIO_AIR | | |
Sample ID: 664505 Sample Date: 10/22/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 664505 ISOTECH ID: 942036 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.62 | mg/L | 0.01 | | SOP | ETHANE | 3 | mg/L | 0.0002 | | SOP | METHANE | 22 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 19 | mg/L | 0.02 | | SOP | PROPANE | 0.6 | mg/L | 0.0003 | |
Sample ID: 664501 Sample Date: 10/22/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 664501 Accutest ID: DA68264-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 664502 Sample Date: 10/22/2024 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 664502 Accutest ID: DA68263-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 500 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0609 | mg/L | 0.002 | | E200.8 | BORON | 0.258 | mg/L | 0.04 | | E200.8 | CALCIUM | 2.93 | mg/L | 0.4 | | E200.8 | IRON | 0.114 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.886 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.021 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.28 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 287 | mg/L | 10 | | E200.8 | STRONTIUM | 0.0929 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.54 | mg/L | 0.1 | | E300.0 | CHLORIDE | 53.4 | mg/L | 1 | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | NITRITE | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 17.9 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.1 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.01 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -260 | mV | | | FIELD | pH, FIELD | 8.8 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1110 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 18.8 | degrees C | | | FIELD | TURBIDITY | 0.58 | NTU | | | RSK175 | ETHANE | 1.06 | mg/L | 0.0016 | | RSK175 | METHANE | 7.61 | mg/L | 0.04 | | RSK175 | PROPANE | 0.232 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 1.7 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 521 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 39.5 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 560 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1190 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 680 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.73 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.17 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0458 | mg/L | 0.05 | J | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 664503 Sample Date: 10/22/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 664503 ISOTECH ID: 941999 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12 | ‰ | | | SOP | DELTA 18O H2O | -13.63 | ‰ | | | SOP | DELTA D H2O | -104.2 | ‰ | | |
Sample ID: 612553 Sample Date: 10/21/2019 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 612553 ISOTECH ID: 738839 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.38 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 947 | BTU | | | SOP | BUTANE | 0.103 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0095 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.55 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -52.32 | ‰ | | | SOP | DELTA 13C C2 | -30.11 | ‰ | | | SOP | DELTA 13C C3 | -24.08 | ‰ | | | SOP | DELTA D C1 | -236.8 | ‰ | | | SOP | ETHANE | 8.32 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.69 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.156 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0396 | MOL % | 0.0001 | | SOP | METHANE | 73.97 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 14.74 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.21 | MOL % | 0.01 | | SOP | PENTANE | 0.0082 | MOL % | 0.0001 | | SOP | PROPANE | 1.51 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.684 | RATIO_AIR | | |
Sample ID: 612554 Sample Date: 10/21/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 612554 ISOTECH ID: 738839 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.3 | mg/L | 0.01 | | SOP | ETHANE | 5.3 | mg/L | 0.0002 | | SOP | METHANE | 23 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 7.2 | mg/L | 0.02 | | SOP | PROPANE | 1.3 | mg/L | 0.0003 | |
Sample ID: 612550 Sample Date: 10/21/2019 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 612550 Accutest ID: DA21328-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 612551 Sample Date: 10/21/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 612551 Accutest ID: DA21327-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 27000 | cfu/ml | 200 | | E200.7 | BORON | 0.251 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.81 | mg/L | 0.4 | | E200.7 | IRON | 0.0369 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.804 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0158 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.62 | mg/L | 1 | | E200.7 | SODIUM | 273 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0828 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0611 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.59 | mg/L | 0.5 | | E300.0 | CHLORIDE | 53.8 | mg/L | 5 | | E300.0 | FLUORIDE | 2.1 | mg/L | 1 | | E300.0 | NITRATE | ND | mg/L | 0.1 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.14 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 8.1 | mg/L | 5 | | E365.1 | PHOSPHORUS | 0.032 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -220 | mV | | | FIELD | pH, FIELD | 8.5 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1130 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 17.78 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.9 | mg/L | 0.08 | | RSK175 | METHANE | 10.7 | mg/L | 0.04 | | RSK175 | PROPANE | 0.73 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 1.5 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 507 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 33.9 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 541 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1110 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 674 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.62 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.125 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | 0.82 | ug/L | 1 | J | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 612552 Sample Date: 10/21/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 612552 ISOTECH ID: 738845 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.1 | ‰ | | | SOP | DELTA 18O H2O | -13.69 | ‰ | | | SOP | DELTA D H2O | -104.1 | ‰ | | |
Sample ID: 655162 Sample Date: 10/09/2023 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 655162 ISOTECH ID: 893012 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.618 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 772 | BTU | | | SOP | BUTANE | 0.0943 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0107 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.36 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -59.29 | ‰ | | | SOP | DELTA 13C C2 | -30.23 | ‰ | | | SOP | DELTA 13C C3 | -25.1 | ‰ | | | SOP | DELTA 13C iC4 | -27.9 | ‰ | | | SOP | DELTA 13C nC4 | -24.9 | ‰ | | | SOP | DELTA D C1 | -235.9 | ‰ | | | SOP | ETHANE | 4.33 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.68 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0927 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0244 | MOL % | 0.0001 | | SOP | METHANE | 65.63 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 26.67 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.31 | MOL % | 0.01 | | SOP | PENTANE | 0.0097 | MOL % | 0.0001 | | SOP | PROPANE | 0.854 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.713 | RATIO_AIR | | |
Sample ID: 655163 Sample Date: 10/09/2023 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 655163 ISOTECH ID: 893012 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.41 | mg/L | 0.01 | | SOP | ETHANE | 2.4 | mg/L | 0.0002 | | SOP | METHANE | 18 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 11 | mg/L | 0.01 | | SOP | PROPANE | 0.65 | mg/L | 0.0002 | |
Sample ID: 655158 Sample Date: 10/09/2023 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 655158 Accutest ID: DA59211-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 150 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0572 | mg/L | 0.002 | | E200.8 | BORON | 0.26 | mg/L | 0.04 | | E200.8 | CALCIUM | 1.88 | mg/L | 0.4 | | E200.8 | IRON | 0.0596 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.528 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.01 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.07 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 240 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0657 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.49 | mg/L | 0.25 | | E300.0 | CHLORIDE | 47.3 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.8 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | NITRITE | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 3.4 | mg/L | 2.5 | | E365.1 | PHOSPHORUS | 0.054 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.08 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -6.7 | mV | | | FIELD | pH, FIELD | 8.9 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1010 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 19.6 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.26 | mg/L | 0.08 | | RSK175 | METHANE | 8.1 | mg/L | 0.04 | B | RSK175 | PROPANE | 0.366 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 5.7 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 480 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 40 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 520 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1070 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 589 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.88 | SU | | | SW8015 | TVPH - Gasoline Range Organics | 0.0804 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 655159 Sample Date: 10/09/2023 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 655159 Accutest ID: DA59211-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.097 | U |
Sample ID: 655160 Sample Date: 10/09/2023 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 655160 Accutest ID: DA59214-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 655161 Sample Date: 10/09/2023 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 655161 ISOTECH ID: 893008 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11 | ‰ | | | SOP | DELTA 18O H2O | -13.67 | ‰ | | | SOP | DELTA D H2O | -103.7 | ‰ | | |
Sample ID: 621287 Sample Date: 10/08/2020 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 621287 Accutest ID: DA29636-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 621288 Sample Date: 10/08/2020 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 621288 Accutest ID: DA29635-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SM4500-P-E | PHOSPHORUS | 0.028 | mg/L | 0.02 | |
Sample ID: 621289 Sample Date: 10/08/2020 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 621289 Accutest ID: DA29635-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 27000 | cfu/ml | 200 | | E200.7 | BORON | 0.264 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.56 | mg/L | 0.4 | | E200.7 | IRON | 0.0373 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.755 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0131 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.36 | mg/L | 1 | | E200.7 | SODIUM | 274 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0816 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0533 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.56 | mg/L | 0.1 | | E300.0 | CHLORIDE | 46.6 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 5.8 | mg/L | 1 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -280 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1060 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 18.7 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 3.13 | mg/L | 0.016 | | RSK175 | METHANE | 10.6 | mg/L | 0.04 | | RSK175 | PROPANE | 0.318 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.1 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 470 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 35 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 505 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1030 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 676 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.79 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.136 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 621290 Sample Date: 10/08/2020 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 621290 ISOTECH ID: 773212 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12 | ‰ | | | SOP | DELTA 18O H2O | -13.7 | ‰ | | | SOP | DELTA D H2O | -104.8 | ‰ | | |
Sample ID: 621291 Sample Date: 10/08/2020 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 621291 ISOTECH ID: 773220 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.325 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 895 | BTU | | | SOP | BUTANE | 0.45 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0106 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.66 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -51.84 | ‰ | | | SOP | DELTA 13C C2 | -30.12 | ‰ | | | SOP | DELTA 13C C3 | -23.96 | ‰ | | | SOP | DELTA 13C iC4 | -27.7 | ‰ | | | SOP | Delta 13C iC5 | -25.8 | ‰ | | | SOP | DELTA 13C nC4 | -23.7 | ‰ | | | SOP | DELTA D C1 | -232.8 | ‰ | | | SOP | ETHANE | 4.94 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.65 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.254 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0644 | MOL % | 0.0001 | | SOP | METHANE | 72.04 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 16.46 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 2.81 | MOL % | 0.01 | | SOP | PENTANE | 0.0458 | MOL % | 0.0001 | | SOP | PROPANE | 1.94 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.702 | RATIO_AIR | | |
Sample ID: 621292 Sample Date: 10/08/2020 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 621292 ISOTECH ID: 773220 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.27 | mg/L | 0.01 | | SOP | ETHANE | 3.3 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 8.3 | mg/L | 0.01 | | SOP | PROPANE | 1.8 | mg/L | 0.0003 | |
Sample ID: 644898 Sample Date: 10/05/2022 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 644898 ISOTECH ID: 845261 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.554 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 739 | BTU | | | SOP | BUTANE | 0.1 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0094 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.56 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.05 | ‰ | | | SOP | DELTA 13C C2 | -30.03 | ‰ | | | SOP | DELTA 13C C3 | -24.56 | ‰ | | | SOP | DELTA 13C iC4 | -27.8 | ‰ | | | SOP | Delta 13C iC5 | -25.5 | ‰ | | | SOP | DELTA 13C nC4 | -23.5 | ‰ | | | SOP | DELTA D C1 | -225.7 | ‰ | | | SOP | ETHANE | 5.53 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.69 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.147 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0403 | MOL % | 0.0001 | | SOP | METHANE | 59.41 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 26.55 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 5.97 | MOL % | 0.01 | | SOP | PENTANE | 0.01 | MOL % | 0.0001 | | SOP | PROPANE | 1.12 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.749 | RATIO_AIR | | |
Sample ID: 644899 Sample Date: 10/05/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 644899 ISOTECH ID: 845261 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.59 | mg/L | 0.02 | | SOP | ETHANE | 4.7 | mg/L | 0.0003 | | SOP | METHANE | 25 | mg/L | 0.0003 | | SOP | NITROGEN (N2) | 18 | mg/L | 0.02 | | SOP | PROPANE | 1.3 | mg/L | 0.0004 | |
Sample ID: 644895 Sample Date: 10/05/2022 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 644895 Accutest ID: DA49831-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 644896 Sample Date: 10/05/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 644896 Accutest ID: DA49830-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0605 | mg/L | 0.004 | | E200.8 | BORON | 0.258 | mg/L | 0.08 | | E200.8 | CALCIUM | 2.61 | mg/L | 0.8 | | E200.8 | IRON | 0.0869 | mg/L | 0.04 | | E200.8 | MAGNESIUM | 0.778 | mg/L | 0.2 | | E200.8 | MANGANESE | 0.0132 | mg/L | 0.002 | | E200.8 | POTASSIUM | 1.41 | mg/L | 0.4 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E200.8 | SODIUM | 287 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0851 | mg/L | 0.04 | | E300.0 | BROMIDE | 0.57 | mg/L | 0.1 | | E300.0 | CHLORIDE | 49 | mg/L | 13 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.12 | U | E300.0 | NITRITE | ND | mg/L | 0.1 | U | E300.0 | SULFATE | 9.1 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.034 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -260 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1140 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 19.09 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.8 | mg/L | 0.08 | | RSK175 | METHANE | 8.06 | mg/L | 0.04 | | RSK175 | PROPANE | 0.501 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 3.4 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 481 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 30 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 511 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1150 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 672 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.65 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.125 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 644897 Sample Date: 10/05/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 644897 ISOTECH ID: 845260 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.1 | ‰ | | | SOP | DELTA 18O H2O | -13.74 | ‰ | | | SOP | DELTA D H2O | -104 | ‰ | | |
Sample ID: 631783 Sample Date: 10/04/2021 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 631783 ISOTECH ID: 806014 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.361 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 928 | BTU | | | SOP | BUTANE | 0.108 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0156 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.44 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -51.86 | ‰ | | | SOP | DELTA 13C C2 | -30.02 | ‰ | | | SOP | DELTA 13C C3 | -24.18 | ‰ | | | SOP | DELTA 13C iC4 | -27.4 | ‰ | | | SOP | Delta 13C iC5 | -25.7 | ‰ | | | SOP | DELTA 13C nC4 | -22.2 | ‰ | | | SOP | DELTA D C1 | -231.5 | ‰ | | | SOP | ETHANE | 8.27 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.65 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.192 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0547 | MOL % | 0.0001 | | SOP | METHANE | 71.7 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 15.72 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.53 | MOL % | 0.01 | | SOP | PENTANE | 0.0092 | MOL % | 0.0001 | | SOP | PROPANE | 1.6 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.696 | RATIO_AIR | | |
Sample ID: 631784 Sample Date: 10/04/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 631784 ISOTECH ID: 806014 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.3 | mg/L | 0.01 | | SOP | ETHANE | 5.7 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 8.1 | mg/L | 0.01 | | SOP | PROPANE | 1.5 | mg/L | 0.0003 | |
Sample ID: 631780 Sample Date: 10/04/2021 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 631780 Accutest ID: DA38029-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 631781 Sample Date: 10/04/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 631781 Accutest ID: DA38030-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 1400 | cfu/ml | 200 | | E200.8 | BARIUM | 0.0592 | mg/L | 0.004 | | E200.8 | BORON | 0.244 | mg/L | 0.08 | | E200.8 | CALCIUM | 2.69 | mg/L | 0.8 | | E200.8 | IRON | ND | mg/L | 0.08 | U | E200.8 | MAGNESIUM | 0.819 | mg/L | 0.2 | | E200.8 | MANGANESE | 0.0137 | mg/L | 0.002 | | E200.8 | POTASSIUM | 1.37 | mg/L | 0.4 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E200.8 | SODIUM | 348 | mg/L | 13 | | E200.8 | STRONTIUM | 0.086 | mg/L | 0.04 | | E300.0 | BROMIDE | 0.44 | mg/L | 0.1 | | E300.0 | CHLORIDE | 55.8 | mg/L | 5 | | E300.0 | FLUORIDE | 1.5 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | NITRITE | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 6.5 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.044 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.02 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -91 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1150 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 20.09 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 3.15 | mg/L | 0.016 | | RSK175 | METHANE | 12.4 | mg/L | 0.04 | | RSK175 | PROPANE | 0.863 | mg/L | 0.022 | | SM1030 | CATION - ANION BALANCE | 14.1 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 450 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 40 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 490 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1030 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 713 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.77 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.117 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 631782 Sample Date: 10/04/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 631782 ISOTECH ID: 806008 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.1 | ‰ | | | SOP | DELTA 18O H2O | -13.73 | ‰ | | | SOP | DELTA D H2O | -104 | ‰ | | |
Sample ID: 602539 Sample Date: 09/11/2018 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 602539 ISOTECH ID: 682729 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.483 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 817 | BTU | | | SOP | BUTANE | 0.154 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0177 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.33 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -56.92 | ‰ | | | SOP | DELTA 13C C2 | -30.17 | ‰ | | | SOP | DELTA 13C C3 | -25.56 | ‰ | | | SOP | DELTA D C1 | -238.1 | ‰ | | | SOP | ETHANE | 5.3 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.67 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.139 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.043 | MOL % | 0.0001 | | SOP | METHANE | 67.01 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 23.26 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 2.03 | MOL % | 0.01 | | SOP | PENTANE | 0.0177 | MOL % | 0.0001 | | SOP | PROPANE | 1.22 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.712 | RATIO_AIR | | |
Sample ID: 602540 Sample Date: 09/11/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 602540 ISOTECH ID: 682729 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.43 | mg/L | 0.01 | | SOP | ETHANE | 3.9 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 13 | mg/L | 0.02 | | SOP | PROPANE | 1.2 | mg/L | 0.0003 | |
Sample ID: 605372 Sample Date: 09/11/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 605372 ISOTECH ID: 682728 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.9 | ‰ | | | SOP | DELTA 18O H2O | -13.69 | ‰ | | | SOP | DELTA D H2O | -104.7 | ‰ | | |
Sample ID: 602537 Sample Date: 09/11/2018 Matrix: WATER Collection Point: TB Type: SMP Lab: AccutestSample Results for Sample # 602537 Accutest ID: DA9068-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 602538 Sample Date: 09/11/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 602538 Accutest ID: DA9067-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2200 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 13000 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 27000 | cfu/ml | 200 | | E200.7 | BORON | 0.229 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.7 | mg/L | 0.4 | | E200.7 | IRON | 0.0481 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.441 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0069 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.16 | mg/L | 1 | | E200.7 | SODIUM | 223 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0522 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0443 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.49 | mg/L | 0.25 | | E300.0 | CHLORIDE | 47.6 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 2.2 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.051 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.04 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -180 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1080 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 19.7 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.69 | mg/L | 0.04 | | RSK175 | METHANE | 8.24 | mg/L | 0.02 | | RSK175 | PROPANE | 0.556 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 4.5 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 437 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 33 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 470 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 960 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 607 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.8 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.177 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 553734 Sample Date: 07/27/2016 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 553734 ISOTECH ID: 575994 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.605 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 671 | BTU | | | SOP | BUTANE | 0.0624 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0048 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.35 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -62.89 | ‰ | | | SOP | DELTA 13C C2 | -30.31 | ‰ | | | SOP | DELTA 13C C3 | -24.9 | ‰ | | | SOP | DELTA D C1 | -246.6 | ‰ | | | SOP | ETHANE | 2.59 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.68 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.0617 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0169 | MOL % | 0.0001 | | SOP | METHANE | 59.81 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 34.35 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.6 | MOL % | 0.01 | | SOP | PENTANE | 0.0067 | MOL % | 0.0001 | | SOP | PROPANE | 0.539 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.733 | RATIO_AIR | | |
Sample ID: 553735 Sample Date: 07/27/2016 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 553735 ISOTECH ID: 575994 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.5 | mg/L | 0.01 | | SOP | ETHANE | 1.7 | mg/L | 0.0002 | | SOP | METHANE | 20 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 18 | mg/L | 0.02 | | SOP | PROPANE | 0.5 | mg/L | 0.0003 | |
Sample ID: 553729 Sample Date: 07/27/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 553729 Accutest ID: D85081-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 553731 Sample Date: 07/27/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 553731 Accutest ID: D85080-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2300 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 12500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 359000 | cfu/ml | 200 | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1010 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.7 | SU | | | E170.1 | TEMPERATURE, FIELD | 19.54 | degrees C | | | E200.7 | BORON | 0.252 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.47 | mg/L | 0.4 | | E200.7 | IRON | 0.0547 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.407 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0055 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.19 | mg/L | 1 | | E200.7 | SODIUM | 258 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0538 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0436 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.5 | mg/L | 0.05 | | E300.0 | CHLORIDE | 45 | mg/L | 10 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.1 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.1 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.08 | U | E300.0 | SULFATE | 0.81 | mg/L | 0.5 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -13 | mV | | | FIELD | TURBIDITY | 2.2 | NTU | | | HACH | PHOSPHORUS | 0.059 | mg/L | 0.01 | | RSK175 | ETHANE | 0.372 | mg/L | 0.0016 | | RSK175 | METHANE | 4.97 | mg/L | 0.016 | | RSK175 | PROPANE | 0.113 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 4.23 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 420 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 38.1 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 458 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 880 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 607 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.91 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 607450 Sample Date: 07/27/2016 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 607450 ISOTECH ID: 575226 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.6 | ‰ | | | SOP | DELTA 18O H2O | -13.67 | ‰ | | | SOP | DELTA D H2O | -105.5 | ‰ | | |
Sample ID: 609545 Sample Date: 07/24/2019 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 609545 ISOTECH ID: 727824 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.571 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 791 | BTU | | | SOP | BUTANE | 0.104 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0094 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.45 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -58.3 | ‰ | | | SOP | DELTA 13C C2 | -30.38 | ‰ | | | SOP | DELTA 13C C3 | -26 | ‰ | | | SOP | DELTA D C1 | -238.7 | ‰ | | | SOP | ETHANE | 5.04 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.75 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0873 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.022 | MOL % | 0.0001 | | SOP | METHANE | 65.98 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 24.16 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 2.58 | MOL % | 0.01 | | SOP | PENTANE | 0.0098 | MOL % | 0.0001 | | SOP | PROPANE | 0.988 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.715 | RATIO_AIR | | |
Sample ID: 609546 Sample Date: 07/24/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 609546 ISOTECH ID: 727824 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.36 | mg/L | 0.01 | | SOP | ETHANE | 2.6 | mg/L | 0.0002 | | SOP | METHANE | 17 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 9.5 | mg/L | 0.02 | | SOP | PROPANE | 0.71 | mg/L | 0.0003 | |
Sample ID: 609542 Sample Date: 07/24/2019 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 609542 Accutest ID: DA17970-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 609543 Sample Date: 07/24/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 609543 Accutest ID: DA17969-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 6000 | cfu/ml | 200 | | E200.7 | BORON | 0.23 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.77 | mg/L | 0.4 | | E200.7 | IRON | 0.0575 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.56 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0083 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.22 | mg/L | 1 | | E200.7 | SODIUM | 215 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0498 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0408 | mg/L | 0.004 | | E200.8 | SELENIUM | 0.0012 | mg/L | 0.0008 | | E300.0 | BROMIDE | 0.48 | mg/L | 0.1 | | E300.0 | CHLORIDE | 46.2 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 1.8 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.068 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.05 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -220 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1080 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 21.44 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.22 | mg/L | 0.04 | | RSK175 | METHANE | 5.59 | mg/L | 0.02 | | RSK175 | PROPANE | 0.394 | mg/L | 0.055 | | SM1030 | CATION - ANION BALANCE | 6.1 | % | | * | SM2320B | BICARBONATE ALKALINITY as CACO3 | 437 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 33.6 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 471 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 932 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 617 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.81 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.127 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 609544 Sample Date: 07/24/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 609544 ISOTECH ID: 727822 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.8 | ‰ | | | SOP | DELTA 18O H2O | -13.71 | ‰ | | | SOP | DELTA D H2O | -104.5 | ‰ | | |
Sample ID: 653335 Sample Date: 07/13/2023 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 653335 ISOTECH ID: 881920 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.671 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 696 | BTU | | | SOP | BUTANE | 0.0755 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0092 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.4 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -60.86 | ‰ | | | SOP | DELTA 13C C2 | -30.17 | ‰ | | | SOP | DELTA 13C C3 | -25.6 | ‰ | | | SOP | DELTA 13C iC4 | -27.8 | ‰ | | | SOP | DELTA 13C nC4 | -24.5 | ‰ | | | SOP | DELTA D C1 | -231.4 | ‰ | | | SOP | ETHANE | 3.52 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.71 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0724 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0411 | MOL % | 0.0001 | | SOP | METHANE | 60.03 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 30.22 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 4.25 | MOL % | 0.01 | | SOP | PENTANE | 0.0075 | MOL % | 0.0001 | | SOP | PROPANE | 0.706 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.739 | RATIO_AIR | | |
Sample ID: 653336 Sample Date: 07/13/2023 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 653336 ISOTECH ID: 881920 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.46 | mg/L | 0.01 | | SOP | ETHANE | 2 | mg/L | 0.0002 | | SOP | METHANE | 17 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 13 | mg/L | 0.01 | | SOP | PROPANE | 0.56 | mg/L | 0.0003 | |
Sample ID: 653337 Sample Date: 07/13/2023 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 653337 ISOTECH ID: 881910 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.8 | ‰ | | | SOP | DELTA 18O H2O | -13.79 | ‰ | | | SOP | DELTA D H2O | -104.8 | ‰ | | |
Sample ID: 653333 Sample Date: 07/13/2023 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 653333 Accutest ID: DA56911-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 325 | cfu/ml | 200 | | E200.8 | BARIUM | 0.0457 | mg/L | 0.002 | | E200.8 | BORON | 0.254 | mg/L | 0.04 | | E200.8 | CALCIUM | 1.7 | mg/L | 0.4 | | E200.8 | IRON | 0.0719 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.444 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.0091 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.07 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 253 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0649 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.5 | mg/L | 0.25 | | E300.0 | CHLORIDE | 47.3 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.8 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | NITRITE | ND | mg/L | 0.02 | U | E300.0 | SULFATE | ND | mg/L | 2.5 | U | E365.1 | PHOSPHORUS | 0.05 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.04 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -270 | mV | | | FIELD | pH, FIELD | 8.9 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1270 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 20.1 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 0.86 | mg/L | 0.08 | | RSK175 | METHANE | 5.69 | mg/L | 0.04 | | RSK175 | PROPANE | 0.26 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 0.54 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 440 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 50 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 490 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1090 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 600 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.86 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0758 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 653334 Sample Date: 07/13/2023 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 653334 Accutest ID: DA56918-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 662506 Sample Date: 07/11/2024 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 662506 ISOTECH ID: 930149 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.652 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 648 | BTU | | | SOP | BUTANE | 0.0569 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0051 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.46 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -62.41 | ‰ | | | SOP | DELTA 13C C2 | -30.39 | ‰ | | | SOP | DELTA 13C C3 | -25.4 | ‰ | | | SOP | DELTA 13C iC4 | -28 | ‰ | | | SOP | DELTA 13C nC4 | -24.4 | ‰ | | | SOP | DELTA D C1 | -240 | ‰ | | | SOP | ETHANE | 2.63 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.73 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.0025 | ND | SOP | ISOBUTANE | 0.0598 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0152 | MOL % | 0.0001 | | SOP | METHANE | 57.61 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 34.23 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 3.76 | MOL % | 0.01 | | SOP | PENTANE | 0.0061 | MOL % | 0.0001 | | SOP | PROPANE | 0.517 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.746 | RATIO_AIR | | |
Sample ID: 662507 Sample Date: 07/11/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 662507 ISOTECH ID: 930149 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.51 | mg/L | 0.01 | | SOP | ETHANE | 1.7 | mg/L | 0.0002 | | SOP | METHANE | 18 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 17 | mg/L | 0.02 | | SOP | PROPANE | 0.46 | mg/L | 0.0003 | |
Sample ID: 662503 Sample Date: 07/11/2024 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 662503 Accutest ID: DA65658-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 150 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0484 | mg/L | 0.002 | | E200.8 | BORON | 0.257 | mg/L | 0.04 | | E200.8 | CALCIUM | 1.6 | mg/L | 0.4 | | E200.8 | IRON | 0.0611 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.406 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.0076 | mg/L | 0.001 | | E200.8 | POTASSIUM | 0.994 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 241 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0585 | mg/L | 0.02 | | E300.0 | BROMIDE | ND | mg/L | 0.5 | U | E300.0 | CHLORIDE | 44.3 | mg/L | 5 | | E300.0 | FLUORIDE | 1.7 | mg/L | 0.1 | | E300.0 | NITRATE | ND | mg/L | 0.1 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.14 | U | E300.0 | NITRITE | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 1.4 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.036 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.06 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -92 | mV | | | FIELD | pH, FIELD | 8.8 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 978 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 19.3 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 0.866 | mg/L | 0.0016 | | RSK175 | METHANE | 6.71 | mg/L | 0.04 | | RSK175 | PROPANE | 0.213 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 3.7 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 469 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 34.9 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 504 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1040 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 568 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.86 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0961 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 662504 Sample Date: 07/11/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 662504 Accutest ID: DA65659-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 662505 Sample Date: 07/11/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 662505 ISOTECH ID: 930106 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.7 | ‰ | | | SOP | DELTA 18O H2O | -13.73 | ‰ | | | SOP | DELTA D H2O | -104.7 | ‰ | | |
Sample ID: 643254 Sample Date: 07/11/2022 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 643254 ISOTECH ID: 834768 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.718 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 587 | BTU | | | SOP | BUTANE | 0.0606 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0071 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.41 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -62.33 | ‰ | | | SOP | DELTA 13C C2 | -30.22 | ‰ | | | SOP | DELTA 13C C3 | -24.6 | ‰ | | | SOP | DELTA 13C iC4 | -27.8 | ‰ | | | SOP | DELTA 13C nC4 | -24.4 | ‰ | | | SOP | DELTA D C1 | -243.1 | ‰ | | | SOP | ETHANE | 2.49 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.72 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0606 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0167 | MOL % | 0.0001 | | SOP | METHANE | 51.8 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 35.8 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 8.11 | MOL % | 0.01 | | SOP | PENTANE | 0.0067 | MOL % | 0.0001 | | SOP | PROPANE | 0.516 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.776 | RATIO_AIR | | |
Sample ID: 643255 Sample Date: 07/11/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 643255 ISOTECH ID: 834768 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.6 | mg/L | 0.01 | | SOP | ETHANE | 1.7 | mg/L | 0.0002 | | SOP | METHANE | 17 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 19 | mg/L | 0.02 | | SOP | PROPANE | 0.48 | mg/L | 0.0003 | |
Sample ID: 643260 Sample Date: 07/11/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 643260 Accutest ID: DA46983-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2200 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0468 | mg/L | 0.004 | | E200.8 | BORON | 0.269 | mg/L | 0.08 | | E200.8 | CALCIUM | 1.76 | mg/L | 0.8 | | E200.8 | IRON | 0.128 | mg/L | 0.04 | | E200.8 | MAGNESIUM | 0.443 | mg/L | 0.2 | | E200.8 | MANGANESE | 0.007 | mg/L | 0.002 | | E200.8 | POTASSIUM | 1.15 | mg/L | 0.4 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E200.8 | SODIUM | 268 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0585 | mg/L | 0.04 | | E300.0 | BROMIDE | 0.56 | mg/L | 0.1 | | E300.0 | CHLORIDE | 46.4 | mg/L | 13 | | E300.0 | FLUORIDE | 1.8 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | NITRITE | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 1.2 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.052 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | pH, FIELD | 8.9 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1020 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 18.77 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 0.648 | mg/L | 0.08 | | RSK175 | METHANE | 5.39 | mg/L | 0.04 | | RSK175 | PROPANE | 0.534 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 4.9 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 423 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 40 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 463 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1010 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 572 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.87 | SU | | | SW8015 | TVPH - Gasoline Range Organics | 0.0598 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 643261 Sample Date: 07/11/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 643261 Accutest ID: DA46983-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U |
Sample ID: 643251 Sample Date: 07/11/2022 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 643251 Accutest ID: DA46986-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 643253 Sample Date: 07/11/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 643253 ISOTECH ID: 834750 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.6 | ‰ | | | SOP | DELTA 18O H2O | -13.69 | ‰ | | | SOP | DELTA D H2O | -104.6 | ‰ | | |
Sample ID: 618398 Sample Date: 07/08/2020 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 618398 ISOTECH ID: 764890 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.376 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 872 | BTU | | | SOP | BUTANE | 0.135 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0134 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.41 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -53.11 | ‰ | | | SOP | DELTA 13C C2 | -30.1 | ‰ | | | SOP | DELTA 13C C3 | -24.69 | ‰ | | | SOP | DELTA 13C iC4 | -27.6 | ‰ | | | SOP | Delta 13C iC5 | -26.4 | ‰ | | | SOP | DELTA 13C nC4 | -24.1 | ‰ | | | SOP | DELTA D C1 | -228.4 | ‰ | | | SOP | ETHANE | 7 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.65 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.139 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0383 | MOL % | 0.0001 | | SOP | METHANE | 69.37 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 20.2 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.02 | MOL % | 0.01 | | SOP | PENTANE | 0.0123 | MOL % | 0.0001 | | SOP | PROPANE | 1.29 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.702 | RATIO_AIR | | |
Sample ID: 618399 Sample Date: 07/08/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 618399 ISOTECH ID: 764890 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.41 | mg/L | 0.02 | | SOP | ETHANE | 6.1 | mg/L | 0.0002 | | SOP | METHANE | 30 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 14 | mg/L | 0.02 | | SOP | PROPANE | 1.6 | mg/L | 0.0003 | |
Sample ID: 618395 Sample Date: 07/08/2020 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 618395 Accutest ID: DA27232-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 618396 Sample Date: 07/08/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 618396 Accutest ID: DA27231-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 27000 | cfu/ml | 200 | | E200.7 | BORON | 0.253 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.24 | mg/L | 0.4 | | E200.7 | IRON | 0.0434 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.677 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0155 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.15 | mg/L | 1 | | E200.7 | SODIUM | 265 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0704 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0538 | mg/L | 0.004 | | E200.8 | SELENIUM | 0.0022 | mg/L | 0.0008 | | E300.0 | BROMIDE | 0.53 | mg/L | 0.25 | | E300.0 | CHLORIDE | 51.4 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 3.7 | mg/L | 2.5 | | E365.1 | PHOSPHORUS | 0.042 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -270 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1100 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 20.4 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.23 | mg/L | 0.016 | | RSK175 | METHANE | 7.23 | mg/L | 0.04 | | RSK175 | PROPANE | 0.577 | mg/L | 0.022 | | SM1030 | CATION - ANION BALANCE | 1.7 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 457 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 27.8 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 485 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1140 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 647 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.71 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.134 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 618397 Sample Date: 07/08/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 618397 ISOTECH ID: 764889 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.7 | ‰ | | | SOP | DELTA 18O H2O | -13.7 | ‰ | | | SOP | DELTA D H2O | -104.3 | ‰ | | |
Sample ID: 628491 Sample Date: 07/06/2021 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 628491 ISOTECH ID: 797211 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.525 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 782 | BTU | | | SOP | BUTANE | 0.124 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0121 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.46 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.88 | ‰ | | | SOP | DELTA 13C C2 | -30.23 | ‰ | | | SOP | DELTA 13C C3 | -25.51 | ‰ | | | SOP | DELTA 13C iC4 | -27.8 | ‰ | | | SOP | DELTA 13C nC4 | -24.5 | ‰ | | | SOP | DELTA D C1 | -230.4 | ‰ | | | SOP | ETHANE | 5.17 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.74 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.109 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0299 | MOL % | 0.0001 | | SOP | METHANE | 64.49 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 24.69 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 3.31 | MOL % | 0.01 | | SOP | PENTANE | 0.0117 | MOL % | 0.0001 | | SOP | PROPANE | 1.07 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.723 | RATIO_AIR | | |
Sample ID: 628492 Sample Date: 07/06/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 628492 ISOTECH ID: 797211 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.39 | mg/L | 0.01 | | SOP | ETHANE | 3.1 | mg/L | 0.0002 | | SOP | METHANE | 19 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 11 | mg/L | 0.02 | | SOP | PROPANE | 0.9 | mg/L | 0.0003 | |
Sample ID: 628490 Sample Date: 07/06/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 628490 ISOTECH ID: 797210 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.8 | ‰ | | | SOP | DELTA 18O H2O | -13.57 | ‰ | | | SOP | DELTA D H2O | -103.4 | ‰ | | |
Sample ID: 601528 Sample Date: 06/04/2018 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 601528 Accutest ID: DA5915-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 601531 Sample Date: 06/04/2018 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 601531 ISOTECH ID: 666659 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.492 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 772 | BTU | | | SOP | BUTANE | 0.131 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0099 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.28 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -58.53 | ‰ | | | SOP | DELTA 13C C2 | -30.18 | ‰ | | | SOP | DELTA 13C C3 | -25.53 | ‰ | | | SOP | DELTA D C1 | -242.1 | ‰ | | | SOP | ETHANE | 4.58 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.61 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.115 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0319 | MOL % | 0.0001 | | SOP | METHANE | 64.47 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 27.28 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.55 | MOL % | 0.01 | | SOP | PENTANE | 0.0144 | MOL % | 0.0001 | | SOP | PROPANE | 1.05 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.719 | RATIO_AIR | | |
Sample ID: 601529 Sample Date: 06/04/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 601529 Accutest ID: DA5914-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 6500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 5000 | cfu/ml | 200 | | E200.7 | BORON | 0.286 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.82 | mg/L | 0.4 | | E200.7 | IRON | 0.0624 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.478 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.005 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.31 | mg/L | 1 | | E200.7 | SODIUM | 271 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0597 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0459 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.41 | mg/L | 0.05 | | E300.0 | CHLORIDE | 45.9 | mg/L | 5 | | E300.0 | FLUORIDE | 2 | mg/L | 1 | | E300.0 | NITRATE | ND | mg/L | 0.01 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.05 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 1.2 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.053 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.02 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -180 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1030 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 18.59 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.28 | mg/L | 0.0016 | | RSK175 | METHANE | 7.08 | mg/L | 0.016 | | RSK175 | PROPANE | 0.397 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 5.8 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 439 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 28.4 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 467 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 896 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 585 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.74 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.122 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 601530 Sample Date: 06/04/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 601530 ISOTECH ID: 666659 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.46 | mg/L | 0.01 | | SOP | ETHANE | 3.5 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 16 | mg/L | 0.01 | | SOP | PROPANE | 1.1 | mg/L | 0.0003 | |
Sample ID: 605371 Sample Date: 06/04/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 605371 ISOTECH ID: 666644 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.7 | ‰ | | | SOP | DELTA 18O H2O | -13.71 | ‰ | | | SOP | DELTA D H2O | -104.5 | ‰ | | |
Sample ID: 608097 Sample Date: 05/08/2019 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 608097 ISOTECH ID: 718633 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.476 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 827 | BTU | | | SOP | BUTANE | 0.0855 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0104 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.32 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.54 | ‰ | | | SOP | DELTA 13C C2 | -30.1 | ‰ | | | SOP | DELTA 13C C3 | -23.01 | ‰ | | | SOP | DELTA D C1 | -226.1 | ‰ | | | SOP | ETHANE | 5.7 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.55 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.0959 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0277 | MOL % | 0.0001 | | SOP | METHANE | 68.21 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 23.97 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.037 | MOL % | 0.01 | | SOP | PENTANE | 0.0082 | MOL % | 0.0001 | | SOP | PROPANE | 1.06 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.702 | RATIO_AIR | | |
Sample ID: 608098 Sample Date: 05/08/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 608098 ISOTECH ID: 718633 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.53 | mg/L | 0.01 | | SOP | ETHANE | 5.2 | mg/L | 0.0002 | | SOP | METHANE | 31 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 16 | mg/L | 0.02 | | SOP | PROPANE | 1.3 | mg/L | 0.0003 | |
Sample ID: 608094 Sample Date: 05/08/2019 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 608094 Accutest ID: DA15732-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 608095 Sample Date: 05/08/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 608095 Accutest ID: DA15731-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 2500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 115000 | cfu/ml | 200 | | E200.7 | BORON | 0.238 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.56 | mg/L | 0.4 | | E200.7 | IRON | 0.0483 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.727 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0137 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.57 | mg/L | 1 | | E200.7 | SODIUM | 267 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0756 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0563 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.58 | mg/L | 0.1 | | E300.0 | CHLORIDE | 57.8 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 7.8 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.044 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.14 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1120 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 15.9 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.04 | mg/L | 0.08 | | RSK175 | METHANE | 8.39 | mg/L | 0.04 | | RSK175 | PROPANE | 0.505 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 1.2 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 483 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 33.3 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 517 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1100 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 661 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.73 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.109 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 608096 Sample Date: 05/08/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 608096 ISOTECH ID: 718624 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12 | ‰ | | | SOP | DELTA 18O H2O | -13.18 | ‰ | | | SOP | DELTA D H2O | -103.4 | ‰ | | |
Sample ID: 558190 Sample Date: 05/02/2017 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 558190 ISOTECH ID: 610348 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.468 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 799 | BTU | | | SOP | BUTANE | 0.115 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0107 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.26 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.41 | ‰ | | | SOP | DELTA 13C C2 | -30.31 | ‰ | | | SOP | DELTA 13C C3 | -25.19 | ‰ | | | SOP | DELTA D C1 | -240.5 | ‰ | | | SOP | ETHANE | 5.16 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.56 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.134 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0402 | MOL % | 0.0001 | | SOP | METHANE | 65.89 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 26.55 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.23 | MOL % | 0.01 | | SOP | PENTANE | 0.0117 | MOL % | 0.0001 | | SOP | PROPANE | 1.13 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.712 | RATIO_AIR | | |
Sample ID: 558191 Sample Date: 05/02/2017 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 558191 ISOTECH ID: 610348 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.44 | mg/L | 0.01 | | SOP | ETHANE | 4 | mg/L | 0.0002 | | SOP | METHANE | 25 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 15 | mg/L | 0.01 | | SOP | PROPANE | 1.2 | mg/L | 0.0002 | |
Sample ID: 558185 Sample Date: 05/02/2017 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 558185 Accutest ID: D93553-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 558187 Sample Date: 05/02/2017 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 558187 Accutest ID: D93552-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 260 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 700 | cfu/ml | 200 | | E200.7 | BORON | 0.247 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.07 | mg/L | 0.4 | | E200.7 | IRON | 0.0646 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.445 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0099 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.31 | mg/L | 1 | | E200.7 | SODIUM | 259 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0618 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0487 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.51 | mg/L | 0.1 | | E300.0 | CHLORIDE | 48.2 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 3.4 | mg/L | 1 | | E365.1 | PHOSPHORUS | ND | mg/L | 0.05 | U | FIELD | DISSOLVED OXYGEN, FIELD | 0.08 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -38 | mV | | | FIELD | PH, LAB | 8.2 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1020 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 16.6 | degrees C | | | FIELD | TURBIDITY | 1 | NTU | | | RSK175 | ETHANE | 0.98 | mg/L | 0.032 | | RSK175 | METHANE | 5.31 | mg/L | 0.016 | | RSK175 | PROPANE | 0.307 | mg/L | 0.044 | | SM1030 | CATION - ANION BALANCE | 3.24 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 431 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 33.8 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 465 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 985 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 643 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.54 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.158 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 606088 Sample Date: 05/02/2017 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 606088 ISOTECH ID: 610351 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.2 | ‰ | | | SOP | DELTA 18O H2O | -13.67 | ‰ | | | SOP | DELTA D H2O | -104.5 | ‰ | | |
Sample ID: 550427 Sample Date: 04/28/2016 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 550427 ISOTECH ID: 563936 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.492 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 783 | BTU | | | SOP | BUTANE | 0.142 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0127 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.27 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -58.04 | ‰ | | | SOP | DELTA 13C C2 | -29.93 | ‰ | | | SOP | DELTA 13C C3 | -25.23 | ‰ | | | SOP | DELTA D C1 | -243.8 | ‰ | | | SOP | ETHANE | 4.87 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.59 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.126 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0414 | MOL % | 0.0001 | | SOP | METHANE | 64.8 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 27.19 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.92 | MOL % | 0.01 | | SOP | PENTANE | 0.0163 | MOL % | 0.0001 | | SOP | PROPANE | 1.12 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.718 | RATIO_AIR | | |
Sample ID: 550428 Sample Date: 04/28/2016 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 550428 ISOTECH ID: 563936 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.49 | mg/L | 0.01 | | SOP | ETHANE | 3.9 | mg/L | 0.0002 | | SOP | METHANE | 26 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 17 | mg/L | 0.01 | | SOP | PROPANE | 1.2 | mg/L | 0.0003 | |
Sample ID: 550422 Sample Date: 04/28/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 550422 Accutest ID: D82193-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 550424 Sample Date: 04/28/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 550424 Accutest ID: D82192-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 74500 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1020 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.7 | SU | | | E170.1 | TEMPERATURE, FIELD | 15.22 | degrees C | | | E200.7 | BORON | 0.262 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.86 | mg/L | 0.4 | | E200.7 | IRON | 0.0739 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.465 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0094 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.11 | mg/L | 1 | | E200.7 | SODIUM | 226 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.056 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0454 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.48 | mg/L | 0.1 | | E300.0 | CHLORIDE | 46.1 | mg/L | 5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 2.3 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.09 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -47 | mV | | | FIELD | TURBIDITY | 1.2 | NTU | | | HACH | PHOSPHORUS | ND | mg/L | 0.01 | U | RSK175 | ETHANE | 1.52 | mg/L | 0.0016 | | RSK175 | METHANE | 8.57 | mg/L | 0.02 | | RSK175 | PROPANE | 0.509 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 4.26 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 442 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 34.4 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 477 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 820 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 588 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.69 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.212 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 607449 Sample Date: 04/28/2016 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 607449 ISOTECH ID: 563604 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.7 | ‰ | | | SOP | DELTA 18O H2O | -13.56 | ‰ | | | SOP | DELTA D H2O | -104.9 | ‰ | | |
Sample ID: 638682 Sample Date: 04/14/2022 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 638682 ISOTECH ID: 826147 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.723 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 591 | BTU | | | SOP | BUTANE | 0.0443 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0058 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.48 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -65.11 | ‰ | | | SOP | DELTA 13C C2 | -30.49 | ‰ | | | SOP | DELTA 13C C3 | -25.4 | ‰ | | | SOP | DELTA 13C iC4 | -27.3 | ‰ | | | SOP | DELTA 13C nC4 | -24.1 | ‰ | | | SOP | DELTA D C1 | -229 | ‰ | | | SOP | ETHANE | 1.85 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.76 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.043 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.013 | MOL % | 0.0001 | | SOP | METHANE | 53.82 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 38.48 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 4.16 | MOL % | 0.01 | | SOP | PENTANE | 0.0054 | MOL % | 0.0001 | | SOP | PROPANE | 0.375 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.761 | RATIO_AIR | | |
Sample ID: 638683 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 638683 ISOTECH ID: 826147 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.58 | mg/L | 0.02 | | SOP | ETHANE | 1.2 | mg/L | 0.0003 | | SOP | METHANE | 17 | mg/L | 0.0003 | | SOP | NITROGEN (N2) | 20 | mg/L | 0.02 | | SOP | PROPANE | 0.34 | mg/L | 0.0004 | |
Sample ID: 638676 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 638676 Accutest ID: DA43926-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 2 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 3 | U |
Sample ID: 638677 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 638677 Accutest ID: DA43924-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E300.0 | BROMIDE | 0.46 | mg/L | 0.1 | | E300.0 | CHLORIDE | 42.4 | mg/L | 13 | | E300.0 | FLUORIDE | 1.8 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.12 | U | E300.0 | NITRITE | ND | mg/L | 0.1 | U | E300.0 | SULFATE | ND | mg/L | 1 | U | E365.1 | PHOSPHORUS | 0.054 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -200 | mV | | | FIELD | pH, FIELD | 8.5 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1020 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 17.04 | degrees C | | | FIELD | TURBIDITY | 4.2 | NTU | | | RSK175 | ETHANE | 0.596 | mg/L | 0.08 | | RSK175 | METHANE | 7.43 | mg/L | 0.04 | | RSK175 | PROPANE | 0.179 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 8.7 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 410 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 40 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 450 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1010 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 603 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.85 | SU | | |
Sample ID: 638678 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 638678 Accutest ID: DA43924-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | E200.8 | BARIUM | 0.0417 | mg/L | 0.001 | | E200.8 | BORON | 0.253 | mg/L | 0.25 | | E200.8 | CALCIUM | 1.49 | mg/L | 0.25 | | E200.8 | IRON | ND | mg/L | 0.05 | U | E200.8 | MAGNESIUM | 0.349 | mg/L | 0.25 | | E200.8 | MANGANESE | 0.0038 | mg/L | 0.001 | | E200.8 | POTASSIUM | 0.964 | mg/L | 0.25 | | E200.8 | SELENIUM | ND | mg/L | 0.001 | U | E200.8 | SODIUM | 196 | mg/L | 13 | | E200.8 | STRONTIUM | 0.0541 | mg/L | 0.005 | |
Sample ID: 638679 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 638679 Accutest ID: DA43924-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.094 | U |
Sample ID: 638680 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 638680 Accutest ID: DA43924-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 2 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 3 | U |
Sample ID: 638681 Sample Date: 04/14/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 638681 ISOTECH ID: 826151 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.5 | ‰ | | | SOP | DELTA 18O H2O | -13.62 | ‰ | | | SOP | DELTA D H2O | -103.2 | ‰ | | |
Sample ID: 543738 Sample Date: 04/14/2015 Matrix: GAS Collection Point: Type: dom Lab: ISOTECHSample Results for Sample # 543738 ISOTECH ID: 504628 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.354 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 895 | BTU | | | SOP | BUTANE | 0.186 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0151 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.3 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.19 | ‰ | | | SOP | DELTA 13C C2 | -30.01 | ‰ | | | SOP | DELTA 13C C3 | -25.43 | ‰ | | | SOP | DELTA D C1 | -238.9 | ‰ | | | SOP | ETHANE | 7.01 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.58 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.165 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0482 | MOL % | 0.0001 | | SOP | METHANE | 70.84 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 18.87 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.72 | MOL % | 0.01 | | SOP | PENTANE | 0.0163 | MOL % | 0.0001 | | SOP | PROPANE | 1.48 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.697 | RATIO_AIR | | |
Sample ID: 543739 Sample Date: 04/14/2015 Matrix: WATER Collection Point: Type: dom Lab: ISOTECHSample Results for Sample # 543739 ISOTECH ID: 504628 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.38 | mg/L | 0.01 | | SOP | ETHANE | 6.1 | mg/L | 0.0002 | | SOP | METHANE | 31 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 13 | mg/L | 0.02 | | SOP | PROPANE | 1.8 | mg/L | 0.0003 | |
Sample ID: 543805 Sample Date: 04/14/2015 Matrix: WATER Collection Point: Type: SMP Lab: AccutestSample Results for Sample # 543805 Accutest ID: D69772-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 543817 Sample Date: 04/14/2015 Matrix: WATER Collection Point: Type: SMP Lab: AccutestSample Results for Sample # 543817 Accutest ID: D69770-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 700 | cfu/ml | 200 | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1070 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.7 | SU | | | E170.1 | TEMPERATURE, FIELD | 17.05 | degrees C | | | E200.7 | BORON | 0.274 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.02 | mg/L | 0.4 | | E200.7 | IRON | 0.119 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.534 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0139 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.19 | mg/L | 1 | | E200.7 | SODIUM | 253 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0638 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0473 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.57 | mg/L | 0.1 | | E300.0 | CHLORIDE | 50.6 | mg/L | 1 | | E300.0 | FLUORIDE | 2.2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | 0.0087 | mg/L | 0.008 | | E300.0 | SULFATE | 4.5 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | 36.6 | mV | | | FIELD | TURBIDITY | 0.47 | NTU | | | HACH | PHOSPHORUS | 0.074 | mg/L | 0.01 | | RSK175 | ETHANE | 2.25 | mg/L | 0.04 | | RSK175 | METHANE | 10 | mg/L | 0.02 | | RSK175 | PROPANE | 0.822 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 0.39 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 443 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 35.6 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 479 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 870 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 624 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.65 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.28 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 625302 Sample Date: 04/12/2021 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 625302 Accutest ID: DA33801-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 625303 Sample Date: 04/12/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 625303 Accutest ID: DA33800-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2200 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.7 | BORON | 0.243 | mg/L | 0.05 | | E200.7 | CALCIUM | 1.99 | mg/L | 0.4 | | E200.7 | IRON | 0.084 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.53 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0105 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.38 | mg/L | 1 | | E200.7 | SODIUM | 273 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0641 | mg/L | 0.005 | | E200.8 | BARIUM | 0.119 | mg/L | 0.004 | | E200.8 | SELENIUM | 0.0705 | mg/L | 0.0008 | | E300.0 | BROMIDE | 0.5 | mg/L | 0.1 | | E300.0 | CHLORIDE | 47.8 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.7 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 2 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.051 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -130 | mV | | | FIELD | pH, FIELD | 8.5 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1090 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 16.09 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.68 | mg/L | 0.08 | | RSK175 | METHANE | 8.41 | mg/L | 0.04 | | RSK175 | PROPANE | 0.494 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 5.8 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 428 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 35 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 463 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 845 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 611 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.84 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.163 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 625304 Sample Date: 04/12/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 625304 ISOTECH ID: 789559 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -10.8 | ‰ | | | SOP | DELTA 18O H2O | -13.69 | ‰ | | | SOP | DELTA D H2O | -103.2 | ‰ | | |
Sample ID: 625305 Sample Date: 04/12/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 625305 ISOTECH ID: 789563 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.48 | mg/L | 0.01 | | SOP | ARGON | 0.499 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 785 | BTU | | | SOP | BUTANE | 0.15 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0166 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.33 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -56.89 | ‰ | | | SOP | DELTA 13C C2 | -30.16 | ‰ | | | SOP | DELTA 13C C3 | -25.48 | ‰ | | | SOP | DELTA 13C iC4 | -28 | ‰ | | | SOP | Delta 13C iC5 | -26.8 | ‰ | | | SOP | DELTA 13C nC4 | -25.1 | ‰ | | | SOP | DELTA D C1 | -223.2 | ‰ | | | SOP | ETHANE | 4.2 | mg/L | 0.0002 | | SOP | ETHANE | 5.41 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.64 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.131 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0406 | MOL % | 0.0001 | | SOP | METHANE | 25 | mg/L | 0.0002 | | SOP | METHANE | 63.88 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 15 | mg/L | 0.02 | | SOP | NITROGEN (N2) | 25.16 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 3.2 | MOL % | 0.01 | | SOP | PENTANE | 0.0179 | MOL % | 0.0001 | | SOP | PROPANE | 1.16 | MOL % | 0.0001 | | SOP | PROPANE | 1.3 | mg/L | 0.0003 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.726 | RATIO_AIR | | |
Sample ID: 650531 Sample Date: 04/11/2023 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 650531 ISOTECH ID: 867271 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.768 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 614 | BTU | | | SOP | BUTANE | 0.056 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0074 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.38 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -60.02 | ‰ | | | SOP | DELTA 13C C2 | -30.17 | ‰ | | | SOP | DELTA 13C C3 | -25.2 | ‰ | | | SOP | DELTA 13C iC4 | -27.5 | ‰ | | | SOP | DELTA 13C nC4 | -24.4 | ‰ | | | SOP | DELTA D C1 | -233.2 | ‰ | | | SOP | ETHANE | 3.09 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.64 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0634 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0174 | MOL % | 0.0001 | | SOP | METHANE | 53.4 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 37.11 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 4.59 | MOL % | 0.01 | | SOP | PENTANE | 0.0055 | MOL % | 0.0001 | | SOP | PROPANE | 0.516 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.765 | RATIO_AIR | | |
Sample ID: 650532 Sample Date: 04/11/2023 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 650532 ISOTECH ID: 867271 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.68 | mg/L | 0.01 | | SOP | ETHANE | 2.2 | mg/L | 0.0002 | | SOP | METHANE | 19 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 20 | mg/L | 0.02 | | SOP | PROPANE | 0.52 | mg/L | 0.0003 | |
Sample ID: 650528 Sample Date: 04/11/2023 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 650528 Accutest ID: DA54668-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 650529 Sample Date: 04/11/2023 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 650529 Accutest ID: DA54667-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 13000 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 325 | cfu/ml | 200 | | E200.8 | BARIUM | 0.0555 | mg/L | 0.002 | | E200.8 | BORON | 0.241 | mg/L | 0.04 | | E200.8 | CALCIUM | 2.26 | mg/L | 0.4 | | E200.8 | IRON | 0.0859 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.627 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.0136 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.16 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 273 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0777 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.51 | mg/L | 0.5 | | E300.0 | CHLORIDE | 47.2 | mg/L | 5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.1 | | E300.0 | NITRATE | ND | mg/L | 0.1 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.14 | U | E300.0 | NITRITE | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 12.7 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.043 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.04 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | 13 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1120 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 16.2 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 0.933 | mg/L | 0.08 | | RSK175 | METHANE | 7.01 | mg/L | 0.04 | | RSK175 | PROPANE | 0.216 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 0.54 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 495 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 30 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 525 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1180 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 669 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.89 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0657 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 650530 Sample Date: 04/11/2023 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 650530 ISOTECH ID: 867287 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.1 | ‰ | | | SOP | DELTA 18O H2O | -13.71 | ‰ | | | SOP | DELTA D H2O | -104.9 | ‰ | | |
Sample ID: 659656 Sample Date: 04/01/2024 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 659656 ISOTECH ID: 917018 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.656 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 741 | BTU | | | SOP | BUTANE | 0.0633 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0126 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.47 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.94 | ‰ | | | SOP | DELTA 13C C2 | -30.14 | ‰ | | | SOP | DELTA 13C C3 | -25.26 | ‰ | | | SOP | DELTA 13C iC4 | -27.9 | ‰ | | | SOP | DELTA 13C nC4 | -24.3 | ‰ | | | SOP | DELTA D C1 | -227.4 | ‰ | | | SOP | ETHANE | 4.3 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.72 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.0025 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0598 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.016 | MOL % | 0.0001 | | SOP | METHANE | 63.59 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 29.97 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.29 | MOL % | 0.01 | | SOP | PENTANE | 0.0074 | MOL % | 0.0001 | | SOP | PROPANE | 0.567 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.718 | RATIO_AIR | | |
Sample ID: 659657 Sample Date: 04/01/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 659657 ISOTECH ID: 917018 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.49 | mg/L | 0.01 | | SOP | ETHANE | 2.6 | mg/L | 0.0002 | | SOP | METHANE | 19 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 14 | mg/L | 0.02 | | SOP | PROPANE | 0.48 | mg/L | 0.0003 | |
Sample ID: 659652 Sample Date: 04/01/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 659652 Accutest ID: DA63365-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 659653 Sample Date: 04/01/2024 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 659653 Accutest ID: DA63363-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 150 | cfu/ml | 25 | | BART | BACTERIA, IRON RELATED | 150 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0607 | mg/L | 0.002 | | E200.8 | BORON | 0.248 | mg/L | 0.04 | | E200.8 | CALCIUM | 2.66 | mg/L | 0.4 | | E200.8 | IRON | 0.061 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.75 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.0161 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.3 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 297 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0892 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.59 | mg/L | 0.1 | | E300.0 | CHLORIDE | 71.5 | mg/L | 5 | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | NITRITE | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 16.6 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.035 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.1 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -100 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1150 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 15.8 | degrees C | | | FIELD | TURBIDITY | 2 | NTU | | | RSK175 | ETHANE | 0.884 | mg/L | 0.08 | | RSK175 | METHANE | 5.85 | mg/L | 0.04 | | RSK175 | PROPANE | 0.148 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 2.3 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 535 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 30 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 565 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1230 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 640 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.96 | SU | | | SW8015 | TVPH - Gasoline Range Organics | 0.07 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 659654 Sample Date: 04/01/2024 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 659654 Accutest ID: DA63363-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.08 | U |
Sample ID: 617304 Sample Date: 04/01/2020 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 617304 ISOTECH ID: 759427 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.507 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 866 | BTU | | | SOP | BUTANE | 0.0641 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0062 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.59 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.3 | ‰ | | | SOP | DELTA 13C C2 | -30.22 | ‰ | | | SOP | DELTA 13C C3 | -24.7 | ‰ | | | SOP | DELTA D C1 | -236.7 | ‰ | | | SOP | ETHANE | 7 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.76 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0596 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0153 | MOL % | 0.0001 | | SOP | METHANE | 70.93 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 19.88 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.26 | MOL % | 0.01 | | SOP | PENTANE | 0.0058 | MOL % | 0.0001 | | SOP | PROPANE | 0.682 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.69 | RATIO_AIR | | |
Sample ID: 617305 Sample Date: 04/01/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 617305 ISOTECH ID: 759427 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.36 | mg/L | 0.01 | | SOP | ETHANE | 4.1 | mg/L | 0.0002 | | SOP | METHANE | 20 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 8.9 | mg/L | 0.02 | | SOP | PROPANE | 0.55 | mg/L | 0.0003 | |
Sample ID: 617301 Sample Date: 04/01/2020 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 617301 Accutest ID: DA25243-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 617302 Sample Date: 04/01/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 617302 Accutest ID: DA25242-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 6000 | cfu/ml | 200 | | E200.7 | BORON | 0.231 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.45 | mg/L | 0.4 | | E200.7 | IRON | 0.0223 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.687 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0164 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.23 | mg/L | 1 | | E200.7 | SODIUM | 262 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0741 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0603 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0012 | U | E300.0 | BROMIDE | 0.59 | mg/L | 0.5 | | E300.0 | CHLORIDE | 55 | mg/L | 5 | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.1 | | E300.0 | NITRATE | ND | mg/L | 0.1 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.14 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 5.2 | mg/L | 0.5 | | E365.1 | PHOSPHORUS | 0.043 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -240 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1150 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 15.96 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.09 | mg/L | 0.016 | | RSK175 | METHANE | 8.17 | mg/L | 0.04 | | RSK175 | PROPANE | 0.301 | mg/L | 0.022 | | SM1030 | CATION - ANION BALANCE | 0.57 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 478 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 19.5 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 497 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1110 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 693 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.69 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0762 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 617303 Sample Date: 04/01/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 617303 ISOTECH ID: 759424 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.9 | ‰ | | | SOP | DELTA 18O H2O | -13.72 | ‰ | | | SOP | DELTA D H2O | -105.2 | ‰ | | |
Sample ID: 566129 Sample Date: 03/15/2018 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 566129 ISOTECH ID: 655957 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.59 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 737 | BTU | | | SOP | BUTANE | 0.0802 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0068 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.36 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.09 | ‰ | | | SOP | DELTA 13C C2 | -30.17 | ‰ | | | SOP | DELTA 13C C3 | -24.36 | ‰ | | | SOP | DELTA D C1 | -244.6 | ‰ | | | SOP | ETHANE | 4.49 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.58 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.122 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0315 | MOL % | 0.0001 | | SOP | METHANE | 61.63 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 31.02 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.71 | MOL % | 0.01 | | SOP | PENTANE | 0.0078 | MOL % | 0.0001 | | SOP | PROPANE | 0.953 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.729 | RATIO_AIR | | |
Sample ID: 566130 Sample Date: 03/15/2018 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 566130 ISOTECH ID: 655957 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.57 | mg/L | 0.01 | | SOP | ETHANE | 3.5 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 18 | mg/L | 0.01 | | SOP | PROPANE | 1 | mg/L | 0.0003 | |
Sample ID: 566124 Sample Date: 03/15/2018 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 566124 Accutest ID: DA3554-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 566126 Sample Date: 03/15/2018 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 566126 Accutest ID: DA3553-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2300 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 359000 | cfu/ml | 200 | | E200.7 | BORON | 0.242 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.82 | mg/L | 0.4 | | E200.7 | IRON | 0.0745 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.66 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0127 | mg/L | 0.005 | | E200.7 | POTASSIUM | 2.18 | mg/L | 1 | | E200.7 | SODIUM | 273 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0787 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0599 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | ND | mg/L | 1 | U | E300.0 | CHLORIDE | 61.8 | mg/L | 10 | | E300.0 | FLUORIDE | 2.3 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.2 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.28 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.08 | U | E300.0 | SULFATE | 16.4 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.038 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.02 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -260 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1160 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 15.95 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1 | mg/L | 0.0016 | | RSK175 | METHANE | 5.78 | mg/L | 0.008 | | RSK175 | PROPANE | 0.284 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 0.94 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 485 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 29.3 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 514 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1130 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 699 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.76 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0899 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 605370 Sample Date: 03/15/2018 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 605370 ISOTECH ID: 655958 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.9 | ‰ | | | SOP | DELTA 18O H2O | -13.72 | ‰ | | | SOP | DELTA D H2O | -105.5 | ‰ | | |
Sample ID: 606617 Sample Date: 02/28/2019 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 606617 ISOTECH ID: 707016 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.61 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 786 | BTU | | | SOP | BUTANE | 0.0716 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0095 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.42 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -55.92 | ‰ | | | SOP | DELTA 13C C2 | -30.18 | ‰ | | | SOP | DELTA 13C C3 | -23.56 | ‰ | | | SOP | DELTA D C1 | -236.6 | ‰ | | | SOP | ETHANE | 5.24 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.62 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.0746 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0212 | MOL % | 0.0001 | | SOP | METHANE | 65.63 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 26.98 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.075 | MOL % | 0.01 | | SOP | PENTANE | 0.0082 | MOL % | 0.0001 | | SOP | PROPANE | 0.861 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.712 | RATIO_AIR | | |
Sample ID: 606618 Sample Date: 02/28/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 606618 ISOTECH ID: 707016 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.57 | mg/L | 0.01 | | SOP | ETHANE | 4 | mg/L | 0.0002 | | SOP | METHANE | 25 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 16 | mg/L | 0.02 | | SOP | PROPANE | 0.91 | mg/L | 0.0003 | |
Sample ID: 606614 Sample Date: 02/28/2019 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 606614 Accutest ID: DA13910-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 606615 Sample Date: 02/28/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 606615 Accutest ID: DA13909-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 2500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 27000 | cfu/ml | 200 | | E200.7 | BORON | 0.252 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.95 | mg/L | 0.4 | | E200.7 | IRON | 0.0739 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.766 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0156 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.63 | mg/L | 1 | | E200.7 | SODIUM | 263 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0823 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0568 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.61 | mg/L | 0.1 | | E300.0 | CHLORIDE | 54.7 | mg/L | 5 | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.06 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 15 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.038 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -230 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1180 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 14.41 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.89 | mg/L | 0.08 | | RSK175 | METHANE | 8.69 | mg/L | 0.04 | | RSK175 | PROPANE | 0.429 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.7 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 497 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 27.3 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 524 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1150 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 701 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.75 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0874 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 606616 Sample Date: 02/28/2019 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 606616 ISOTECH ID: 707012 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.9 | ‰ | | | SOP | DELTA 18O H2O | -13.7 | ‰ | | | SOP | DELTA D H2O | -104.4 | ‰ | | |
Sample ID: 555851 Sample Date: 02/02/2017 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 555851 ISOTECH ID: 597840 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.569 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 754 | BTU | | | SOP | BUTANE | 0.0727 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0068 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.36 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -58.03 | ‰ | | | SOP | DELTA 13C C2 | -30.39 | ‰ | | | SOP | DELTA 13C C3 | -24.55 | ‰ | | | SOP | DELTA D C1 | -240 | ‰ | | | SOP | ETHANE | 4.81 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.64 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.133 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0349 | MOL % | 0.0001 | | SOP | METHANE | 62.58 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 29.71 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.71 | MOL % | 0.01 | | SOP | PENTANE | 0.0065 | MOL % | 0.0001 | | SOP | PROPANE | 1.01 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.726 | RATIO_AIR | | |
Sample ID: 555852 Sample Date: 02/02/2017 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 555852 ISOTECH ID: 597840 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.54 | mg/L | 0.01 | | SOP | ETHANE | 3.8 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 18 | mg/L | 0.02 | | SOP | PROPANE | 1.1 | mg/L | 0.0003 | |
Sample ID: 555846 Sample Date: 02/02/2017 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 555846 Accutest ID: D90955-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 555848 Sample Date: 02/02/2017 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 555848 Accutest ID: D90954-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 700 | cfu/ml | 200 | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1120 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.7 | SU | | | E170.1 | TEMPERATURE, FIELD | 12.43 | degrees C | | | E200.7 | BORON | 0.236 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.16 | mg/L | 0.4 | | E200.7 | IRON | 0.091 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.626 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0128 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.28 | mg/L | 1 | | E200.7 | SODIUM | 266 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0751 | mg/L | 0.005 | | E200.8 | BARIUM | 0.055 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.066 | mg/L | 0.05 | | E300.0 | CHLORIDE | 52.7 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 7.1 | mg/L | 0.5 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.09 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -220 | mV | | | FIELD | TURBIDITY | 1.2 | NTU | | | HACH | PHOSPHORUS | 0.044 | mg/L | 0.01 | | RSK175 | ETHANE | 1.54 | mg/L | 0.0016 | | RSK175 | METHANE | 10 | mg/L | 0.02 | | RSK175 | PROPANE | 0.462 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.4 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 460 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 18.9 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 479 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 912 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 700 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.68 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.132 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 606087 Sample Date: 02/02/2017 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 606087 ISOTECH ID: 597841 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.5 | ‰ | | | SOP | DELTA 18O H2O | -13.67 | ‰ | | | SOP | DELTA D H2O | -103.8 | ‰ | | |
Sample ID: 548455 Sample Date: 01/28/2016 Matrix: GAS Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 548455 ISOTECH ID: 551675 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.415 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 852 | BTU | | | SOP | BUTANE | 0.0778 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0041 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.34 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -53.74 | ‰ | | | SOP | DELTA 13C C2 | -30.05 | ‰ | | | SOP | DELTA 13C C3 | -24.29 | ‰ | | | SOP | DELTA D C1 | -237.4 | ‰ | | | SOP | ETHANE | 6.23 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.53 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.162 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0334 | MOL % | 0.0001 | | SOP | METHANE | 68.93 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 22.18 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.31 | MOL % | 0.01 | | SOP | PENTANE | 0.0056 | MOL % | 0.0001 | | SOP | PROPANE | 1.31 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.701 | RATIO_AIR | | |
Sample ID: 548456 Sample Date: 01/28/2016 Matrix: WATER Collection Point: Dom Type: dom Lab: ISOTECHSample Results for Sample # 548456 ISOTECH ID: 551675 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.47 | mg/L | 0.01 | | SOP | ETHANE | 5.7 | mg/L | 0.0002 | | SOP | METHANE | 31 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 15 | mg/L | 0.01 | | SOP | PROPANE | 1.7 | mg/L | 0.0003 | |
Sample ID: 548458 Sample Date: 01/28/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 548458 Accutest ID: D79401-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 548452 Sample Date: 01/28/2016 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 548452 Accutest ID: D79400-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1170 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.7 | SU | | | E170.1 | TEMPERATURE, FIELD | 13.36 | degrees C | | | E200.7 | BORON | 0.271 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.7 | mg/L | 0.4 | | E200.7 | IRON | 0.0577 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.736 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0139 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.48 | mg/L | 1 | | E200.7 | SODIUM | 263 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0804 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0594 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.54 | mg/L | 0.5 | | E300.0 | CHLORIDE | 54.1 | mg/L | 5 | | E300.0 | FLUORIDE | 2.2 | mg/L | 1 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.06 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 15 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.02 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -170 | mV | | | FIELD | TURBIDITY | 0.62 | NTU | | | HACH | PHOSPHORUS | 0.043 | mg/L | 0.01 | | RSK175 | ETHANE | 2.23 | mg/L | 0.064 | | RSK175 | METHANE | 11.1 | mg/L | 0.032 | | RSK175 | PROPANE | 0.779 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 1.75 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 480 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 32.7 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 513 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1070 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 692 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.63 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.118 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 607448 Sample Date: 01/28/2016 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 607448 ISOTECH ID: 551577 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.2 | ‰ | | | SOP | DELTA 18O H2O | -13.76 | ‰ | | | SOP | DELTA D H2O | -104.3 | ‰ | | |
Sample ID: 666574 Sample Date: 01/27/2025 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 666574 ISOTECH ID: 955256 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.764 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 616 | BTU | | | SOP | BUTANE | 0.0174 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0032 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.41 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -59.25 | ‰ | | | SOP | DELTA 13C C2 | -30 | ‰ | | | SOP | DELTA 13C C3 | -23.9 | ‰ | | | SOP | DELTA 13C iC4 | -27.8 | ‰ | | | SOP | DELTA D C1 | -233.7 | ‰ | | | SOP | ETHANE | 3.15 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.65 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.0025 | ND | SOP | ISOBUTANE | 0.0611 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0131 | MOL % | 0.0001 | | SOP | METHANE | 54.22 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 39.62 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 1.44 | MOL % | 0.01 | | SOP | PENTANE | 0.0014 | MOL % | 0.0001 | | SOP | PROPANE | 0.302 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.756 | RATIO_AIR | | |
Sample ID: 666575 Sample Date: 01/27/2025 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 666575 ISOTECH ID: 955256 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.7 | mg/L | 0.01 | | SOP | ETHANE | 2.4 | mg/L | 0.0002 | | SOP | METHANE | 20 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 22 | mg/L | 0.02 | | SOP | PROPANE | 0.32 | mg/L | 0.0003 | |
Sample ID: 666571 Sample Date: 01/27/2025 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 666571 Accutest ID: DA70118-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 666572 Sample Date: 01/27/2025 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 666572 Accutest ID: DA70117-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0621 | mg/L | 0.002 | | E200.8 | BORON | 0.245 | mg/L | 0.04 | | E200.8 | CALCIUM | 2.93 | mg/L | 0.4 | | E200.8 | IRON | 0.0933 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.854 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.0195 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.18 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 297 | mg/L | 10 | | E200.8 | STRONTIUM | 0.0891 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.58 | mg/L | 0.25 | | E300.0 | CHLORIDE | 52.2 | mg/L | 2.5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.05 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.07 | U | E300.0 | NITRITE | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 20.5 | mg/L | 2.5 | | E365.1 | PHOSPHORUS | 0.045 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.09 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | pH, FIELD | 8.8 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1080 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 11.6 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 0.813 | mg/L | 0.0016 | | RSK175 | METHANE | 6.44 | mg/L | 0.04 | | RSK175 | PROPANE | 0.12 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 0.65 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 542 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 25 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 567 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1270 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 610 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.68 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.17 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 666573 Sample Date: 01/27/2025 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 666573 ISOTECH ID: 955065 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.9 | ‰ | | | SOP | DELTA 18O H2O | -13.56 | ‰ | | | SOP | DELTA D H2O | -104.3 | ‰ | | |
Sample ID: 542177 Sample Date: 01/20/2015 Matrix: GAS Collection Point: COM Type: dom Lab: ISOTECHSample Results for Sample # 542177 ISOTECH ID: 487110 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.417 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 850 | BTU | | | SOP | BUTANE | 0.137 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0088 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.31 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -55.52 | ‰ | | | SOP | DELTA 13C C2 | -30.07 | ‰ | | | SOP | DELTA 13C C3 | -25.14 | ‰ | | | SOP | DELTA D C1 | -240.5 | ‰ | | | SOP | ETHANE | 6.02 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.58 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | ISOBUTANE | 0.163 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0507 | MOL % | 0.0001 | | SOP | METHANE | 68.84 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 22.5 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.25 | MOL % | 0.01 | | SOP | PENTANE | 0.0056 | MOL % | 0.0001 | | SOP | PROPANE | 1.3 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.702 | RATIO_AIR | | |
Sample ID: 542178 Sample Date: 01/20/2015 Matrix: WATER Collection Point: COM Type: dom Lab: ISOTECHSample Results for Sample # 542178 ISOTECH ID: 487110 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ETHANE | 5.3 | mg/L | 0.0002 | | SOP | METHANE | 30 | mg/L | 0.0002 | | SOP | PROPANE | 1.6 | mg/L | 0.0003 | |
Sample ID: 542180 Sample Date: 01/20/2015 Matrix: WATER Collection Point: COM Type: SMP Lab: AccutestSample Results for Sample # 542180 Accutest ID: D66826-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | ND | cfu/ml | 25 | U | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 18000 | cfu/ml | 200 | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1110 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 8.8 | SU | | | E170.1 | TEMPERATURE, FIELD | 15.25 | degrees C | | | E200.7 | BORON | 0.266 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.4 | mg/L | 0.4 | | E200.7 | IRON | 0.0973 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.642 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0178 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.24 | mg/L | 1 | | E200.7 | SODIUM | 261 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0724 | mg/L | 0.005 | | E200.8 | BARIUM | 0.054 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E300.0 | BROMIDE | 0.56 | mg/L | 0.1 | | E300.0 | CHLORIDE | 51.3 | mg/L | 1 | | E300.0 | FLUORIDE | 2.2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 7.5 | mg/L | 1 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -250 | mV | | | FIELD | TURBIDITY | 0.27 | NTU | | | HACH | PHOSPHORUS | ND | mg/L | 0.01 | U | RSK175 | ETHANE | 2.1 | mg/L | 0.08 | | RSK175 | METHANE | 11.8 | mg/L | 0.04 | | RSK175 | PROPANE | 0.737 | mg/L | 0.0022 | | SM1030 | CATION - ANION BALANCE | 2.3 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 472 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 5 | U | SM2320B | TOTAL ALKALINITY AS CACO3 | 472 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 947 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 668 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 8.67 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0962 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 542182 Sample Date: 01/20/2015 Matrix: WATER Collection Point: COM Type: SMP Lab: AccutestSample Results for Sample # 542182 Accutest ID: D66831-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 623648 Sample Date: 01/14/2021 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 623648 ISOTECH ID: 781886 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.41 | mg/L | 0.01 | | SOP | ARGON | 0.527 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 841 | BTU | | | SOP | BUTANE | 0.0793 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0103 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.52 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.34 | ‰ | | | SOP | DELTA 13C C2 | -30.06 | ‰ | | | SOP | DELTA 13C C3 | -24.78 | ‰ | | | SOP | DELTA 13C iC4 | -27.6 | ‰ | | | SOP | DELTA 13C nC4 | -24.1 | ‰ | | | SOP | DELTA D C1 | -232.7 | ‰ | | | SOP | ETHANE | 4.2 | mg/L | 0.0002 | | SOP | ETHANE | 6.63 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.71 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0896 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0248 | MOL % | 0.0001 | | SOP | METHANE | 22 | mg/L | 0.0002 | | SOP | METHANE | 68.78 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 11 | mg/L | 0.02 | | SOP | NITROGEN (N2) | 22.51 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.1 | MOL % | 0.01 | | SOP | PENTANE | 0.009 | MOL % | 0.0001 | | SOP | PROPANE | 0.64 | mg/L | 0.0003 | | SOP | PROPANE | 0.722 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.699 | RATIO_AIR | | |
Sample ID: 623644 Sample Date: 01/14/2021 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 623644 Accutest ID: DA31872-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 623645 Sample Date: 01/14/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 623645 Accutest ID: DA31873-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 500 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E300.0 | BROMIDE | 0.63 | mg/L | 0.1 | | E300.0 | CHLORIDE | 59.9 | mg/L | 5 | | E300.0 | FLUORIDE | 2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.06 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.04 | U | E300.0 | SULFATE | 10.8 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.039 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.02 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -260 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1280 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 13.74 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.42 | mg/L | 0.016 | | RSK175 | METHANE | 9.59 | mg/L | 0.04 | | RSK175 | PROPANE | 0.386 | mg/L | 0.022 | | SM1030 | CATION - ANION BALANCE | 5.8 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 515 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 15 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 530 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1080 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 705 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.55 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0998 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 623646 Sample Date: 01/14/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 623646 Accutest ID: DA31873-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | E200.7 | BORON | 0.266 | mg/L | 0.1 | | E200.7 | CALCIUM | 3.29 | mg/L | 0.3 | | E200.7 | IRON | ND | mg/L | 0.1 | U | E200.7 | MAGNESIUM | 1.01 | mg/L | 0.1 | | E200.7 | MANGANESE | 0.0187 | mg/L | 0.01 | | E200.7 | POTASSIUM | 1.5 | mg/L | 0.5 | | E200.7 | SODIUM | 252 | mg/L | 0.5 | | E200.7 | STRONTIUM | 0.0887 | mg/L | 0.01 | | E200.8 | BARIUM | 0.0551 | mg/L | 0.005 | | E200.8 | SELENIUM | ND | mg/L | 0.005 | U |
Sample ID: 623647 Sample Date: 01/14/2021 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 623647 ISOTECH ID: 781882 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.2 | ‰ | | | SOP | DELTA 18O H2O | -13.67 | ‰ | | | SOP | DELTA D H2O | -104.4 | ‰ | | |
Sample ID: 614975 Sample Date: 01/13/2020 Matrix: GAS Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 614975 ISOTECH ID: 751284 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.473 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 875 | BTU | | | SOP | BUTANE | 0.0713 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.008 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.49 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.09 | ‰ | | | SOP | DELTA 13C C2 | -30.19 | ‰ | | | SOP | DELTA 13C C3 | -24 | ‰ | | | SOP | DELTA D C1 | -224.3 | ‰ | | | SOP | ETHANE | 6.93 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.7 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0723 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0192 | MOL % | 0.0001 | | SOP | METHANE | 71.44 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 19.58 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.062 | MOL % | 0.01 | | SOP | PENTANE | 0.0073 | MOL % | 0.0001 | | SOP | PROPANE | 0.844 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.688 | RATIO_AIR | | |
Sample ID: 614976 Sample Date: 01/13/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: ISOTECHSample Results for Sample # 614976 ISOTECH ID: 751284 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.39 | mg/L | 0.01 | | SOP | ETHANE | 4.7 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 10 | mg/L | 0.02 | | SOP | PROPANE | 0.79 | mg/L | 0.0003 | |
Sample ID: 614973 Sample Date: 01/13/2020 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 614973 Accutest ID: DA23413-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 614974 Sample Date: 01/13/2020 Matrix: WATER Collection Point: Dom Type: DOM Lab: AccutestSample Results for Sample # 614974 Accutest ID: DA23412-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 2500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 6000 | cfu/ml | 200 | | E200.7 | BORON | 0.245 | mg/L | 0.05 | | E200.7 | CALCIUM | 2.78 | mg/L | 0.4 | | E200.7 | IRON | 0.039 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 0.857 | mg/L | 0.2 | | E200.7 | MANGANESE | 0.0139 | mg/L | 0.005 | | E200.7 | POTASSIUM | 1.22 | mg/L | 1 | | E200.7 | SODIUM | 265 | mg/L | 0.4 | | E200.7 | STRONTIUM | 0.0815 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0558 | mg/L | 0.004 | | E200.8 | SELENIUM | ND | mg/L | 0.0012 | U | E300.0 | BROMIDE | 0.6 | mg/L | 0.1 | | E300.0 | CHLORIDE | 56.6 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2.2 | mg/L | 0.5 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 8 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.035 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.03 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -260 | mV | | | FIELD | pH, FIELD | 8.6 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1240 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 14.74 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.25 | mg/L | 0.016 | | RSK175 | METHANE | 8.68 | mg/L | 0.04 | | RSK175 | PROPANE | 0.394 | mg/L | 0.022 | | SM1030 | CATION - ANION BALANCE | 0.74 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 468 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 23.6 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 492 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1010 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 699 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.81 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.119 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 648625 Sample Date: 01/05/2023 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 648625 ISOTECH ID: 855316 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.712 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 635 | BTU | | | SOP | BUTANE | 0.0569 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0108 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.76 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -58.45 | ‰ | | | SOP | DELTA 13C C2 | -30.21 | ‰ | | | SOP | DELTA 13C C3 | -24.8 | ‰ | | | SOP | DELTA 13C iC4 | -27.8 | ‰ | | | SOP | DELTA 13C nC4 | -24 | ‰ | | | SOP | DELTA D C1 | -239.1 | ‰ | | | SOP | ETHANE | 3.67 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.75 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0593 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0172 | MOL % | 0.0001 | | SOP | METHANE | 54.49 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 37.13 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 2.61 | MOL % | 0.01 | | SOP | PENTANE | 0.0068 | MOL % | 0.0001 | | SOP | PROPANE | 0.479 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.76 | RATIO_AIR | | |
Sample ID: 648626 Sample Date: 01/05/2023 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 648626 ISOTECH ID: 855316 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.67 | mg/L | 0.02 | | SOP | ETHANE | 2.7 | mg/L | 0.0003 | | SOP | METHANE | 21 | mg/L | 0.0003 | | SOP | NITROGEN (N2) | 22 | mg/L | 0.02 | | SOP | PROPANE | 0.5 | mg/L | 0.0004 | |
Sample ID: 648622 Sample Date: 01/05/2023 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 648622 Accutest ID: DA52393-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 648623 Sample Date: 01/05/2023 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 648623 Accutest ID: DA52392-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 35000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | 1400 | cfu/ml | 200 | | E200.8 | BARIUM | 0.0682 | mg/L | 0.004 | | E200.8 | BORON | 0.256 | mg/L | 0.08 | | E200.8 | CALCIUM | 3.06 | mg/L | 0.8 | | E200.8 | IRON | 0.0856 | mg/L | 0.04 | | E200.8 | MAGNESIUM | 0.88 | mg/L | 0.2 | | E200.8 | MANGANESE | 0.0203 | mg/L | 0.002 | | E200.8 | POTASSIUM | 1.37 | mg/L | 0.4 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E200.8 | SODIUM | 274 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0976 | mg/L | 0.04 | | E300.0 | BROMIDE | 0.63 | mg/L | 0.1 | | E300.0 | CHLORIDE | 58.7 | mg/L | 13 | | E300.0 | FLUORIDE | 2.1 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.12 | U | E300.0 | NITRITE | ND | mg/L | 0.1 | U | E300.0 | SULFATE | 17.6 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.033 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.01 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -230 | mV | | | FIELD | pH, FIELD | 8.7 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1210 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 13.27 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.01 | mg/L | 0.08 | | RSK175 | METHANE | 6.2 | mg/L | 0.04 | | RSK175 | PROPANE | 0.179 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 7.4 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 570 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 30 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 600 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1200 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 921 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.77 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.2 | U | SW8015 | TVPH - Gasoline Range Organics | 0.0782 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 648624 Sample Date: 01/05/2023 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 648624 ISOTECH ID: 855243 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12 | ‰ | | | SOP | DELTA 18O H2O | -13.78 | ‰ | | | SOP | DELTA D H2O | -105 | ‰ | | |
Sample ID: 634537 Sample Date: 01/05/2022 Matrix: GAS Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 634537 ISOTECH ID: 813789 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.532 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 665 | BTU | | | SOP | BUTANE | 0.0667 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.0086 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.33 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -54.15 | ‰ | | | SOP | DELTA 13C C2 | -30.18 | ‰ | | | SOP | DELTA 13C C3 | -24.55 | ‰ | | | SOP | DELTA 13C iC4 | -27.6 | ‰ | | | SOP | DELTA 13C nC4 | -24.4 | ‰ | | | SOP | DELTA D C1 | -227.6 | ‰ | | | SOP | ETHANE | 5.13 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.56 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0642 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0177 | MOL % | 0.0001 | | SOP | METHANE | 54.62 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 33.75 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 4.87 | MOL % | 0.01 | | SOP | PENTANE | 0.0075 | MOL % | 0.0001 | | SOP | PROPANE | 0.599 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.761 | RATIO_AIR | | |
Sample ID: 634538 Sample Date: 01/05/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 634538 ISOTECH ID: 813789 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.56 | mg/L | 0.01 | | SOP | ETHANE | 4.5 | mg/L | 0.0002 | | SOP | METHANE | 23 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 22 | mg/L | 0.01 | | SOP | PROPANE | 0.72 | mg/L | 0.0003 | |
Sample ID: 634534 Sample Date: 01/05/2022 Matrix: WATER Collection Point: Dom Type: TB Lab: AccutestSample Results for Sample # 634534 Accutest ID: DA40674-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 634535 Sample Date: 01/05/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: AccutestSample Results for Sample # 634535 Accutest ID: DA40675-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 25 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.0738 | mg/L | 0.004 | | E200.8 | BORON | 0.231 | mg/L | 0.08 | | E200.8 | CALCIUM | 2.82 | mg/L | 0.8 | | E200.8 | IRON | 0.0613 | mg/L | 0.04 | | E200.8 | MAGNESIUM | 0.851 | mg/L | 0.2 | | E200.8 | MANGANESE | 0.0182 | mg/L | 0.002 | | E200.8 | POTASSIUM | 1.31 | mg/L | 0.4 | | E200.8 | SELENIUM | ND | mg/L | 0.0008 | U | E200.8 | SODIUM | 244 | mg/L | 5 | | E200.8 | STRONTIUM | 0.0961 | mg/L | 0.04 | | E300.0 | BROMIDE | 0.63 | mg/L | 0.25 | | E300.0 | CHLORIDE | 60.2 | mg/L | 2.5 | | E300.0 | FLUORIDE | 2.2 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.04 | U | E300.0 | NITRITE | ND | mg/L | 0.02 | U | E300.0 | SULFATE | 13 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.037 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -200 | mV | | | FIELD | pH, FIELD | 8.4 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1130 | UMHOS/CM | 0.5 | | FIELD | TEMPERATURE, FIELD | 12.86 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 2.1 | mg/L | 0.016 | | RSK175 | METHANE | 8.51 | mg/L | 0.04 | | RSK175 | PROPANE | 0.385 | mg/L | 0.022 | | SM1030 | CATION - ANION BALANCE | 3.5 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 478 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 25 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 503 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 991 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 724 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.81 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | 0.111 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 634536 Sample Date: 01/05/2022 Matrix: WATER Collection Point: Dom Type: GW Lab: ISOTECHSample Results for Sample # 634536 ISOTECH ID: 813788 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -12.2 | ‰ | | | SOP | DELTA 18O H2O | -13.8 | ‰ | | | SOP | DELTA D H2O | -105.1 | ‰ | | |
Sample ID: 657503 Sample Date: 01/04/2024 Matrix: GAS Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 657503 ISOTECH ID: 905608 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.626 | MOL % | 0.005 | | SOP | BRITISH THERMAL UNITS | 736 | BTU | | | SOP | BUTANE | 0.0557 | MOL % | 0.0001 | | SOP | C6+ (hexanes +) | 0.008 | MOL % | 0.0001 | | SOP | CARBON DIOXIDE | 0.44 | MOL % | 0.005 | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | SOP | DELTA 13C C1 | -57.03 | ‰ | | | SOP | DELTA 13C C2 | -30.02 | ‰ | | | SOP | DELTA 13C C3 | -25 | ‰ | | | SOP | DELTA 13C iC4 | -27.7 | ‰ | | | SOP | DELTA 13C nC4 | -24.4 | ‰ | | | SOP | DELTA D C1 | -236.3 | ‰ | | | SOP | ETHANE | 4.56 | MOL % | 0.0001 | | SOP | ETHENE | ND | MOL % | 0.0001 | ND | SOP | HELIUM DILUTION FACTOR | 0.66 | NA | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | SOP | ISOBUTANE | 0.0566 | MOL % | 0.0001 | | SOP | ISOPENTANE | 0.0148 | MOL % | 0.0001 | | SOP | METHANE | 62.98 | MOL % | 0.0002 | | SOP | NITROGEN (N2) | 30.45 | MOL % | 0.01 | | SOP | OXYGEN (O2) | 0.32 | MOL % | 0.01 | | SOP | PENTANE | 0.0062 | MOL % | 0.0001 | | SOP | PROPANE | 0.482 | MOL % | 0.0001 | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | SOP | SPECIFIC GRAVITY | 0.72 | RATIO_AIR | | |
Sample ID: 657504 Sample Date: 01/04/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 657504 ISOTECH ID: 905608 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | ARGON | 0.58 | mg/L | 0.01 | | SOP | ETHANE | 3.4 | mg/L | 0.0002 | | SOP | METHANE | 24 | mg/L | 0.0002 | | SOP | NITROGEN (N2) | 18 | mg/L | 0.02 | | SOP | PROPANE | 0.51 | mg/L | 0.0003 | |
Sample ID: 657505 Sample Date: 01/04/2024 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 657505 Accutest ID: DA61115-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 2200 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | ND | cfu/ml | 500 | U | BART | BACTERIA, SULFATE REDUCING | ND | cfu/ml | 200 | U | E200.8 | BARIUM | 0.063 | mg/L | 0.002 | | E200.8 | BORON | 0.228 | mg/L | 0.04 | | E200.8 | CALCIUM | 2.75 | mg/L | 0.4 | | E200.8 | IRON | 0.0659 | mg/L | 0.02 | | E200.8 | MAGNESIUM | 0.82 | mg/L | 0.1 | | E200.8 | MANGANESE | 0.0145 | mg/L | 0.001 | | E200.8 | POTASSIUM | 1.34 | mg/L | 0.2 | | E200.8 | SELENIUM | ND | mg/L | 0.0004 | U | E200.8 | SODIUM | 289 | mg/L | 5 | | E200.8 | STRONTIUM | 0.089 | mg/L | 0.02 | | E300.0 | BROMIDE | 0.57 | mg/L | 0.5 | | E300.0 | CHLORIDE | 52.3 | mg/L | 5 | | E300.0 | FLUORIDE | 1.9 | mg/L | 0.2 | | E300.0 | NITRATE | ND | mg/L | 0.02 | U | E300.0 | NITRATE/NITRITE AS N | ND | mg/L | 0.028 | U | E300.0 | NITRITE | ND | mg/L | 0.008 | U | E300.0 | SULFATE | 16 | mg/L | 1 | | E365.1 | PHOSPHORUS | 0.037 | mg/L | 0.01 | | FIELD | DISSOLVED OXYGEN, FIELD | 0.1 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | -40 | mV | | | FIELD | pH, FIELD | 8.8 | SU | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 1110 | umhos/cm | 0.5 | | FIELD | TEMPERATURE, FIELD | 13 | degrees C | | | FIELD | TURBIDITY | 0.02 | NTU | | | RSK175 | ETHANE | 1.32 | mg/L | 0.08 | | RSK175 | METHANE | 7.45 | mg/L | 0.04 | | RSK175 | PROPANE | 0.21 | mg/L | 0.11 | | SM1030 | CATION - ANION BALANCE | 0.76 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 525 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 30 | mg/L | 5 | | SM2320B | TOTAL ALKALINITY AS CACO3 | 555 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1200 | umhos/cm | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 668 | mg/L | 10 | | SM4500-H+ B | pH, FIELD | 8.75 | SU | | | SW8015 | TVPH - Gasoline Range Organics | 0.0783 | mg/L | 0.05 | | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 657500 Sample Date: 01/04/2024 Matrix: WATER Collection Point: TB Type: TB Lab: AccutestSample Results for Sample # 657500 Accutest ID: DA61116-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 657501 Sample Date: 01/04/2024 Matrix: WATER Collection Point: COM Type: GW Lab: AccutestSample Results for Sample # 657501 Accutest ID: DA61115-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.097 | U |
Sample ID: 657502 Sample Date: 01/04/2024 Matrix: WATER Collection Point: COM Type: GW Lab: ISOTECHSample Results for Sample # 657502 ISOTECH ID: 905607 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SOP | DELTA 13C DIC | -11.9 | ‰ | | | SOP | DELTA 18O H2O | -13.68 | ‰ | | | SOP | DELTA D H2O | -103.5 | ‰ | | |
|
|