Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#753802 Information View DocsDoc View GISGIS
Sample Site ID753802
FacilityTypeDOMProj Number
CountyWELD - 123LocationNWSE 33 3N65W
Elevation4810Lat/Long40.181631/-104.666558
DWR Receipt #0532433WellDepth420
 
Related Facility/Well
API Number: 05- - Well Name:No Facility 1
Well Status:CLOperator Name:UNKNOWN
Location:      

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   540847     Sample Date:  12/02/2014     Matrix:  GAS     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 540847    ISOTECH ID: 475872
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.641MOL %0.005
SOPBRITISH THERMAL UNITS630BTU
SOPBUTANENDMOL %0.0001ND
SOPC6+ (hexanes +)NDMOL %0.0001ND
SOPCARBON DIOXIDE0.45MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-73.22
SOPDELTA 13C C2-47.9
SOPDELTA D C1-265.1
SOPETHANE0.0765MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHELIUM DILUTION FACTOR0.67NA
SOPHYDROGENNDMOL %0.01ND
SOPISOBUTANENDMOL %0.0001ND
SOPISOPENTANENDMOL %0.0001ND
SOPMETHANE62.01MOL %0.0002
SOPNITROGEN (N2)35.93MOL %0.01
SOPOXYGEN (O2)0.89MOL %0.01
SOPPENTANENDMOL %0.0001ND
SOPPROPANENDMOL %0.0001ND
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.717RATIO_AIR

 Sample ID:   540842     Sample Date:  12/02/2014     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 540842    Accutest ID: D65179-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L2U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L3U

 Sample ID:   540848     Sample Date:  12/02/2014     Matrix:  WATER     Collection Point:  Dom     Type:  dom     Lab:  ISOTECH

Sample Results for Sample # 540848    ISOTECH ID: 475872
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPETHANE0.047mg/L0.0002
SOPMETHANE19mg/L0.0002
SOPPROPANENDmg/L0.0003ND

 Sample ID:   540844     Sample Date:  12/02/2014     Matrix:  WATER     Collection Point:  Dom     Type:  SMP     Lab:  Accutest

Sample Results for Sample # 540844    Accutest ID: D65178-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
BARTBACTERIA, IRON RELATEDNDcfu/ml25U
BARTBACTERIA, SLIME FORMING66500cfu/ml500
BARTBACTERIA, SULFATE REDUCING700cfu/ml200
E120.1SPECIFIC CONDUCTIVITY, FIELD1020UMHOS/CM0.5
E150.1PH, LAB8.6SU
E170.1TEMPERATURE, FIELD18.22degrees C
E200.7BORON0.311mg/L0.05
E200.7CALCIUM2mg/L0.4
E200.7IRONNDmg/L0.01U
E200.7MAGNESIUM0.486mg/L0.2
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUMNDmg/L1U
E200.7SODIUM235mg/L0.4
E200.7STRONTIUM0.0632mg/L0.005
E200.8BARIUM0.0449mg/L0.004
E200.8SELENIUMNDmg/L0.0008U
E300.0BROMIDE0.57mg/L0.1
E300.0CHLORIDE57.5mg/L1
E300.0FLUORIDE2.3mg/L0.2
E300.0NITRATENDmg/L0.02U
E300.0NITRATE/NITRITE AS NNDmg/L0.028U
E300.0Nitrite as NO2NDmg/L0.008U
E300.0SULFATENDmg/L1U
E360.1DISSOLVED OXYGEN, FIELD0.02mg/L
FIELDOXIDATION REDUCTION POTENTIAL-190mV
FIELDTURBIDITY0.46NTU
HACHPHOSPHORUS0.027mg/L0.01
RSK175ETHANE0.0196mg/L0.0016
RSK175METHANE6.43mg/L0.016
RSK175PROPANENDmg/L0.0022U
SM1030CATION - ANION BALANCE2.7%
SM2320BBICARBONATE ALKALINITY as CACO3467mg/L5
SM2320BCARBONATE ALKALINITY AS CACO313.6mg/L5
SM2320BTOTAL ALKALINITY AS CACO3481mg/L5
SM2510BSPECIFIC CONDUCTIVITY854UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS598mg/L10
SM4500-H+ BPH, LAB8.59SU
SW8015TEPH DIESEL RANGE ORGANICSNDmg/L0.19U
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L2U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L3U