Sample ID: 544703 Sample Date: 7/20/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 544703 Accutest ID: D73028-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | 0.25 | ug/L | 1 | J | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 544705 Sample Date: 7/20/2015 Matrix: WATER Collection Point: Dom Type: SMP Lab: AccutestSample Results for Sample # 544705 Accutest ID: D73030-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 9000 | cfu/ml | 25 | | BART | BACTERIA, SLIME FORMING | 66500 | cfu/ml | 500 | | BART | BACTERIA, SULFATE REDUCING | 18000 | cfu/ml | 200 | | E120.1 | SPECIFIC CONDUCTIVITY, FIELD | 1970 | UMHOS/CM | 0.5 | | E150.1 | PH, LAB | 7.3 | SU | | | E170.1 | TEMPERATURE, FIELD | 15.91 | degrees C | | | E200.7 | BORON | 0.329 | mg/L | 0.05 | | E200.7 | CALCIUM | 107 | mg/L | 0.4 | | E200.7 | IRON | 0.0129 | mg/L | 0.01 | | E200.7 | MAGNESIUM | 80 | mg/L | 0.2 | | E200.7 | MANGANESE | ND | mg/L | 0.005 | U | E200.7 | POTASSIUM | 2.76 | mg/L | 1 | | E200.7 | SODIUM | 226 | mg/L | 0.4 | | E200.7 | STRONTIUM | 2.15 | mg/L | 0.005 | | E200.8 | BARIUM | 0.0264 | mg/L | 0.004 | | E200.8 | SELENIUM | 0.0021 | mg/L | 0.0008 | | E300.0 | BROMIDE | 0.4 | mg/L | 0.25 | | E300.0 | CHLORIDE | 137 | mg/L | 10 | | E300.0 | FLUORIDE | 1.7 | mg/L | 0.5 | | E300.0 | NITRATE | 20.5 | mg/L | 0.5 | | E300.0 | NITRATE/NITRITE AS N | 20.5 | mg/L | 0.58 | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.08 | U | E300.0 | SULFATE | 451 | mg/L | 10 | | E360.1 | DISSOLVED OXYGEN, FIELD | 0.16 | mg/L | | | FIELD | OXIDATION REDUCTION POTENTIAL | 84.2 | mV | | | FIELD | TURBIDITY | 0.69 | NTU | | | HACH | PHOSPHORUS | 0.034 | mg/L | 0.01 | | RSK175 | ETHANE | ND | mg/L | 0.0016 | U | RSK175 | METHANE | ND | mg/L | 0.0008 | U | RSK175 | PROPANE | ND | mg/L | 0.0022 | U | SM1030 | CATION - ANION BALANCE | 0.84 | % | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | 374 | mg/L | 5 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 5 | U | SM2320B | TOTAL ALKALINITY AS CACO3 | 374 | mg/L | 5 | | SM2510B | SPECIFIC CONDUCTIVITY | 1670 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 1360 | mg/L | 10 | | SM4500-H+ B | PH, LAB | 7.44 | SU | | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.19 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 0.5 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 536475 Sample Date: 12/12/2013 Matrix: WATER Collection Point: Stock Type: Dom Lab: ALS Lab Group (formerly Paragon)Sample Results for Sample # 536475 ALS Lab Group (formerly Paragon) ID: 1312142-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 536477 Sample Date: 12/12/2013 Matrix: WATER Collection Point: Stock Type: Dom Lab: ALS Lab Group (formerly Paragon)Sample Results for Sample # 536477 ALS Lab Group (formerly Paragon) ID: 1312141-1 | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | BART | BACTERIA, IRON RELATED | 1 | NU | 1 | Prsnt | BART | BACTERIA, SLIME FORMING | 1 | NU | 1 | Prsnt | BART | BACTERIA, SULFATE REDUCING | 1 | NU | 1 | Prsnt | E200.8 | BARIUM | 34 | ug/L | 1 | | E200.8 | BORON | 270 | ug/L | 50 | | E200.8 | CALCIUM | 150000 | ug/L | 1000 | | E200.8 | IRON | ND | ug/L | 100 | U | E200.8 | MAGNESIUM | 100000 | ug/L | 100 | | E200.8 | MANGANESE | 110 | ug/L | 2 | | E200.8 | POTASSIUM | 3500 | ug/L | 1000 | | E200.8 | SELENIUM | 3.3 | ug/L | 1 | | E200.8 | SODIUM | 260000 | ug/L | 1000 | | E200.8 | STRONTIUM | 2900 | ug/L | 1 | | E300.0 | BROMIDE | 0.56 | mg/L | 0.4 | | E300.0 | CHLORIDE | 170 | mg/L | 4 | | E300.0 | FLUORIDE | 1.5 | mg/L | 0.2 | | E300.0 | NITRATE AS N | 25 | mg/L | 0.4 | | E300.0 | NITRATE/NITRITE AS N | 25 | mg/L | 0.1 | | E300.0 | NITRITE AS N | ND | mg/L | 0.2 | U | E300.0 | SULFATE | 610 | mg/L | 20 | | E365.2 | PHOSPHORUS | 0.059 | mg/L | 0.05 | | RSK175 | ETHANE | ND | ug/L | 2 | U | RSK175 | METHANE | ND | ug/L | 1 | U | RSK175 | PROPANE | ND | ug/L | 1 | U | SM2320B | BICARBONATE ALKALINITY as CACO3 | 450 | mg/L | 20 | | SM2320B | CARBONATE ALKALINITY AS CACO3 | ND | mg/L | 20 | U | SM2320B | TOTAL ALKALINITY AS CACO3 | 450 | mg/L | 20 | | SM2510B | SPECIFIC CONDUCTIVITY | 2380 | UMHOS/CM | 1 | | SM2540C | TOTAL DISSOLVED SOLIDS | 1700 | mg/L | 20 | | SM4500-H+ B | PH, LAB | 7.52 | SU | 0.1 | | SW8015 | TEPH DIESEL RANGE ORGANICS | ND | mg/L | 0.48 | U | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | SW8260 | BENZENE | ND | ug/L | 1 | U | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | SW8260 | o-XYLENE | ND | ug/L | 1 | U | SW8260 | TOLUENE | ND | ug/L | 1 | U | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|