LOCATION440092NGL MAJOR FACILITY
C5
NGL WATER SOLUTIONS DJ LLC
10373
AC
6/19/2018
WATTENBERG
90750
WELD  123
SWSW 29 2N64W 6
440092View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
OGLAForm: (02A )
400706275
11/12/2014
Operator shall provide notice to COGCC 48 hours prior to commencing construction of this Oil and Gas Location via Form 42.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
PlanningForm: (02A )
400706275
11/21/2014
This UIC Facility is for the separation of hydrocarbons and waste, the separated produced water shall be filtered prior to injection. Facility will serve 2 nearby wells.
Traffic controlForm: (02A )
400706275
11/21/2014
Access road: The access road will be constructed to accommodate local emergency vehicles. This road will be maintained for access at all times.
General HousekeepingForm: (02A )
400706275
11/21/2014
Fencing requirements. A permanent fencing plan will be reviewed by the surface owner, & the applicant.
General HousekeepingForm: (02A )
400706275
11/21/2014
Removal of surface trash. All trash, debris and material not intrinsic to the operation of a UIC Facility shall be removed and legally disposed of as is applicable.
Material Handling and Spill PreventionForm: (02A )
400706275
11/21/2014
Leak Detection Plan. Pumper will visit the location daily and visually inspect all tanks and fittings for leaks. Additionally, monthly documented SPCCP inspections are conducted pursuant to 40 CFR §112.
Material Handling and Spill PreventionForm: (02A )
400706275
11/21/2014
Berm construction. Tank berms shall be constructed of steel rings with a synthetic or engineered liner and designed to contain 150% of the capacity of the largest tank. All berms will be visually checked periodically to ensure proper working condition.
Material Handling and Spill PreventionForm: (02A )
400706275
11/21/2014
Load-lines. All load-lines shall be bull-plugged or capped.
Material Handling and Spill PreventionForm: (02A )
400706275
11/21/2014
Tank specifications. Tanks will be designed, constructed and maintained in accordance with NFPA Code 30. The tanks are visually inspected once a day for issues, and recorded inspections are conducted once a month.
Odor mitigationForm: (02A )
400706275
11/21/2014
Per Rule 805: Oil & gas facilities and equipment shall be operated in such a manner that odors and dust do not constitute a nuisance or hazard to public welfare.