Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION424424Federal
2-6H (PL35NW)
QB ENERGY OPERATING LLC
10844
AC
7/21/2012
PICEANCE HORIZONTAL NIOBRARA
68810
MESA  077
SENW 35 9S94W 6
424424View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
OGLAForm: (02A)
400170489
06/11/2011
Operator must implement best management practices to contain any unintentional release of fluids, including any fluids conveyed via temporary/permanent surface pipelines.
OGLAForm: (02A)
400170489
06/11/2011
A closed loop system (which operator has indicated on the Form 2A - Section 6. Construction) must be implemented during drilling.
OGLAForm: (02A)
400170489
06/11/2011
Operator must ensure secondary containment for any volume of fluids contained at well site during drilling and completion operations; including, but not limited to, construction of a berm or diversion dike, diversion/collection trenches within and/or outside of berms/dikes, site grading, or other comparable measures (i.e., best management practices (BMPs) associated with stormwater management) sufficiently protective of nearby surface water. Any berm constructed at the well pad location will be stabilized, inspected at regular intervals (at least every 14 days), and maintained in good condition.
OGLAForm: (02A)
400170489
06/11/2011
If fracing operations occur, flowback and stimulation fluids must be sent to tanks and/or filters before the fluids can be placed into any pipeline or pit. The flowback and stimulation fluid tanks and/or filters must be placed on the well pad in an area with additional downgradient perimeter berming. The area where flowback fluids will be stored/reused must be constructed to be sufficiently impervious to contain any spilled or released material.
OGLAForm: (02A)
400170489
06/11/2011
The access road will be constructed as to not allow any sediment to migrate from the access road to the nearby surface water or any drainages leading to surface water.
OGLAForm: (02A)
400170489
06/11/2011
Berms or other containment devices shall be constructed to be sufficiently impervious to contain any spilled or released material around crude oil, condensate, and produced water storage tanks.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Site SpecificForm: (02A )
400170489
7/23/2011
This location falls on both fee and federal surface with the SHL and BHL located on fed surface and a federal Lease. All wildlife stipulations and best managemnt pratices that apply, are applicable and that have been agreed to with the surface owner and the BLM as outlined in our 12 Point Surface Use Plan Of Operations as approved by the BLM and any Conditions of Approval placed on our approved APDs will be followed.