Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION335991SCHOOL POINT OM K15 696
QB ENERGY OPERATING LLC
10844
AC
10/1/2025
GRAND VALLEY
31290
GARFIELD  045
NESW 15 6S96W 6
335991View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EnvironmentalForm: (04)
400480043
10/02/2013
Before backfilling the pit, statistically representative DISCRETE samples of walls/bottom of the pit will be collected and sampled for TPH and PAHs. Representative discrete confirmation samples will be collected from the landfarmed soil for TPH, PAHs and SAR, pH, Arsenic. Arsenic background samples from nearby native soil (upgradient and cross-gradient of the pad) will be collected to compare arsenic background concentrations with impacted soil arsenic concentrations. A form 04, Notice of Completion will be submitted when pit and landfarmed material are in compliance with Table 910-1 and arsenic concentrations are below or at the max background concentration + 10%.
PermitForm: (04)
401246464
03/31/2017
The operator-of-record of this location is subject to the September 1, 2017 extended deadline granted by this variance to comply with the March 1, 2017 requirements of the COGCC Notice to Operators: Procedure for Preset Conductors (rev October 6, 2016) to have performed one of the following options: (1) plug the conductors and perform reclamation, (2) request to keep the conductors and provide additional financial assurance, or (3) submit a Rule 502.b variance for an alternative plan.
EnvironmentalForm: (04)
403937617
10/02/2024
Based on review of information presented it appears that no further action is necessary at this time, and ECMC approves this request for informational purposes. However, should future conditions at the site indicate contaminant concentrations in soils exceeding ECMC standards or if surface and/or ground water is found to be impacted, then further investigation and/or remediation activities will be required at the site. In addition, the non-working surface area disturbed by the remediation activity shall be reclaimed in accordance with the 1000 Series Reclamation Rules including the establishment of vegetative cover on non-cropland and successful growth on cropland. Landowner must approve reclamation of cropland.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
General HousekeepingForm: (04 )
400916227
10/23/2015
Although, Field Inspection Report #671000220 from 8/20/2015 was 'Satisfactory' and no follow up inspection was required, there was an Inspector Comment and picture attachment regarding the removal of piping on site that should be removed. The pipe was moved off-site on 8/20/2015