Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
UIC DISPOSAL159961RAZOR 26J-2633L SWD
TALLGRASS WATER WESTERN LLC
10608
AC
7/2/2015
DJ HORIZONTAL NIOBRARA
16950
WELD  123
NWSE 26 10N58W 6
433131View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
UICForm: (31)
2493423
07/02/2015
Initial maximum daily injection rate limited to 10,000 bbl/day. Operator must request increase above that. Request will be evaluated based on existing daily injection rate and seismic activity within 2.5 miles of the injection well.
UICForm: (31)
2493423
07/02/2015
Operator is required to install a seismometer at a location to be determined by the operator and COGCC from which seismic activity in the vicinity of the injection well can be monitored. The operator will be responsible for maintenance of the seismometer. Data gathered by the seismometer will be made available to one or more third parties (such as the USGS, CU-Boulder, CSM, or CSU) for analysis.
UICForm: (31)
2493423
07/02/2015
A water analysis to include TDS, major cations, and major anions is required 1- year after initial injection and from then on at 5-year intervals. Water analyses should be submitted via Sundry Notice and in Electronic Data Deliverable (EDD) Format.
UICForm: (04)
403286807
02/07/2023
Total permitted injection volume is hereby raised to 40,133,012 bbls. Injection volume may not be increased further per Rule 803.f.(4).
UICForm: (04)
403286807
02/07/2023
Maximum permitted surface injection pressure and maximum injection rate remain unchanged.
 
COGIS - Best Management Practice Results