| UIC | Form: (31) 2493423 07/02/2015 | Initial maximum daily injection rate limited to 10,000 bbl/day. Operator must request increase above that. Request will be evaluated based on existing daily injection rate and seismic activity within 2.5 miles of the injection well. |
| UIC | Form: (31) 2493423 07/02/2015 | Operator is required to install a seismometer at a location to be determined by the operator and COGCC from which seismic activity in the vicinity of the injection well can be monitored. The operator will be responsible for maintenance of the seismometer. Data gathered by the seismometer will be made available to one or more third parties (such as the USGS, CU-Boulder, CSM, or CSU) for analysis. |
| UIC | Form: (31) 2493423 07/02/2015 | A water analysis to include TDS, major cations, and major anions is required 1- year after initial injection and from then on at 5-year intervals. Water analyses should be submitted via Sundry Notice and in Electronic Data Deliverable (EDD) Format. |
| UIC | Form: (04) 403286807 02/07/2023 | Total permitted injection volume is hereby raised to 40,133,012 bbls. Injection volume may not be increased further per Rule 803.f.(4). |
| UIC | Form: (04) 403286807 02/07/2023 | Maximum permitted surface injection pressure and maximum injection rate remain unchanged. |