| Permit | Form: (02) 400545814 02/10/2014 | Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage. On a multi-well pad, these open hole logs are only required on one of the first wells drilled on the pad and the Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged.
|
| Engineer | Form: (02) 400545814 02/11/2014 | Operator acknowledges the proximity of: The Walter J. Rankin Unit 2 ( API NO 123-09929), the HSR-Sekich 4-19 ( API NO 123-18716), the HSR-Sekich 3-19A ( API NO 123-18741), the HSR-Sekich 5-19 ( API NO 123-18917), the HSR-Sekich 6-19 (API NO 123-19162), the Grandview Estates (HSR) 11-19A ( API NO 123-19861), the Butch 3-19 ( API NO 123-22141), the Sekich 31-19 ( API NO 123-24813), the Sekich 32-19 ( API NO 123-24875), the Sekich 22-19 ( API NO 123-24887), the St Vrain Land Co Unit A 1 ( API NO 123-07920), the Reynolds 8-23 ( API NO 123-24350), the Reynolds 1-23 ( API NO 123-24351), the Reynolds 2-23 ( API NO 123-24352), the Reynolds Cattle CO Gas Unit 1 ( API NO 123-08180), the Reynolds Cattle CO GU True 1 ( API NO 123-11516), the HSR-Reynolds 1-24A ( API NO 123-19562), the Reynolds 5-24A ( API NO 123-20745), and the Reynolds 4-24 ( API NO 123-24156). Operator agrees to: provide mitigation option 1 or 2 (per the DJ Basin Horizontal Offset Policy) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OTHER – AS SPECIFIED BY PERMIT CONDITION”) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well. |
| Engineer | Form: (02) 400545814 02/11/2014 | Operator acknowledges the proximity of the non-operated wells: The Nick Sekich 1 ( API NO 123-08240), the Sekich Farms 19-7L ( API NO 123-17153), and the Sekich Farms 19-2L ( API NO 123-17309). Operator assures that these offsets will be remediated per the DJ Basin Horizontal Offset Policy (options 1 or 2) or operator will address this well with mitigation option 4. Operator will submit a Form 42 (“OTHER – AS SPECIFIED BY PERMIT CONDITION”) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well. |
| Engineer | Form: (02) 400545814 02/11/2014 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Comply with Rule 317.i and provide cement coverage from the bottom of the production casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
3) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
|
| Engineer | Form: (04) 402949992 03/01/2022 | Operator shall continue to monitor pressure, and report to COGCC through annual testing. If monitored well conditions meet the thresholds defined by Order 1-232 a new bradenhead test and sundry must be filed.
|
| Engineer | Form: (04) 402949992 03/01/2022 | Collect samples for laboratory analysis. Sampling will comply with Operator Guidance - Bradenhead Testing and Reporting Instructions, Appendix A: Liquid and Gas Sampling. Copies of all final laboratory analytical results will be provided to the COGCC within three months of collecting the samples
|