WELL05-123-38234HOWARD
9C-22HZ
KERR MCGEE OIL & GAS ONSHORE LP
47120
PR
5/1/2023
WATTENBERG
90750
WELD  123
SESE 27 1N67W 6
434535View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400457430
10/3/2013
1)Note surface casing setting depth change from 877’ to 1000’. Increase cement coverage accordingly and cement to surface. 2)Provide notice of MIRU via an electronic Form 42. 3)Comply with Rule 317.i and provide cement coverage from the 7” casing TD to a minimum of 200' above the Niobrara and from 200’ below Sussex to 200’ above Sussex. Verify coverage with a cement bond log. 4)Operator acknowledges the proximity of the Wagner Red VV22-8 (API# 123-16668), Wagner Red VV 22-7 (API #123-16667), Albert Sack Unit/NAV/2 (API #123-15327), Moser C Unit 1 (API #123-10488), Dorothy Sebold Unit 1 (API #123-08119), Grenemeyer 1 (API #123-07152), and UPRR 42 Pan AM K 2 (API #123-09215) wells. Operator agrees to: provide mitigation option 1, 2 or 3 (per the DJ Basin Horizontal Offset Policy) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OTHER – AS SPECIFIED BY PERMIT CONDITION”) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well.
OGLAForm: (04 )
402794659
9/13/2021
1) Operator will implement measures to capture, combust, or control emissions to protect health and safety, and to ensure that vapors and odors from subsequent well operations do not constitute a nuisance or hazard to public health, welfare and the environment. Due to proximity of building units (BUs) all blowdown gases will be controlled. 2) Prior to commencing operations, at a minimum, the operator will provide an informational sheet to the owners/occupants of BUs that are adjacent to the parcel on which the well is located. The sheet will include the operator's contact information and the nature, timing, and expected duration of the subsquent well operations.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
400457430
10/4/2013
Kerr McGee acknowledges and will comply with the COGCC Policy for Bradenhead Monitoring during Hydraulic Fracturing Treatments in the Greater Wattenberg Area dated May 29, 2012.
Drilling/Completion OperationsForm: (02 )
400457430
10/4/2013
Anti-Collision BMP Prior to drilling operations, Operator may perform an anti-collision review of existing offset wells that have the potential of being within close proximity of the proposed well. This anti-collision review may include MWD or gyro surveys and surface locations of the offset wells with included error of uncertainty per survey instrument, and compared against the proposed wellpath with its respective error of uncertainty. If current surveys do not exist for the offset wells, Operator may have gyro surveys conducted to verify bottomhole location. The proposed well may only be drilled if the anti-collision review results indicate that the risk of collision is sufficiently low as defined by the anti-collision plan, with separation factors greater than 1.5, or if the risk of collision has been mitigated through other means including shutting in wells, plugging wells, increased drilling fluid in the event of lost returns or as is appropriate for the specific situation. In the event of an increased risk of collision, that risk will be mitigated to prevent harm to people, the environment or property. For the proposed well, upon conclusion of drilling operations, an as-constructed directional survey will be submitted to COGCC with the Form 5. At the time of permitting, the operator has identified the following well(s) as being within close proximity of the proposed well: Dry Creek 16-27