Permit | Form: (02 ) 400348691 12/7/2012 | Operator must meet water well testing requirements per Rule 318A.
|
Engineer | Form: (02 ) 400348691 12/17/2012 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Comply with Rule 317.i and provide cement coverage from end of 7” casing to a minimum of 200' above Niobrara and from 200’ below Shannon to 200’ above Sussex. Verify coverage with cement bond log.
3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
|
Engineer | Form: (04 ) 402061425 6/10/2019 | Operator to collect bradenhead gas sample and submit results to the COGCC via Form 43. |
Permit | Form: (04 ) 402440015 7/9/2020 | Operator will run cased hole neutron and gamma ray logs, or other petrophysical log(s) approved by the Director, on the first well on this pad to undergo subsequent operations that provide wireline access to the wellbore. |
Engineer | Form: (04 ) 402618824 3/15/2021 | Operator shall continue to monitor pressure, and report to COGCC through annual testing. If monitored well conditions meet the thresholds defined by Order 1-232 a new bradenhead sundry must be filed.
|
Environmental | Form: (04 ) 402637160 3/24/2021 | If samples are not able to be collected the operator shall provide a Sundry Notice explaining why the samples were not collected. The samples or Sundry Notice shall be provided to the COGCC by September 1, 2021.
|