| Agency | Form: (02) 400055242 06/01/2010 | 1) Provide 24 hour notice of MIRU to Jim Precup at 303-469-1902 or e-mail at james.precup@state.co.u 2) Set at least 1010’ of surface casing per Rule 317A, cement to surface. 3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 4) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure wellbore complies with setback requirements in commission orders or rules prior to producing the well. |
| Agency | Form: (02) 400055242 06/14/2010 | 1) Provide 24 hour notice of MIRU to Jim Precup at 303-469-1902 or e-mail at james.precup@state.co.u
2) Set at least 1010’ of surface casing per Rule 317A, cement to surface.
3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
4) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure wellbore complies with setback requirements in commission orders or rules prior to producing the well. |
| Engineer | Form: (06) 400810372 04/06/2015 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
|
| Engineer | Form: (06) 400891206 10/09/2015 | Note changes to plugging procedure:
1) Provide 48 hour notice of plugging MIRU via electronic Form 42.
|