Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-23845LUDWIG
22-1
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
12/11/2018
WATTENBERG
90750
WELD  123
SENW 1 3N66W 6
336569View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400710357
11/12/2014
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) If unable to pull casing contact COGCC for plugging modifications. 3) For 1280' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 581’ or shallower. 4) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 5) Please submit gyro survey data with Form 6 (s) Subsequent Report of Abandonment.
EngineerForm: (04)
400751507
12/16/2014
The additional cement referenced shall be placed as indicated and comply with Rule 317.j. The placed cement shall be verified with a CBL and documented with a Form 5 Drilling Completion Report.
EngineerForm: (06)
401514439
04/03/2018
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) Properly abandon all flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 3) Operator shall implement measures to control unnecessary and excessive venting, to protect the health and safety of the public, and to ensure that vapors and odors from well plugging operations do not constitute a nuisance or hazard to public welfare. 4) Bradenhead samples were collected 01/12/2018. Submit copies of all final laboratory analytical results to the COGCC within three months of collecting the samples. 5) After pumping squeeze, shut down and shut well in at minimum 8 hours; verify gas migration has been eliminated. If evidence of gas migration or pressure remains contact COGCC Engineer for an update to plugging orders.
 
COGIS - Best Management Practice Results
No records to display.