Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-07298MARGARET TWOMBLY
1
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
6/20/2014
WATTENBERG
90750
WELD  123
NESW 9 2N66W 6
317583View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
2591293
01/14/2011
1) No cement bond log on file with COGCC verifying cement through DV tool at 958' - submit cement bond log verifying cement coverage.
EngineerForm: (06)
400610330
05/20/2014
Note change in plugging procedure: 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For 5130' plug-increase TOC of cement in pipe from planned 4450' to 4180' to cover squeeze perfs@4200'. Adjust cement volume accordingly. 3) If unable to pull casing contact COGCC for plugging modifications. 4) For 400’ plug: pump plug and displace, WOC 4hours then tag plug – must be 165’ or shallower and provide 10 sx plug at the surface. Leave at least 100’ cement in the casing for each plug. 5) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
 
COGIS - Best Management Practice Results
No records to display.