Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-121-11087SHOTGUN
1
IMPETRO RESOURCES LLC
10690
PR
6/1/2023
WILDCAT
99999
WASHINGTON  121
SWSE 9 3S50W 6
466338View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
401775851
12/17/2018
Note changes to submitted form. 1) Provide 48 hour notice prior to spud via electronic Form 42. 2) Provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) If dry hole, set 40 sks cement at top of D-Sand, 40 sks cement at top of NBRR, 40 sks cement across any DST w/ show, 50 sks cement ½ out, ½ in surface casing, 15 sks cement top of surface casing, cut 4’ below GL, weld on plate, 5 sks cement in rat hole & 5 sks cement in mouse hole.
EngineerForm: (02 )
401775851
12/17/2018
Bradenhead tests shall be performed and reported according to the following schedule and Form 17 submitted within 10 days of each test.: 1) All: Within 60 days of rig release, prior to stimulation. If any pressure greater than 200 psi, must contact COGCC engineer prior to stimulation. 2) Delayed completion: 6 months after rig release, prior to stimulation. If any pressure greater than 200 psi, must contact COGCC engineer prior to stimulation. 3) A post-production test within 60 days after first sales, as reported on the Form 10, Certificate of Clearance.
EnvironmentalForm: (04 )
402224577
12/27/2019
Provide a location drawing showing the land application area.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
401775851
8/9/2019
Rule 317.p Logging Open hole resistivity log with gamma ray will be run on this well to describe the stratigraphy of the wellbore and to adequately verify the setting depth of the surface casing and aquifer coverage. A CBL will be run on all production casing or, in the case of a production liner, the intermediate casing, when these casing strings are run.
Drilling/Completion OperationsForm: (02 )
401775851
8/9/2019
Rule 604.c.(2)L. Closed chamber drill stem tests shall be allowed. All other drill stem tests shall require approval by the Director. DST's are planned for this well and results will be submitted with the Form 5 Completion Report (this will not be a closed chamber DST).
Drilling/Completion OperationsForm: (02 )
401775851
8/9/2019
Rule 604.c.(2).O. Drilling and Completion-All loadlines shall be bullplugged or capped.