COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
PermitForm: (02 )
400131271
2/14/2011
Wellhead is 140' to the nearest aboveground utility and the rig height is given as 110'. The rig used to drill the subject well must not have a derrick height of greater than 2/3rds of 140 feet or 93 feet. The minimum setback shall be achieved per the operator for a 110’ rig by laying down the power lines while conducting drilling operations. plg.
EngineerForm: (02 )
400131271
2/17/2011
(1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. (2) THE PROPOSED SURFACE CASING IS MORE THAN 50’ BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1-MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST DEDICATED* WATER WELL WITHIN 1-MILE IS 00 FEET DEEP. *(Intended for agriculture or drinking)
EngineerForm: (02 )
400237211
1/9/2012
1)COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. 2)THE PROPOSED SURFACE CASING IS MORE THAN 50' BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST WATER WELL WITHIN 1 MILE IS 000 FEET DEEP.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
400237211
1/31/2012
CLOSED LOOP SYSTEM WILL BE IMPLEMENTED DURING DRILLING, WATER BASED MUD.
Site SpecificForm: (02 )
400237211
1/31/2012
THIS WELL SITE WAS SELECTED TO UTILIZE ONE LOCATION FOR 2 DIRECTIONLY DRILLED WELLS. THIS LOCATION IS LOCATEDALON EXISTING LEASE ROAD.
ConstructionForm: (02 )
400237211
1/31/2012
THE CUTTING PITS WILL BE CONSTRUCTED TO BLM GOLD BOOK STANDARDS, NO PORTION OF THE PIT WILL BE CONSTRUCTED ON ANY FILL MATERIAL, THE ENTIRE BASE OF THE PIT WILL BE IN THE CUT.
Storm Water/Erosion ControlForm: (02 )
400237211
1/31/2012
TOP SOIL SALVAGE AND STORAGE WILL BE WHERE NO VEHICLE TRAFFIC WILL CROSS THE MOUND. WATTLES, DRAINAGE DITCHES AND DIVERSION DITCHES WILL BE CONSTRUCTED IF NEED TO CONTROL EROSION AND STORM WATER RUN OFF.