Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06316MCLAUGHLIN, A C
44
SCOUT ENERGY MANAGEMENT LLC
10779
SI
7/1/2024
RANGELY
72370
RIO BLANCO  103
SESW 11 2N103W 6
311810View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04 )
400694273
9/24/2014
1) If cement does not return to surface during liner cementing, run CBL to verify cement top is above holes in casing. Submit cement summary and/or CBL with Form 5.
UICForm: (04 )
401806314
3/22/2019
Confirmed UIC Disposal in Navajo. No change in overall gross perforated interval. Report added perforations and acid treatment on Form 5A with Frac Focus filled out.
UICForm: (04 )
401806314
3/22/2019
Pass MIT prior to return to injection.
EngineerForm: (04 )
401965433
4/18/2019
Tracer indicates top perf and packers O.K.-API included on attachment.
 
COGIS - Best Management Practice Results
No records to display.