Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-067-09838TIFFANY 2
3
HILCORP ENERGY COMPANY
10133
PR
12/14/2010
IGNACIO BLANCO
38300
LA PLATA  067
SESE 2 32N7W N
325466View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400088575
09/21/2010
There is a PA well within a ¼ mile of this proposed well. To finish my review of the APD, a PA risk assessment is required. Refer to Cause 112 - Order 185
AgencyForm: (02)
400088575
09/27/2010
1)Provide 48 hour notice of spud to COGCC field inspector Leslie Melton (970) 375-6419 or les.melton@state.co.us 2)Provide cement coverage of production casing from TD to surface. Verify cement coverage with Cement Bond Log. 3)Run and submit Directional Survey from TD to kick-off point 4)The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the well bore complies with setback requirements in Commission orders and/or rules prior to producing the well. 5)Sample and test two closest water wells within 1/2 mile swath of the directional wellbore. 6)Operators are required to obtain a bottom hole pressure utilizing a bottom hole gauge after a minimum 48 hour shut-in period following completion and prior to sales 7)Comply with all applicable provisions of Order 112-185
EngineerForm: (02)
400088575
09/27/2010
THE PA ASSESSMENT HAS BEEN RECEIVED AND REVIEWED AND APPROVED.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
WildlifeForm: (02 )
400088575
9/30/2010
Attached
Site SpecificForm: (02 )
400088575
9/30/2010
Attached