| Engineer | Form: (02) 400391264 08/01/2013 | (1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED.
(2) INTERMEDIATE CASING CEMENT SHALL EXTEND FROM THE INTERMEDIATE CASING SHOE TO 200’ ABOVE THE SURFACE CASING SHOE. INTERMEDIATE CASING CEMENT COVERAGE VERIFICATION BY CBL IS REQUIRED.
(3) OPEN-HOLE CEMENT ISOLATION PLUGS SHALL BE SET IN THE PILOT HOLE (00 WELLBORE) FROM THE DAKOTA GROUP TOP TO 100’ ABOVE THE DAKOTA GROUP TOP AND FROM THE FRONTIER FORMATION TOP TO 100’ ABOVE THE FRONTIER FORMATION TOP, IN ADDITION TO THE LATERAL KICK-OFF PLUG IN THE NIOBRARA FORMATION. |
| Engineer | Form: (02) 400396766 08/01/2013 | (1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED.
(2) OPEN-HOLE CEMENT ISOLATION PLUGS SHALL BE SET IN THE PILOT HOLE (00 WELLBORE) FROM THE DAKOTA GROUP TOP TO 100’ ABOVE THE DAKOTA GROUP TOP AND FROM THE FRONTIER FORMATION TOP TO 100’ ABOVE THE FRONTIER FORMATION TOP, IN ADDITION TO THE LATERAL KICK-OFF PLUG IN THE NIOBRARA FORMATION. |
| Permit | Form: (02) 400396766 09/19/2013 | Rig height (ground to crown) cannot exceed 131'. |
| Permit | Form: (02) 400391264 09/19/2013 | Rig height (ground to crown) cannot exceed 131'. |
| Engineer | Form: (04) 400806974 03/10/2015 | 1) Operator shall provide cement coverage from the production casing shoe (5+1/2" First String) to a minimum of 200' above the surface casing shoe to provide full isolation of the Coalmont Formation. Verify production casing cement coverage with a cement bond log. |
| Engineer | Form: (04) 400922636 11/10/2015 | 1) Comply with all requirements of Rule 912, including monthly reporting of flared volumes (on Form 7) and notifications to local emergency dispatch or the local government designee.
2) Submit annual updates (requests to flare) to COGCC on Form 4’s (Sundry Notices), which discuss whether or not any new gathering systems or increased development of the field have changed pipeline economics such that installation of a new pipeline would be an economically viable option in lieu of continued flaring. The annual update shall include gas analysis for hydrogen sulfide.
3) Comply with any Colorado Department of Public Health and Environment, Air Pollution Control Division rules or requirements for all atmospheric discharges.
4) An enclosed flare shall be used, unless an open flare is specifically allowed by CDPHE’s Regulation 7. |
| Environmental | Form: (04) 401103131 09/06/2016 | The vertical and horizontal extent of impact should be determined through the soil investigation. Soil samples should be taken as depths containing native material and suspected to be non-impacted. |
| Environmental | Form: (04) 401103131 09/06/2016 | The location of proposed samples are adequate, in the event that the “step out” samples indicate the extent of impacted material has not been reached, soil boring should be advanced until no impact is proven (vertically and laterally).. |
| Environmental | Form: (04) 401103131 09/06/2016 | Request for Closure will NOT be approved without Operator providing notice to Environmental staff, Kris Neidel (kris.neidel@state.co.us) or 970-871-1963 72hrs prior to mobilization at begin of work. |
| Environmental | Form: (04) 401103131 09/06/2016 | Reclamation should comply with 1000 series rules. |
| Environmental | Form: (04) 401103131 09/06/2016 | COGCC should be notified immediately, in the event that groundwater is encountered in investigation. |
| Environmental | Form: (04) 401103131 09/06/2016 | In the event that Monitoring wells are installed, the screened interval should be such that it intersects the surface of ground water. |
| Environmental | Form: (04) 401103131 09/06/2016 | Work plan is approved; however additional information and remediation may be required during the course of investigation and remediation. |
| Environmental | Form: (04) 401131327 10/19/2016 | It is stated that “Following treatment, the soil will need to be allowed to sit for a minimum of 24 hours prior to confirmation soil sampling to ensure that chemical reactions were complete and equilibrium in soil is established. LTE, under the direction of SandRidge, will collect one 20-point composite confirmation soil sample representative of each approximately 100 cubic yard interval. Each composite sample shall be field screened using a PID and a Petroflag kit (or equivalent, to verify the reduction in VOCs prior to laboratory analysis.”Each composite confirmation sample shall be analyzed for BTEX, TPH-GRO, TPH-DRO. |
| Environmental | Form: (04) 401131327 10/19/2016 | • Reclamation shall be in accordance to the COGCC’s 900 and 1000 Series Rules. |
| Environmental | Form: (04) 401131327 10/19/2016 | • Within 30-days of this Sundry approval, provide which remedial option will be implemented and a schedule of when remedial activities will commence. |
| Environmental | Form: (04) 401131327 10/19/2016 | • COGCC should be notified immediately, in the event that groundwater is encountered during remedial activities. If groundwater is encountered a sample shall be obtained for chemical analyses. |
| Environmental | Form: (04) 401131327 10/19/2016 | • Storm water controls should be implemented around the E&P Waste and treatment area(s) to prevent storm water run on and run off. |
| Environmental | Form: (04) 401131327 10/19/2016 | • Request for Closure will NOT be approved without Operator providing notice to Environmental staff, Kris Neidel (kris.neidel@state.co.us) or 970-871-1963 72hrs prior to mobilization at start of work. |
| Environmental | Form: (04) 401131327 10/19/2016 | • On future submittals under Well/Location, use Location ID: 33288and reference 9816. |
| Environmental | Form: (04) 401131327 10/19/2016 | • Conditionally approved, however, additional information or activities may be required during the course of remediation. |
| Environmental | Form: (04) 401144422 11/29/2016 | Sandrige should visually monitor the cuttings burial areas for any observable impacts until remediation has begun. |
| Engineer | Form: (04) 401158161 01/05/2017 | 1) Comply with all requirements of Rule 912, including monthly reporting of flared volumes (on Form 7) and notifications to local emergency dispatch or the local government designee.
2) Submit annual updates (requests to flare) to COGCC on Form 4s (Sundry Notices),including all information specified in COGCC’s "Notice to Operators, Rule 912 Venting or Flaring Produced Natural Gas - Statewide."
3) Comply with any Colorado Department of Public Health and Environment, Air Pollution Control Division rules or requirements for all atmospheric discharges.
4) An enclosed flare shall be used, unless an open flare is specifically allowed by CDPHE’s Regulation 7.
5) By 8/31/2017: collect a new gas sample for laboratory analysis including hydrogen sulfide and submit a new Form 4 with the laboratory results. Analysis attachments to the new Form 4 shall be a PDF copy of the laboratory data sheet and an Electronic Data Deliverable (EDD) prepared by the laboratory in the format specified on COGCC’s website, located in Help => Environmental => COGCC EDD Information. |
| Engineer | Form: (04) 401423715 10/18/2017 | 1) Comply with all requirements of Rule 912, including monthly reporting of flared volumes (on Form 7) and notifications to local emergency dispatch or the local government designee.
2) Submit annual updates (requests to flare) to COGCC on Form 4s (Sundry Notices),including all information specified in COGCC’s "Notice to Operators, Rule 912 Venting or Flaring Produced Natural Gas - Statewide."
3) Comply with any Colorado Department of Public Health and Environment, Air Pollution Control Division rules or requirements for all atmospheric discharges.
4) An enclosed flare shall be used, unless an open flare is specifically allowed by CDPHE’s Regulation 7.
5) With next years annual update (request to flare), collect a new gas sample including hydrogen sulfide and submit an Electronic Data Deliverable (EDD), prepared by the laboratory that performed the gas analysis. The EDD shall be submitted with the annual update, in the format specified on COGCC’s website, located in Help => Environmental => COGCC EDD Information.
|
| Engineer | Form: (04) 401833563 03/06/2019 | 1) Comply with all requirements of Rule 912, including monthly reporting of flared volumes (on Form 7) and notifications to local emergency dispatch or the local government designee.
2) Submit annual updates (requests to flare) to COGCC on Form 4s (Sundry Notices), including all information specified in COGCC’s "Notice to Operators, Rule 912 Venting or Flaring Produced Natural Gas - Statewide."
3) Comply with any Colorado Department of Public Health and Environment, Air Pollution Control Division rules or requirements for all atmospheric discharges.
4) An enclosed flare shall be used, unless an open flare is specifically allowed by CDPHE’s Regulation 7.
5) With the next annual update (request to flare), collect a new gas sample for laboratory analysis including hydrogen sulfide and submit a Form 43 to upload the laboratory results to the COGCC Environmental Database. Form 43 instructions are on COGCC’s website under Regulation => Forms => Form 43 COGCC Environmental Database.
|